{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T17:01:28Z","timestamp":1791219688031,"version":"4.1.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2009,4,15]],"date-time":"2009-04-15T00:00:00Z","timestamp":1239753600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2009,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We extended an earlier study (Vision Research, 45, 1967\u20131974, 2005) in which we investigated limits at which induced blur of letter targets becomes noticeable, troublesome and objectionable. Here we used a deformable adaptive optics mirror to vary spherical defocus for conditions of a white background with correction of astigmatism; a white background with reduction of all aberrations other than defocus; and a monochromatic background with reduction of all aberrations other than defocus. We used seven cyclopleged subjects, lines of three high\u2010contrast letters as targets, 3\u20136\u2003mm artificial pupils, and 0.1\u20130.6\u2003logMAR letter sizes. Subjects used a method of adjustment to control the defocus component of the mirror to set the \u2018just noticeable\u2019, \u2018just troublesome\u2019 and \u2018just objectionable\u2019 defocus levels. For the white\u2010no adaptive optics condition combined with 0.1\u2003logMAR letter size, mean \u2018noticeable\u2019 blur limits were \u00b10.30, \u00b10.24 and \u00b10.23\u2003D at 3, 4 and 6\u2003mm pupils, respectively. White\u2010adaptive optics and monochromatic\u2010adaptive optics conditions reduced blur limits by 8% and 20%, respectively. Increasing pupil size from 3\u20136\u2003mm decreased blur limits by 29%, and increasing letter size increased blur limits by 79%. Ratios of troublesome to noticeable, and of objectionable to noticeable, blur limits were 1.9 and 2.7 times, respectively. The study shows that the deformable mirror can be used to vary defocus in vision experiments. Overall, the results of noticeable, troublesome and objectionable blur agreed well with those of the previous study. Attempting to reduce higher\u2010order aberrations or chromatic aberrations, reduced blur limits to only a small extent.<\/jats:p>","DOI":"10.1111\/j.1475-1313.2009.00637.x","type":"journal-article","created":{"date-parts":[[2009,4,15]],"date-time":"2009-04-15T05:39:29Z","timestamp":1239773969000},"page":"300-311","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Limits of spherical blur determined with an adaptive optics mirror"],"prefix":"10.1007","volume":"29","author":[{"given":"David A.","family":"Atchison","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanqing","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott W.","family":"Fisher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,4,15]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"American National Standard for Ophthalmics \u2013 Methods for Reporting Optical Aberrations of the Eye","author":"American National Standards Institute","year":"2004"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.4"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.01.022"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197611000-00006"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.001438"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.0401440101"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.23.000001"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1167\/7.10.9"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0997"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.10.004"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1080\/09500340701469641"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-1422"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1364\/OE.14.008900"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199707000-00021"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001003"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2008.04.033"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.2414-05.2005"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1167\/5.5.5"},{"key":"e_1_2_6_20_1","volume-title":"Ophthalmic Optics and Instruments \u2013 Reporting Aberrations of the Human Eye","author":"International Standards Organisation","year":"2008"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.14.002884"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1195"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1167\/8.2.5"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0234"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.08.001"},{"key":"e_1_2_6_26_1","first-page":"118","article-title":"Comparison of the depths of focus with the naked eye and with three types of presbyopic contact lens correction","volume":"18","author":"Plakitsi A.","year":"1993","journal-title":"J. Br. Contact Lens Assoc."},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20071101-17"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1038\/17383"},{"key":"e_1_2_6_29_1","volume-title":"Safety of Laser Products","author":"Standards Australia\/Standards New Zealand","year":"2004"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2004.00250.x"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2005.11.003"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2006.04.005"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.01.056"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.000266"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2009.00637.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2009.00637.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:29Z","timestamp":1767785129000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2009.00637.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4,15]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,5]]}},"alternative-id":["10.1111\/j.1475-1313.2009.00637.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2009.00637.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,15]]},"assertion":[{"value":"2009-04-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}