{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T10:42:17Z","timestamp":1791196937197,"version":"4.1.0"},"reference-count":66,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2009,8,4]],"date-time":"2009-08-04T00:00:00Z","timestamp":1249344000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2009,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:bold>Purpose:\u2002<\/jats:bold>\n                    To provide a model of an aberration\u2010free profile and to clinically evaluate the impact of treatments based upon these theoretical profiles in the post\u2010operative cornea.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    Aberration\u2010free profiles were deduced from the Zernike expansion of the difference between two corneal cartesian\u2010ovals. Compensation for the focus\u2010shift effects of removing corneal tissue were incorporated by preserving the location of the optical focus of the anterior corneal surface. Simulation of the surgical performance of the profile was performed by means of simulated ray\u2010tracing through a cornea described by its anterior surface and pachymetry. Clinical evaluation was retrospectively analysed in terms of visual outcomes, corneal wavefront aberration and asphericity changes at 3\u2010month follow\u2010up compared to the baseline on 100 eyes treated for compound myopic astigmatism.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    The proposed \u2018aberration\u2010free\u2019 profiles theoretically preserve aberrations, becoming more oblate asphericity after myopic treatments, and more prolate after hyperopic ones. In the clinical evaluation, 94% of eyes were within \u00b10.50\u2003D of emmetropia. BSCVA improved significantly (\n                    <jats:italic>p\u2003<\/jats:italic>\n                    &lt;\u20030.001). Induced corneal aberrations at 6\u2010mm were below clinically relevant levels: 0.123\u2003\u00b1\u20030.129\u2003\u03bcm for HO\u2010RMS (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.001), 0.065\u2003\u00b1\u20030.128\u2003\u03bcm for spherical aberration (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.001) and 0.058\u2003\u00b1\u20030.128\u2003\u03bcm for coma (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.01), whereas the rate of induced aberrations per achieved D of correction were \u22120.042, \u22120.031, and \u22120.030\u2003\u03bcm\u2003D\n                    <jats:sup>\u22121<\/jats:sup>\n                    for HO\u2010RMS, SphAb, and coma (all\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.001). Induction of positive asphericity correlated to achieved correction (\n                    <jats:italic>p\u2003<\/jats:italic>\n                    &lt;\u20030.001) at a rate 3\u00d7 theoretical prediction.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:\u2002<\/jats:bold>\n                    \u2018Aberration\u2010free\u2019 patterns for refractive surgery as defined here together with consideration of other sources of aberrations such as blending zones, eye\u2010tracking, and corneal biomechanics yielded results comparable to those of customisation approaches. Having close\u2010to\u2010ideal profiles should improve clinical outcomes decreasing the need for nomograms, and diminishing induced aberrations after surgery.\n                  <\/jats:p>","DOI":"10.1111\/j.1475-1313.2009.00670.x","type":"journal-article","created":{"date-parts":[[2009,8,4]],"date-time":"2009-08-04T05:49:12Z","timestamp":1249364952000},"page":"535-548","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":52,"title":["Analysis of optimized profiles for \u2018aberration\u2010free\u2019 refractive surgery"],"prefix":"10.1007","volume":"29","author":[{"given":"Samuel","family":"Arba\u2010Mosquera","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"De Ortueta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,8,4]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"crossref","first-page":"516","DOI":"10.3928\/1081-597X-20030901-06","article-title":"Topography\u2010guided laser in situ keratomileusis (TOPOLINK) to correct irregular astigmatism after previous refractive surgery","volume":"19","author":"Alio J. L.","year":"2003","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01895-3"},{"key":"e_1_2_6_4_1","doi-asserted-by":"crossref","first-page":"295","DOI":"10.3928\/1081-597X-19970501-16","article-title":"Refractive surgery, optical aberrations, and visual performance","volume":"13","author":"Applegate R. A.","year":"1997","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091016-04"},{"key":"e_1_2_6_6_1","unstructured":"Artal P.(2005)What aberration pattern (if any) produces the best vision? presented at the6th International Wavefront Congress February Athens Greece."},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.4"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1088\/0959-5309\/55\/5\/302"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.20.000001"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02181196"},{"key":"e_1_2_6_11_1","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081-597X-20040701-11","article-title":"Limitations of pupil tracking in refractive surgery: systematic error in determination of corneal locations","volume":"20","author":"Bueeler M.","year":"2004","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_12_1","doi-asserted-by":"crossref","first-page":"28","DOI":"10.3928\/1081-597X-20050101-08","article-title":"Simulation of eye\u2010tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems","volume":"21","author":"Bueeler M.","year":"2005","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.098"},{"key":"e_1_2_6_14_1","volume-title":"The Optical Quality of the Cornea","author":"Calossi A.","year":"2002"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01541-9"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1038\/254663a0"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1080\/09500340308235245"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.046"},{"key":"e_1_2_6_19_1","first-page":"941","article-title":"Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity","volume":"43","author":"Gatinel D.","year":"2002","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0753"},{"key":"e_1_2_6_21_1","unstructured":"Gauss C. F.(1823) Theoria combinationis obsevationum erroribus minimis obnoxiae."},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.17.000955"},{"key":"e_1_2_6_23_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3928\/1081-597X-20030101-04","article-title":"Effect of beam size on the expected benefit of customized laser refractive surgery","volume":"19","author":"Guirao A.","year":"2003","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.09.008"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01324-X"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01163-4"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1502192"},{"key":"e_1_2_6_28_1","first-page":"29","article-title":"Predicting changes in corneal asphericity after hyperopic LASIK","volume":"2003","author":"Jim\u00e9nez J. R.","year":"2003","journal-title":"J. Cataract Refract. Surg."},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1364\/OPEX.13.000336"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1080\/713820960"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2008.22.3.164"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.08.035"},{"key":"e_1_2_6_34_1","doi-asserted-by":"crossref","first-page":"740","DOI":"10.3928\/1081-597X-20021101-13","article-title":"Thirty\u2010four challenges to meet before excimer laser technology can achieve super vision","volume":"18","author":"Lipshitz I.","year":"2002","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01322-0"},{"key":"e_1_2_6_36_1","doi-asserted-by":"crossref","first-page":"S596","DOI":"10.3928\/1081-597X-20010901-19","article-title":"Aberrations and visual performance following standard Laser vision correction","volume":"17","author":"Marcos S.","year":"2001","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_37_1","first-page":"3349","article-title":"Optical response to LASIK surgery for myopia from total and corneal aberration measurements","volume":"42","author":"Marcos S.","year":"2001","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_38_1","doi-asserted-by":"crossref","first-page":"S592","DOI":"10.3928\/1081-597X-20030901-17","article-title":"Increase in corneal asphericity after standard laser in situ keratomileusis for myopia is not inherent to the Munnerlyn algorithm","volume":"19","author":"Marcos S.","year":"2003","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.11.026"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199711000-00021"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1038\/417174a"},{"key":"e_1_2_6_42_1","doi-asserted-by":"crossref","first-page":"584","DOI":"10.3928\/1081-597X-20010901-15","article-title":"Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery","volume":"17","author":"Mrochen M.","year":"2001","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_43_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00827-0"},{"key":"e_1_2_6_44_1","doi-asserted-by":"crossref","first-page":"104","DOI":"10.3928\/1081-597X-20030301-04","article-title":"Correlation between corneal and total wavefront aberrations in myopic eyes","volume":"19","author":"Mrochen M.","year":"2003","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_2_6_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"e_1_2_6_47_1","doi-asserted-by":"crossref","first-page":"322","DOI":"10.3928\/1081597X-20080401-01","article-title":"The Carriazo\u2010Pendular microkeratome creates a planar flap","volume":"24","author":"De Ortueta D.","year":"2008","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_48_1","doi-asserted-by":"crossref","first-page":"198","DOI":"10.3928\/1081-597X-20070201-13","article-title":"Centration on the cornea vertex normal during hyperopic refractive photoablation using videokeratoscopy","volume":"23","author":"De Ortueta D.","year":"2007","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_49_1","doi-asserted-by":"crossref","first-page":"366","DOI":"10.3928\/1081-597X-19930901-08","article-title":"Model for predicting the optical performance of the eye in refractive surgery","volume":"9","author":"Patel S.","year":"1993","journal-title":"Refract. Corneal Surg."},{"key":"e_1_2_6_50_1","unstructured":"P\u00e9rez\u2010Escudero A. Dorronsoro C.andMarcos S.(2009)An artifact in fits to conic\u2010based surfaces. E\u2010pub only: arXiv:0905.0814v1."},{"key":"e_1_2_6_51_1","first-page":"S678","article-title":"Correlation of wavefront data and corneal asphericity with contrast sensitivity after laser in situ keratomileusis for myopia","volume":"20","author":"Pop M.","year":"2004","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_52_1","unstructured":"Salmon T. O.(1999) Corneal contribution to the wavefront aberration of the eye.PhD Dissertation Bloomington IN: Indiana University; 70."},{"key":"e_1_2_6_53_1","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070301-07"},{"key":"e_1_2_6_54_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1989.tb00899.x"},{"key":"e_1_2_6_55_1","doi-asserted-by":"crossref","first-page":"S581","DOI":"10.3928\/1081-597X-20040901-32","article-title":"Corneal asphericity and retinal image quality: a case study and simulations","volume":"20","author":"Somani S.","year":"2004","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_56_1","doi-asserted-by":"crossref","first-page":"746","DOI":"10.3928\/1081-597X-20061001-04","article-title":"Customized LASIK treatment for myopia: relationship between preoperative high order aberrations and refractive outcome","volume":"22","author":"Subbaram M. V.","year":"2006","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_57_1","doi-asserted-by":"crossref","first-page":"S652","DOI":"10.3928\/1081-597X-20020901-30","article-title":"VSIA standards taskforce members, \u2018standards for reporting the optical aberrations of eyes\u2019","volume":"18","author":"Thibos L. N.","year":"2002","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_58_1","first-page":"329","article-title":"Accuracy and precision of objective refraction from wavefront aberrations","volume":"4","author":"Thibos L.","year":"2004","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_59_1","first-page":"S961","article-title":"Higher order aberrations comparison in fellow eyes following intraLase LASIK with wavelight allegretto and customcornea LADArvision4000 systems","volume":"22","author":"Tran D. B.","year":"2006","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.037"},{"key":"e_1_2_6_61_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00328-4"},{"key":"e_1_2_6_62_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.002"},{"key":"e_1_2_6_63_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232227.70122.b5"},{"key":"e_1_2_6_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32127-4"},{"key":"e_1_2_6_65_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.046"},{"key":"e_1_2_6_66_1","doi-asserted-by":"publisher","DOI":"10.1093\/mnras\/94.5.377"},{"key":"e_1_2_6_67_1","doi-asserted-by":"crossref","first-page":"573","DOI":"10.3928\/1081-597X-20070601-07","article-title":"Corneal wavefront\u2010guided ablation with the Schwind ESIRIS laser for myopia","volume":"23","author":"Zhou C.","year":"2007","journal-title":"J. Refract. Surg."}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2009.00670.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2009.00670.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:35Z","timestamp":1767785135000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2009.00670.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,8,4]]},"references-count":66,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["10.1111\/j.1475-1313.2009.00670.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2009.00670.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,8,4]]},"assertion":[{"value":"2009-08-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}