{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T16:18:05Z","timestamp":1776183485649,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2010,4,7]],"date-time":"2010-04-07T00:00:00Z","timestamp":1270598400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2010,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:bold>Purpose:\u2002<\/jats:bold>\n                    To report the clinical results of the use of the YK contact lens (Lucid Co., Seoul, Korea) for keratoconus.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    One hundred and twenty nine keratoconic eyes were fitted with a YK lens which has one base curve and three peripheral curves. A light feather touch fluorescein pattern was obtained based on topographic indices. Visual acuity, comfort, mean wearing time, and ocular tissue changes were evaluated. Mean follow up was 17.5\u2003\u00b1\u200313.8\u2003months (range 6\u201375).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    One hundred and twenty six (97.6%) eyes tolerated the contact lenses. A total of 94.5% of the eyes achieved a visual acuity of 20\/40 or better (average 0.79\u2003\u00b1\u20030.21), and flatter base curve radius (BCR) was related to better visual acuity. One hundred and seventeen (90.7%) eyes reported that the lenses were comfortable. Mean wearing time was 12.1\u2003h per day (range 4\u201318). Changes in keratometric values were not significant between baseline and final follow\u2010up visit.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:\u2002<\/jats:bold>\n                    The YK lens can provide successful visual outcome, with comfort, and no significant influence on the progression of keratoconus.\n                  <\/jats:p>","DOI":"10.1111\/j.1475-1313.2010.00724.x","type":"journal-article","created":{"date-parts":[[2010,4,7]],"date-time":"2010-04-07T06:18:10Z","timestamp":1270621090000},"page":"267-273","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["The effect of the YK lens in keratoconus"],"prefix":"10.1007","volume":"30","author":[{"given":"Young Seok","family":"Kang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Kee","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Soo","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seung Uk","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Hun","family":"Shin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Sang","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong Jun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hee Young","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boo Sup","family":"Oum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji\u2010Eun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,4,7]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"crossref","first-page":"492","DOI":"10.3928\/1081-597X-19960501-13","article-title":"Photodocumentation of corneal scarring","volume":"12","author":"Barr J. T.","year":"1996","journal-title":"J. Refract. Surg."},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(88)33189-1"},{"key":"e_1_2_6_4_1","first-page":"493","volume-title":"Clinical manual of contact lenses Second Edition","author":"Bennett E. S.","year":"2000"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200208000-00011"},{"key":"e_1_2_6_6_1","first-page":"74","article-title":"Contact lenses in keratoconus","volume":"4","author":"Buxton J. N.","year":"1978","journal-title":"Contact Intraocul. Lens Med. J."},{"key":"e_1_2_6_7_1","first-page":"69","article-title":"Preliminary report on a new contact lens design for keratoconus","volume":"4","author":"Caroline P.","year":"1978","journal-title":"Contact Intraocul. Lens Med. J."},{"key":"e_1_2_6_8_1","first-page":"202","article-title":"Use of SoftPerm contact lenses where rigid gas permeable lenses fail","volume":"27","author":"Chung C. W.","year":"2001","journal-title":"CLAO J."},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-199805000-00006"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(92)31825-1"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199606000-00003"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199910000-00020"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200403000-00010"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.30706"},{"key":"e_1_2_6_15_1","first-page":"53","article-title":"Corneal contour change with 3M fluoropolymer lenses","volume":"2","author":"Kame R.","year":"1987","journal-title":"Contact Lens Spectrum"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(86)90817-2"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(90)32569-1"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000095230.24618.03"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0896-1549(03)00057-9"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.1999.tb06653.x"},{"key":"e_1_2_6_21_1","first-page":"57","article-title":"Long\u2010term wear of polycon contact lenses in keratoconus","volume":"9","author":"Maguen E.","year":"1983","journal-title":"CLAO J."},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000138717.57592.36"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000146321.56815.75"},{"key":"e_1_2_6_24_1","first-page":"36","article-title":"The latest lens design for keratoconus","volume":"8","author":"Patrick J. C.","year":"1997","journal-title":"Spectrum"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000148311.94180.6b"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-198602610-00014"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.118.9.1179"},{"key":"e_1_2_6_29_1","first-page":"22","article-title":"Comparison of axial and instantaneous videokeratographic data in keratoconus and utility in contact lens curvature prediction","volume":"24","author":"Szczotka L. B.","year":"1998","journal-title":"CLAO J."},{"key":"e_1_2_6_30_1","first-page":"220","article-title":"Keratocyte apoptosis: implications on corneal wound healing, tissue organization and disease","volume":"39","author":"Wilson S. E.","year":"1998","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_31_1","first-page":"205","volume-title":"Clinical Practice in Contact Lenses","author":"Zadnik K.","year":"1999"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2010.00724.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2010.00724.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:46Z","timestamp":1767785146000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2010.00724.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4,7]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,5]]}},"alternative-id":["10.1111\/j.1475-1313.2010.00724.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2010.00724.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,4,7]]},"assertion":[{"value":"2010-04-07","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}