{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T12:22:23Z","timestamp":1790338943808,"version":"4.1.0"},"reference-count":61,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2010,12,13]],"date-time":"2010-12-13T00:00:00Z","timestamp":1292198400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2011,1]]},"abstract":"<jats:sec>\n                    <jats:label\/>\n                    <jats:p>\n                      <jats:bold>Citation information:<\/jats:bold>\n                      Fortuin MF, Lambooij MT, IJsselsteijn WA, Heynderickx I, Edgar DF &amp; Evans BJW. An exploration of the initial effects of stereoscopic displays on optometric parameters.\n                      <jats:italic>Ophthalmic Physiol Opt<\/jats:italic>\n                      2011,\n                      <jats:bold>31<\/jats:bold>\n                      , 33\u201344.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>\n                      <jats:bold>Purpose:\u2002<\/jats:bold>\n                      To compare the effect on optometric variables of reading text presented in 2\u2010D and 3\u2010D on two types of stereoscopic display.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Methods:\u2002<\/jats:bold>\n                      This study measured changes in binocular visual acuity, fixation disparity, aligning prism, heterophoria, horizontal fusional reserves, prism facility and accommodation responses for near of subjects after completing ten consecutive reading tasks of 1\u2003minute each. The tasks consisted of reading words on a polarized two\u2010view (\n                      <jats:italic>n<\/jats:italic>\n                      \u2003=\u200339) and an auto\u2010stereoscopic lenticular nine\u2010view display (\n                      <jats:italic>n<\/jats:italic>\n                      \u2003=\u200319) with the text presented without or with stereoscopic disparity at 3\u2003m. Performance was assessed by measuring reading speed and symptoms were rated by the Convergence Insufficiency Symptom Survey (CISS) questionnaire.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Results:\u2002<\/jats:bold>\n                      With both types of display, CISS scores at least doubled immediately after subjects viewed the 3\u2010D text image in an extreme stereoscopic condition compared to the 2\u2010D condition (\n                      <jats:italic>p<\/jats:italic>\n                      \u2003&lt;\u20030.001), while the mean reading speed slowed (\n                      <jats:italic>p<\/jats:italic>\n                      \u2003&lt;\u20030.001). Mean changes in optometric test variables were not clinically or statistically significant (\n                      <jats:italic>p<\/jats:italic>\n                      values &gt;\u20030.05). After the 3\u2010D task one participant showed consistent clinically meaningful decreases in convergent fusional break and recovery points for both displays.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Conclusion:\u2002<\/jats:bold>\n                      When healthy adult subjects with normal binocular vision viewed text images at 3\u2003m in extreme 3\u2010D display settings for a short period of time there were no clinically significant mean changes in optometric test variables compared with 2\u2010D viewing.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/j.1475-1313.2010.00804.x","type":"journal-article","created":{"date-parts":[[2010,12,13]],"date-time":"2010-12-13T08:11:12Z","timestamp":1292227872000},"page":"33-44","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["An exploration of the initial effects of stereoscopic displays on optometric parameters"],"prefix":"10.1007","volume":"31","author":[{"given":"Marten F","family":"Fortuin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc T","family":"Lambooij","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wijnand A","family":"IJsselsteijn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ingrid","family":"Heynderickx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David F","family":"Edgar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce JW","family":"Evans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2010,12,13]]},"reference":[{"key":"e_1_2_8_2_2","first-page":"48","article-title":"Stereoscopic 3D Movies and TV are here","volume":"24","author":"Hyde Park Editorial","year":"2009","journal-title":"Binocul Vis Strabismus Q"},{"key":"e_1_2_8_3_2","first-page":"459","article-title":"Subjective measures of presence and discomfort in viewers of color\u2010seperation\u2010based stereoscopic cinema","volume":"17","author":"P\u00f6l\u00f6nen M","year":"2009","journal-title":"J of the SID"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.2352\/J.ImagingSci.Technol.2009.53.3.030201"},{"key":"e_1_2_8_5_2","first-page":"1067","volume-title":"Handbook of Optoelectronics","author":"Holliman NS","year":"2006"},{"key":"e_1_2_8_6_2","volume-title":"Presence in Depth","author":"IJsselsteijn WA","year":"2004"},{"key":"e_1_2_8_7_2","article-title":"Philips decides to shut down 3D operation","author":"Chinnock C","year":"2009","journal-title":"Display Daily"},{"key":"e_1_2_8_8_2","doi-asserted-by":"publisher","DOI":"10.1889\/1.2036616"},{"key":"e_1_2_8_9_2","doi-asserted-by":"publisher","DOI":"10.1117\/12.274456"},{"key":"e_1_2_8_10_2","doi-asserted-by":"crossref","first-page":"72","DOI":"10.3928\/0191-3913-19830301-08","article-title":"A new stereotest","volume":"20","author":"Lang J","year":"1983","journal-title":"J Ped Ophthalmol Strab"},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.displa.2009.09.001"},{"key":"e_1_2_8_12_2","first-page":"117","volume-title":"Visual Perception: New Research","author":"Rajae\u2010Joordens RJE","year":"2008"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/TCSVT.2004.823398"},{"key":"e_1_2_8_14_2","first-page":"219","volume-title":"3D Videocommunication \u2010 Algorithms, Concepts and Real\u2010Time Systems in Human\u2010Centred Communication","author":"IJsselsteijn WA","year":"2005"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1167\/8.3.33"},{"key":"e_1_2_8_16_2","first-page":"205","volume-title":"Visual Instrumentation","author":"Peli E","year":"1999"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0141-9382(96)01040-2"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2002.00061.x"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198301000-00001"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-196807000-00002"},{"key":"e_1_2_8_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.displa.2004.07.001"},{"key":"e_1_2_8_22_2","volume-title":"Pickwell\u2019s Binocular Vision Anomalies","author":"Evans BJW","year":"2007"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.07.014"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00397-0"},{"key":"e_1_2_8_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.displa.2004.07.004"},{"key":"e_1_2_8_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199810000-00018"},{"key":"e_1_2_8_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198309000-00005"},{"key":"e_1_2_8_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199301000-00009"},{"key":"e_1_2_8_29_2","volume-title":"Clinical Procedures in Optometry","author":"Eskridge JB","year":"1991"},{"key":"e_1_2_8_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-194409000-00001"},{"key":"e_1_2_8_31_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.118.5.615"},{"key":"e_1_2_8_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2010.00714.x"},{"key":"e_1_2_8_33_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2001.00575.x"},{"key":"e_1_2_8_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200312000-00014"},{"key":"e_1_2_8_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199904000-00025"},{"key":"e_1_2_8_36_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2004.00202.x"},{"key":"e_1_2_8_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181989252"},{"key":"e_1_2_8_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2008.09.005"},{"key":"e_1_2_8_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2006.00385.x"},{"key":"e_1_2_8_40_2","doi-asserted-by":"publisher","DOI":"10.1889\/1.2785530"},{"key":"e_1_2_8_41_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1996.96000282.x"},{"key":"e_1_2_8_42_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2003.00144.x"},{"key":"e_1_2_8_43_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2002.00079.x"},{"key":"e_1_2_8_44_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2002.00071.x"},{"key":"e_1_2_8_45_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1993.tb00496.x"},{"key":"e_1_2_8_46_2","first-page":"63","article-title":"Optometric prescribing for decompensated heterophoria","volume":"9","author":"Evans BJW","year":"2008","journal-title":"Optom in Practice"},{"key":"e_1_2_8_47_2","first-page":"MT1","article-title":"Measurements of objective and subjective fixation disparity with and without a central fusion stimulus","volume":"2","author":"Brautaset RL","year":"2006","journal-title":"Med Sci Monit"},{"key":"e_1_2_8_48_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2008.00583.x"},{"key":"e_1_2_8_49_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11065-006-9013-7"},{"key":"e_1_2_8_50_2","first-page":"931","article-title":"Measuring visual discomfort associated with 3D displays","volume":"18","author":"Lambooij M","year":"2010","journal-title":"J of the SID"},{"key":"e_1_2_8_51_2","first-page":"433","article-title":"Determining limits to avoid double vision in an autostereoscopic display: disparity and image element width","volume":"17","author":"H\u00e4kkinen J","year":"2009","journal-title":"J of the SID"},{"key":"e_1_2_8_52_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-6870(98)00044-1"},{"key":"e_1_2_8_53_2","doi-asserted-by":"publisher","DOI":"10.4263\/jorthoptic.16.69"},{"key":"e_1_2_8_54_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.displa.2007.09.004"},{"key":"e_1_2_8_55_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.2001.790306.x"},{"key":"e_1_2_8_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.02.019"},{"key":"e_1_2_8_57_2","first-page":"1L1","article-title":"Visually representing reality; aesthetics and accessibility aspects","volume":"7240","author":"Van Nes FL","year":"2009","journal-title":"Proceedings of the SPIE"},{"key":"e_1_2_8_58_2","volume-title":"Occhiali 3D Per La Visione Di Spettacoli Cinematografici","author":"Ministero della Salute","year":"2010"},{"key":"e_1_2_8_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(95)00018-U"},{"key":"e_1_2_8_60_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181adff42"},{"key":"e_1_2_8_61_2","doi-asserted-by":"publisher","DOI":"10.1109\/JDT.2005.858938"},{"key":"e_1_2_8_62_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199503000-00006"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2010.00804.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2010.00804.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:26:14Z","timestamp":1767785174000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2010.00804.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12,13]]},"references-count":61,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,1]]}},"alternative-id":["10.1111\/j.1475-1313.2010.00804.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2010.00804.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,12,13]]},"assertion":[{"value":"2010-12-13","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}