{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T22:44:52Z","timestamp":1771541092105,"version":"3.50.1"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2012,4,18]],"date-time":"2012-04-18T00:00:00Z","timestamp":1334707200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2012,5]]},"abstract":"<jats:sec>\n                    <jats:label\/>\n                    <jats:p>\n                      <jats:bold>Citation information:<\/jats:bold>\n                      Jinabhai A, Charman WN, O\u2019Donnell C &amp; Radhakrishnan H. Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison.\n                      <jats:italic>Ophthalmic Physiol Opt<\/jats:italic>\n                      2012,\n                      <jats:bold>32<\/jats:bold>\n                      , 200\u2013212. doi: 10.1111\/j.1475\u20101313.2012.00904.x\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>\n                      <jats:bold>Purpose:\u2002<\/jats:bold>\n                      To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically\u2010powered RGP (rigid gas\u2010permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15\u00b0) and translation (up to 1\u2003mm) from their ideal position.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Methods:\u2002<\/jats:bold>\n                      The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point\u2010spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher\u2010order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Results:\u2002<\/jats:bold>\n                      In agreement with the results of other authors, the RGP lenses markedly reduced both lower\u2010order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Conclusions:\u2002<\/jats:bold>\n                      At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/j.1475-1313.2012.00904.x","type":"journal-article","created":{"date-parts":[[2012,4,18]],"date-time":"2012-04-18T09:07:52Z","timestamp":1334740072000},"page":"200-212","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison"],"prefix":"10.1007","volume":"32","author":[{"given":"Amit","family":"Jinabhai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W","family":"Neil Charman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clare","family":"O\u2019Donnell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hema","family":"Radhakrishnan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,4,18]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31820f777b"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20071001-13"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01279-4"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702902"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2011.00889.x"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000254036.45989.65"},{"key":"e_1_2_7_8_2","first-page":"76","article-title":"Masking of irregular corneal topography with contact lenses","volume":"24","author":"Griffiths M","year":"1998","journal-title":"Cont Lens Assoc Ophthalmol J"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e3181e52dd1"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31802e64f0"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.08.004"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-1874"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1167\/9.5.6"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4558"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.000126"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001003"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1167\/3.12.38"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200309000-00008"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2009.00645.x"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31818e8eaa"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20071101-18"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.23.000769"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1364\/OL.32.001000"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1364\/OL.32.003203"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000901-12"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199303000-00011"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.23.002061"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318185280e"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00140068-200301001-00046"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2009.04.016"},{"key":"e_1_2_7_31_2","first-page":"121","article-title":"Customized correction of wavefront aberrations in abnormal human eyes by using a phase plate and a customized contact lens","volume":"49","author":"Jeong TM","year":"2006","journal-title":"J Kor Physical Soc"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199409000-00001"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199612000-00003"},{"key":"e_1_2_7_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181bc63b4"},{"key":"e_1_2_7_35_2","first-page":"173","article-title":"Correcting ocular aberrations by soft contact lenses","volume":"62","author":"L\u00f3pez\u2010Gil N","year":"2003","journal-title":"S Afr Optom"},{"key":"e_1_2_7_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-199603000-00006"},{"key":"e_1_2_7_37_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.000569"},{"key":"e_1_2_7_38_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2011.00868.x"},{"key":"e_1_2_7_39_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-1285"},{"key":"e_1_2_7_40_2","first-page":"257","article-title":"\u00c9tude des effets combin\u00e9s de la diffraction et des aberrations g\u00e9om\u00e9triques sur l\u2019image d\u2019un point lumineux","volume":"26","author":"Mar\u00e9chal A","year":"1947","journal-title":"Rev d\u2019Optique"},{"key":"e_1_2_7_41_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.002329"},{"key":"e_1_2_7_42_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.15.002563"},{"key":"e_1_2_7_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.04.017"},{"key":"e_1_2_7_44_2","doi-asserted-by":"publisher","DOI":"10.1167\/8.2.13"},{"key":"e_1_2_7_45_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200302000-00005"},{"key":"e_1_2_7_46_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-12"},{"key":"e_1_2_7_47_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.000266"},{"key":"e_1_2_7_48_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2010.00471.x"},{"key":"e_1_2_7_49_2","doi-asserted-by":"publisher","DOI":"10.1364\/AO.39.003413"},{"key":"e_1_2_7_50_2","doi-asserted-by":"publisher","DOI":"10.3921\/joptom.2010.60"},{"key":"e_1_2_7_51_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20071101-16"},{"key":"e_1_2_7_52_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200007000-00020"},{"key":"e_1_2_7_53_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200011000-00009"}],"updated-by":[{"DOI":"10.1111\/j.1475-1313.2012.00927.x","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2012,6,14]],"date-time":"2012-06-14T00:00:00Z","timestamp":1339632000000}}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2012.00904.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2012.00904.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:26:29Z","timestamp":1767785189000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2012.00904.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,18]]},"references-count":52,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["10.1111\/j.1475-1313.2012.00904.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2012.00904.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4,18]]},"assertion":[{"value":"2012-04-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}