{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T14:59:48Z","timestamp":1760799588903},"reference-count":37,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,6,25]],"date-time":"2012-06-25T00:00:00Z","timestamp":1340582400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nursing in Critical Care"],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Care bundles cluster together several evidence\u2010based practices and, in the intensive care setting, the ventilator care bundle (VCB) has been applied widely.<\/jats:p><jats:p><jats:bold>Aim:<\/jats:bold> To determine the effect of monthly feedback on VCB compliance.<\/jats:p><jats:p><jats:bold>Design:<\/jats:bold> Before and after study: primary outcome measure VCB compliance.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Data were collected for 1 year from two metropolitan general intensive care units (ICU) on one randomly allocated day per week. Baseline data from adult ventilated patients were collected during the first 6 months (phase 1). During the second 6 months (phase 2), monthly compliance data were provided to each ICU regarding both ICUs' performance.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Both \u2018all or nothing\u2019 compliance (when all four VCB elements were complied with) and overall compliance (the average compliance of the four elements) increased between the two phases. These increases were mostly small and statistically insignificant. Although both measures increased in ICU B, both fell in ICU A. ICU B's overall compliance increase was statistically significant (<jats:italic>p<\/jats:italic> = 0\u00b7005), but its \u2018all or nothing\u2019 compliance increase (19%), whilst arguably clinically significant, did not reach statistical significance. ICU B achieved increased compliance with all four VCB elements in phase 2, whereas ICU A achieved increases in two elements (deep vein thrombosis and gastric ulcer prophylaxis). Both ICUs achieved 100% compliance with gastric ulcer prophylaxis for all of phase 2. Head of bed elevation was the least complied with element in phase 1, and increased in ICU B only in phase 2.<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold> Although the compliance rates with individual elements are encouraging, the results regarding the effect of feedback on VCB compliance were variable. The finding of relatively poor compliance with head of bed elevation is consistent with previous research.<\/jats:p><jats:p><jats:bold>Recommendations:<\/jats:bold> Further research is needed to determine the effects of audit and feedback, and which strategies are most effective.<\/jats:p>","DOI":"10.1111\/j.1478-5153.2012.00519.x","type":"journal-article","created":{"date-parts":[[2012,6,25]],"date-time":"2012-06-25T13:00:11Z","timestamp":1340629211000},"page":"293-301","source":"Crossref","is-referenced-by-count":10,"title":["Effect of feedback on ventilator care bundle compliance: before and after study"],"prefix":"10.1111","volume":"17","author":[{"given":"Petra","family":"Lawrence","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Fulbrook","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,6,25]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2006.10.019"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2010.01.008"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1053\/jcrc.2002.33035"},{"key":"e_1_2_9_5_1","first-page":"195","article-title":"Improving care for the ventilated patient.","volume":"30","author":"Berenholtz SM","year":"2004","journal-title":"Joint Commission Journal on Quality and Safety"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1086\/658938"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1553-7250(06)32079-X"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.2010.69"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.mlr.0000215919.89893.8a"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijantimicag.2007.03.003"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/qshc.2009.038265"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(98)12251-1"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e318161b0c8"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1741-6787.2007.00098.x"},{"key":"e_1_2_9_15_1","first-page":"156","volume-title":"Nursing and Midwifery Research: Methods and Appraisal for Evidence\u2010based Practice","author":"Elliott D","year":"2007"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1345\/aph.1K041"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/1472-6963-5-50"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1362-1017.2003.00039.x"},{"key":"e_1_2_9_19_1","doi-asserted-by":"crossref","first-page":"325","DOI":"10.4037\/ajcc2005.14.4.325","article-title":"Effect of backrest on the development of ventilator associated pneumonia.","volume":"14","author":"Grap MJ","year":"2005","journal-title":"American Journal of Critical Care"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/j.2048-7940.2005.tb00101.x"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.4037\/ajcc2010917"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/MLR.0b013e3181893f6b"},{"key":"e_1_2_9_23_1","volume-title":"Measure Information Form: Ventilator Bundle Compliance, V06\u201011\/27\/2006\n            .","author":"Institute for Healthcare Improvement.","year":"2006"},{"key":"e_1_2_9_24_1","unstructured":"Institute for Healthcare Improvement.(2011).Implement the IHI ventilator bundle.http:\/\/www.ihi.org\/knowledge\/pages\/changes\/implementtheventilatorbundle.aspx(accessed 27\/02\/12)."},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1037\/0033-2909.119.2.254"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1086\/591455"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1478-5153.2010.00430.x"},{"key":"e_1_2_9_28_1","first-page":"61","article-title":"Semi\u2010 recumbent position in ICU.","volume":"11","author":"Li TST","year":"2008","journal-title":"Critical Care and Shock"},{"key":"e_1_2_9_29_1","volume-title":"Evidence\u2010based Practice in Nursing and Healthcare: A Guide to Best Practice\n            .","author":"Melnyk BM","year":"2005"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrc.2007.11.014"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1186\/1754-9493-2-3"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.NCQ.0000277782.29557.64"},{"key":"e_1_2_9_33_1","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.1016\/j.ijnurstu.2010.04.002","article-title":"The use of bed\u2010dials to maintain recumbent positioning for critically ill mechanically ventilated patients (The RECUMBENT study): multicentre before and after observational study.","volume":"47","author":"Rose L","journal-title":"International Journal of Nursing Studies"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrc.2007.11.013"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.7748\/paed2007.05.19.4.39.c7792"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000198529.76602.5E"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1478-5153.2008.00279.x"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1553-7250(07)33026-2"}],"container-title":["Nursing in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1478-5153.2012.00519.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1478-5153.2012.00519.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T16:29:27Z","timestamp":1698683367000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1478-5153.2012.00519.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,25]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["10.1111\/j.1478-5153.2012.00519.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1478-5153.2012.00519.x","archive":["Portico"],"relation":{},"ISSN":["1362-1017","1478-5153"],"issn-type":[{"value":"1362-1017","type":"print"},{"value":"1478-5153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6,25]]}}}