{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T11:01:56Z","timestamp":1707130916293},"reference-count":24,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2006,9,12]],"date-time":"2006-09-12T00:00:00Z","timestamp":1158019200000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2006,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>A 27\u2010year\u2010old Hispanic man with a history of hypertension and end\u2010stage renal disease for 4 years became unresponsive, apneic, and pulseless during hemodialysis. During his 4 year period on dialysis, vascular access had become increasingly difficult and ultimately a transhepatic catheter had been placed 9 months prior to this event. Resuscitation was unsuccessful. At autopsy, death was determined to be due to cardiac tamponade secondary to perforation of the right atrium by the transhepatic catheter. Cardiac tamponade is a rare cause of sudden death during hemodialysis with a long\u2010standing catheter.<\/jats:p>","DOI":"10.1111\/j.1525-139x.2006.00200.x","type":"journal-article","created":{"date-parts":[[2006,9,12]],"date-time":"2006-09-12T15:35:39Z","timestamp":1158075339000},"page":"434-437","source":"Crossref","is-referenced-by-count":3,"title":["A Dialysis Case Presentation and Discussion: A Case of Fatal Cardiac Tamponade During Hemodialysis"],"prefix":"10.1111","volume":"19","author":[{"suffix":"III","given":"Lorenz M.","family":"Schmiege","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dwayne A.","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,9,12]]},"reference":[{"key":"e_1_2_4_2_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1755.2001.00806.x"},{"key":"e_1_2_4_3_2","first-page":"148","volume-title":"Handbook of Dialysis","author":"Daugirdas JT","year":"2001"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/snep.2001.18378"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1159\/000182248"},{"key":"e_1_2_4_6_2","first-page":"337","article-title":"Cardiac tamponade due to central venous catheterization","volume":"37","author":"Nasim A","year":"1992","journal-title":"J R Coll Surg Edinb"},{"key":"e_1_2_4_7_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1982.01380310071017"},{"key":"e_1_2_4_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3468(92)90305-Q"},{"key":"e_1_2_4_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(98)70498-1"},{"key":"e_1_2_4_10_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2321030677"},{"key":"e_1_2_4_11_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.167.5.8911206"},{"key":"e_1_2_4_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000085770.63355.F2"},{"key":"e_1_2_4_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002470050531"},{"key":"e_1_2_4_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0272-6386(95)90585-5"},{"key":"e_1_2_4_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(97)70614-6"},{"key":"e_1_2_4_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005176-200205000-00017"},{"key":"e_1_2_4_17_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.153.6.1317-b"},{"key":"e_1_2_4_18_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/12.8.1689"},{"key":"e_1_2_4_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(99)00124-5"},{"key":"e_1_2_4_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7210541"},{"key":"e_1_2_4_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(00)00483-9"},{"key":"e_1_2_4_22_2","first-page":"15","article-title":"Precautions necessary with central venous catheters","author":"U.S. Food and Drug Administration Task Force","year":"1989","journal-title":"FDA Drug Bull"},{"issue":"1","key":"e_1_2_4_23_2","first-page":"S137","article-title":"K\/DOQI Clinical Practice Guidelines for Vascular Access","volume":"37","author":"National Kidney Foundation","year":"2001","journal-title":"Am J Kidney Dis"},{"key":"e_1_2_4_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000071097.76348.72"},{"key":"e_1_2_4_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X9402200303"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-139X.2006.00200.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-139X.2006.00200.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T05:23:37Z","timestamp":1697088217000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-139X.2006.00200.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,9]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2006,9]]}},"alternative-id":["10.1111\/j.1525-139X.2006.00200.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-139x.2006.00200.x","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,9]]}}}