{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:15:19Z","timestamp":1760955319198},"reference-count":21,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2011,12,9]],"date-time":"2011-12-09T00:00:00Z","timestamp":1323388800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2012,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Hemodialysis catheterization through the right internal jugular vein (IJV) is widely used for mid\u2010 to long\u2010term hemodialysis for patients with renal failure. The purpose of this report is to address a serious complication in conjunction with this procedure. This is a case report of an iatrogenic jugular\u2010carotid fistula (JCF) and a method for rectifying such a vascular conundrum, using endovascular techniques. We describe the technique used to achieve closure of the fistula as well a review of the literature. An 82\u2010year\u2010old woman with history of congestive heart failure, chronic renal failure, and diabetes mellitus developed an iatrogenic arteriovenous fistula, following an attempt of canalizing the right IJV. The patient was treated using three different stents, which achieved closure of the fistula. Venous catheter misplacement into an artery is a serious complication. Early endovascular treatment should be considered for a JCF.<\/jats:p>","DOI":"10.1111\/j.1525-139x.2011.01005.x","type":"journal-article","created":{"date-parts":[[2011,12,9]],"date-time":"2011-12-09T10:21:38Z","timestamp":1323426098000},"page":"460-463","source":"Crossref","is-referenced-by-count":18,"title":["Angioplasty and Stenting of a Jugular\u2010Carotid Fistula Resulting from the Inadvertent Placement of a Hemodialysis Catheter: Case Report and Review of Literature"],"prefix":"10.1111","volume":"25","author":[{"given":"Rishi","family":"Wadhwa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jamie","family":"Toms","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anil","family":"Nanda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth","family":"Abreo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hugo","family":"Cuellar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,12,9]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfi168"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1159\/000046203"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0404.2002.1c222.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2003.06.003"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2009.08.009"},{"key":"e_1_2_6_7_2","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1093\/milmed\/141.3.171","article-title":"Arteriovenous fistula as a complication of percutaneous internal jugular vein catheterization: case report","volume":"141","author":"Ortiz J","year":"1976","journal-title":"Mil Med"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1186\/1476-0711-2-3"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2008.04.046"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199412293312602"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-004-0039-z"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e31817fd954"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2004.12.046"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0888-6296(88)90230-X"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1159\/000168859"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1053\/jcan.2001.21980"},{"key":"e_1_2_6_17_2","first-page":"568","article-title":"Treatment with the placement of carotid stent of jugular\u2010carotid fistula after the insertion of hemodialysis catheter","volume":"25","author":"Vera M","year":"2005","journal-title":"Nefrologia"},{"key":"e_1_2_6_18_2","first-page":"101","article-title":"The use of endovascular stent\u2010grafts for the treatment of common carotid\u2010internal jugular fistula","volume":"27","author":"Bawazeer MA","year":"2006","journal-title":"Saudi Med J"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/112972980600700309"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.20222"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1542-4758.2010.00525.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1542-4758.2011.00556.x"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-139X.2011.01005.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-139X.2011.01005.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T01:40:58Z","timestamp":1698630058000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-139X.2011.01005.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12,9]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,7]]}},"alternative-id":["10.1111\/j.1525-139X.2011.01005.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-139x.2011.01005.x","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12,9]]}}}