{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T23:36:15Z","timestamp":1787960175018,"version":"build-2784847793"},"reference-count":41,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2012,2,22]],"date-time":"2012-02-22T00:00:00Z","timestamp":1329868800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2012,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Abnormal renal function is an independent risk factor for cardiac implantable electronic device (CIED) infection. The risk of CIED infection increases as the degree of renal dysfunction worsens with the highest risk observed in patients with stage V chronic kidney disease. A significant portion of these patients use a tunneled hemodialysis catheter (TDC) for dialysis therapy. These devices are associated with very high rates of catheter\u2010related bacteremia (1.6\u20135.5 episodes of bacteremia per 1000 catheter days), and have been known to cause infection of CIED indwelling in the bloodstream. In this context, the cardiac device is exposed to the risk of infection due to the presence of renal failure and episodes of bacteremia related to TDCs. Both increase the risk of CIED infection. Once infected, a cardiac rhythm device carries a marked increase in morbidity and mortality. In this context, the combination of a TDC and a CIED indwelling in the bloodstream becomes a potentially deadly combination. Recent data have emphasized that epicardial CIED implantation reduces cardiac device infection in TDC patients. This report highlights the risk of CIED infection in renal patients, presents TDC\u2019s contribution to the cardiac device infection, and suggests recommendations to minimize the risk of CIED infection in chronic hemodialysis patients dialyzing with a TDC.<\/jats:p>","DOI":"10.1111\/j.1525-139x.2012.01053.x","type":"journal-article","created":{"date-parts":[[2012,2,22]],"date-time":"2012-02-22T12:43:48Z","timestamp":1329914628000},"page":"582-586","source":"Crossref","is-referenced-by-count":29,"title":["Transvenous Cardiac Implantable Electronic Devices and Hemodialysis Catheters: Recommendations to Curtail a Potentially Lethal Combination"],"prefix":"10.1111","volume":"25","author":[{"given":"Arif","family":"Asif","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Loay","family":"Salman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gustavo","family":"Lopera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Syed S.","family":"Haqqie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger","family":"Carrillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,2,22]]},"reference":[{"key":"e_1_2_4_2_2","first-page":"S257","article-title":"Atlas of chronic kidney disease and end\u2010stage renal disease in the United States","volume":"53","author":"US Renal Data System, Excerpts from the United States Renal Data System 2008 Annual Data Report","year":"2009","journal-title":"Am J Kidney Dis"},{"key":"e_1_2_4_3_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2011.05.005"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2011.03.026"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(85)90020-1"},{"key":"e_1_2_4_6_2","first-page":"112","article-title":"Permanent cardiac pacing for chronic symptomatic atrioventricular block in uremic hemodialysed patients. A prospective study","volume":"106","author":"Arsenescu C","year":"2002","journal-title":"Rev Med Chir Soc Med Nat Iasi"},{"key":"e_1_2_4_7_2","unstructured":"KarchmerAW:Infection of cardiac pacemaker and implantable cardioverter defibrillator. UpToDate. Accessed December 2011."},{"key":"e_1_2_4_8_2","doi-asserted-by":"publisher","DOI":"10.1159\/000187285"},{"key":"e_1_2_4_9_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2008.151985"},{"key":"e_1_2_4_10_2","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1540-8159.2006.00307.x","article-title":"Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery","volume":"29","author":"Bloom H","year":"2006","journal-title":"PACE"},{"key":"e_1_2_4_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2011.02066.x"},{"key":"e_1_2_4_12_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2006.04.029"},{"key":"e_1_2_4_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1542-4758.2009.00396.x"},{"key":"e_1_2_4_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2008.00497.x"},{"key":"e_1_2_4_15_2","doi-asserted-by":"publisher","DOI":"10.1086\/502103"},{"key":"e_1_2_4_16_2","first-page":"172","article-title":"Experience with tunneled femoral hemodialysis catheters","volume":"58","author":"Zaleski GX","year":"1999","journal-title":"Am J Roentgenol"},{"key":"e_1_2_4_17_2","first-page":"46","article-title":"Vascular access related infections in hemodialysis patients","volume":"16","author":"Saxena AK","year":"2005","journal-title":"Saudi J Kidney Dis Transplant"},{"key":"e_1_2_4_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005792-196801000-00001"},{"key":"e_1_2_4_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1523-1755.2000.00337.x"},{"key":"e_1_2_4_20_2","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1681\/ASN.V95869","article-title":"EPIBACDIAL: a multicenter prospective study of risk factors for bacteremia in chronic hemodialysis patients","volume":"9","author":"Hoen B","year":"1998","journal-title":"J Am Soc Nephrol"},{"key":"e_1_2_4_21_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2010.01.009"},{"key":"e_1_2_4_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2010.00757.x"},{"key":"e_1_2_4_23_2","first-page":"566A","article-title":"Cardiac rhythm devices and arteriovenous access dysfunction in hemodialyzed patients: experience in a single urban vascular access center","volume":"22","author":"Brinda Desiraju B","year":"2011","journal-title":"J Am Soc Nephrol"},{"key":"e_1_2_4_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(00)70338-6"},{"key":"e_1_2_4_25_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1755.1999.0550031081.x"},{"key":"e_1_2_4_26_2","doi-asserted-by":"publisher","DOI":"10.1159\/000210001"},{"key":"e_1_2_4_27_2","doi-asserted-by":"publisher","DOI":"10.5414\/CN106479"},{"key":"e_1_2_4_28_2","doi-asserted-by":"publisher","DOI":"10.1586\/17434440.5.2.183"},{"key":"e_1_2_4_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2008.01039.x"},{"key":"e_1_2_4_30_2","doi-asserted-by":"publisher","DOI":"10.2459\/JCM.0b013e32832b3585"},{"key":"e_1_2_4_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(94)90143-0"},{"key":"e_1_2_4_32_2","doi-asserted-by":"publisher","DOI":"10.1161\/hc3401.095097"},{"key":"e_1_2_4_33_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/17.12.2226"},{"key":"e_1_2_4_34_2","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/12.6.1301"},{"key":"e_1_2_4_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2000.tb00845.x"},{"key":"e_1_2_4_36_2","doi-asserted-by":"publisher","DOI":"10.1023\/B:JICE.0000042354.87946.39"},{"key":"e_1_2_4_37_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2006.00314.x"},{"key":"e_1_2_4_38_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.103.21.2585"},{"key":"e_1_2_4_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.01.014"},{"key":"e_1_2_4_40_2","unstructured":"http:\/\/www.fistualfirst.org. Epicardial leads. Accessed January 30 2012."},{"key":"e_1_2_4_41_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909545"},{"key":"e_1_2_4_42_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.46.2.409"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-139X.2012.01053.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-139X.2012.01053.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T16:58:48Z","timestamp":1698685128000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-139X.2012.01053.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2,22]]},"references-count":41,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["10.1111\/j.1525-139X.2012.01053.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-139x.2012.01053.x","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2,22]]}}}