{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T16:47:04Z","timestamp":1778258824241,"version":"3.51.4"},"reference-count":7,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":4322,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[1997,3]]},"abstract":"<jats:p>Open\u2010loop and closed\u2010loop stimulation of the knee extensors for the controlof the knee joint angle and torque were tested as a potential basis for morecomplex functional electrical stimulation (FES) systems to be used in human locomotion. The output of the biomechanical simulation model described previously was compared with stimulation experiments in patients with complete thoracic spinal cordinjury. Good correspondence between simulation and experiments was obtained under both isometric conditions and conditions with a freely swinging shank. For closed\u2010loop control, a simple proportional integral derivative (PID) controller yieldedsufficient performance only under isometric conditions, especially if combined with (linear) feedforward. Because ofadditional nonlinearities of musculotendon and body segmental dynamics, morecomplex strategies have to be applied to the control of unconstrained movements. To compensate for these nonlinearities, an inverse model was derived from the direct biomechanical model. This inverse model had satisfactory agreement between themeasured knee angle and the desired trajectory already under open\u2010loop conditions. A combination of the inverse model in the feedforward part of the control loop and a PID controller provided robust and precise control of the knee angle. Furtherimprovement may be achieved by including elements of spasticity into the simulation model and by controlling both agonistic and antagonistic muscles.<\/jats:p>","DOI":"10.1111\/j.1525-1594.1997.tb04656.x","type":"journal-article","created":{"date-parts":[[2008,12,31]],"date-time":"2008-12-31T22:45:21Z","timestamp":1230763521000},"page":"232-235","source":"Crossref","is-referenced-by-count":25,"title":["Comparison of Simulation and Experiments of Different Closed\u2010Loop Strategies for Functional Electrical Stimulation: Experiments in Paraplegics"],"prefix":"10.1111","volume":"21","author":[{"given":"J.","family":"Quintern","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Riener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Rupprecht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_5_2_2","unstructured":"RienerR QuinternJ VolzS.Comparison of simulation andexperiments of different closed\u2010loop strategies forFES.Part 1: Simulation model.Proceedings of the 5th Vienna International Workshop on FunctionalElectrostimulation. Vienna Austria 1995:251\u201354."},{"key":"e_1_2_5_3_2","first-page":"64","article-title":"Development of a practical electrical stimulation system for restoringgait in the paralyzed patient.","volume":"21","author":"Marsolais EB","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_5_4_2","unstructured":"ChizeckHJ.Adaptive and nonlinear control methods for neural prostheses.In: Stein RB Peckham H Popovic DP eds.Neural prostheses. Replacing motor function after disease ordisability. New York: Oxford 1992:298\u2013328."},{"key":"e_1_2_5_5_2","first-page":"81","volume":"21","author":"Veltink PH","year":"1990","journal-title":"Advances of external control of human extremities"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0079-6123(08)62248-7"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.1988.60.3.1110"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/104.3.431"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.1997.tb04656.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.1997.tb04656.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/j.1525-1594.1997.tb04656.x","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.1997.tb04656.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,11]],"date-time":"2023-09-11T06:54:20Z","timestamp":1694415260000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.1997.tb04656.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,3]]},"references-count":7,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1997,3]]}},"alternative-id":["10.1111\/j.1525-1594.1997.tb04656.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.1997.tb04656.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,3]]}}}