{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T17:13:48Z","timestamp":1790615628638,"version":"4.1.0"},"reference-count":25,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2005,6,24]],"date-time":"2005-06-24T00:00:00Z","timestamp":1119571200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2005,7]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold> Thousands of adult cardiac failure patients may benefit from the availability of an effective, long\u2010term ventricular assist device (VAD). We have developed a fully implantable, axial flow VAD (LEV\u2010VAD) with a magnetically levitated impeller as a viable option for these patients. This pump's streamlined and unobstructed blood flow path provides its unique design and facilitates continuous washing of all surfaces contacting blood. One internal fluid contacting region, the diffuser, is extremely important to the pump's ability to produce adequate pressure but is challenging to manufacture, depending on the complex blade geometries. This study examines the influence of the diffuser on the overall LEV\u2010VAD performance. A combination of theoretical analyses, computational fluid (CFD) simulations, and experimental testing was performed for three different diffuser models: six\u2010bladed, three\u2010bladed, and no\u2010blade configuration. The diffuser configurations were computationally and experimentally investigated for flow rates of 2\u201310\u2003L\/min at rotational speeds of 5000\u20138000\u2003rpm. For these operating conditions, CFD simulations predicted the LEV\u2010VAD to deliver physiologic pressures with hydraulic efficiencies of 15\u201332%. These numerical performance results generally agreed within 10% of the experimental measurements over the entire range of rotational speeds tested. Maximum scalar stress levels were estimated to be 450\u2003Pa for 6\u2003L\/min at 8000\u2003rpm along the blade tip surface of the impeller. Streakline analysis demonstrated maximum fluid residence times of 200\u2003ms with a majority of particles exiting the pump in 80\u2003ms. Axial fluid forces remained well within counter force generation capabilities of the magnetic suspension design. The no\u2010bladed configuration generated an unacceptable hydraulic performance. The six\u2010diffuser\u2010blade model produced a flow rate of 6\u2003L\/min against 100\u2003mm\u2003Hg for 6000\u2003rpm rotational speed, while the three\u2010diffuser\u2010blade model produced the same flow rate and pressure rise for a rotational speed of 6500\u2003rpm. The three\u2010bladed diffuser configuration was selected over the six\u2010bladed, requiring only an incremental adjustment in revolution per minute to compensate for and ease manufacturing constraints. The acceptable results of the computational simulations and experimental testing encourage final prototype manufacturing for acute and chronic animal studies.\u2003<\/jats:p>","DOI":"10.1111\/j.1525-1594.2005.29095.x","type":"journal-article","created":{"date-parts":[[2005,6,24]],"date-time":"2005-06-24T15:45:36Z","timestamp":1119627936000},"page":"581-591","source":"Crossref","is-referenced-by-count":40,"title":["Numerical and Experimental Analysis of an Axial Flow Left Ventricular Assist Device: The Influence of the Diffuser on Overall Pump Performance"],"prefix":"10.1111","volume":"29","author":[{"given":"Alexandrina","family":"Untaroiu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amy L.","family":"Throckmorton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonna M.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Houston G.","family":"Wood","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul E.","family":"Allaire","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Don B.","family":"Olsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,6,24]]},"reference":[{"key":"e_1_2_6_2_2","volume-title":"Heart and Stroke Statistical Update.","author":"American Heart Association."},{"key":"e_1_2_6_3_2","unstructured":"National Heart Lung and Blood Institute.Facts About Heart Failure. Available at:http:\/\/www.nhlbi.nih.gov. Accessed September 2004."},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.97.20.2079"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2000.06652.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1997.tb00464.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199207000-00041"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2000.06635.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02614-X"},{"key":"e_1_2_6_10_2","first-page":"355","article-title":"Axial flow blood pumps","volume":"49","author":"Song X","year":"2003","journal-title":"ASAIO J"},{"key":"e_1_2_6_11_2","volume-title":"Centrifugal and Axial Flow Pump","author":"Stepanoff AJ.","year":"1957"},{"key":"e_1_2_6_12_2","volume-title":"Theory of Turbomachines","author":"Csanady GT.","year":"1964"},{"key":"e_1_2_6_13_2","volume-title":"Hydrodynamics of Pumps","author":"Brennen CE.","year":"1994"},{"key":"e_1_2_6_14_2","volume-title":"Turbomachines\u2014A Guide to Selection and Theory","author":"Balje OE.","year":"1981"},{"key":"e_1_2_6_15_2","unstructured":"HuangCR FabisiakW.A rheological equation characterizing both the time dependent and the steady state viscosity of whole human blood.AICHE Symposium Series 1978;19\u201321."},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.133.3455.763"},{"key":"e_1_2_6_17_2","volume-title":"Physiology","author":"Berne RM","year":"1998"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2000.06580.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200209000-00019"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.1999.06418.x"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.1998.06149.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"crossref","unstructured":"DaySW WolovickA WoodHG AllairePE KippR.Experimental measurements of pump performance in support of pump design.ASAIO\u2010ISAO Joint Conference. Washington DC 2003.","DOI":"10.1097\/00002480-200303000-00317"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200109000-00031"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1995.tb02386.x"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.1758259"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2003.07103.x"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2005.29095.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2005.29095.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T12:34:02Z","timestamp":1697373242000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2005.29095.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6,24]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2005,7]]}},"alternative-id":["10.1111\/j.1525-1594.2005.29095.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2005.29095.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6,24]]}}}