{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T12:59:43Z","timestamp":1761742783077},"reference-count":41,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2006,5,26]],"date-time":"2006-05-26T00:00:00Z","timestamp":1148601600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2006,6]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold> Continuous cardiac output (CO) and mixed venous oxygen saturation (SvO<jats:sub>2<\/jats:sub>) determined through the pulmonary artery catheter may be helpful in monitoring hemodynamic conditions in critically ill patients. This study aimed to evaluate CO and SvO<jats:sub>2<\/jats:sub> in a model of acute normovolemic hemodilution (ANH), analyzing the accuracy of the continuous versus intermittent method for CO and SvO<jats:sub>2<\/jats:sub> measurement in pigs. Twenty\u2010three pigs were enrolled to three groups: control, ANH with 6% hydroxyethyl starch (HES), or ANH with lactated Ringer\u2019s (LR) solution. After hemodilution, we showed that SvO<jats:sub>2<\/jats:sub> was reduced in both groups, mainly in LR animals (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.05). Regarding the evaluation of CO, we showed an increase in both groups submitted to ANH (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.05). Through Bland\u2013Altman analysis, we showed that the continuous CO catheter presented lower values than the intermittent method after hemodilution, mainly with HES (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.001), and there was no difference in the measurement of SvO<jats:sub>2<\/jats:sub>. The ANH promoted a decrease in SvO<jats:sub>2<\/jats:sub> and an increase in CO values, mainly in animals submitted to hemodilution with HES. The use of continuous and intermittent (laboratory) measurement of SvO<jats:sub>2<\/jats:sub> showed clinical applicability and good agreement, an effect not reproduced by the CO measurement. New studies are needed to further investigate the agreement between the continuous and intermittent methods for the measurement of CO in adverse hemodynamic conditions such as ANH.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2006.00242.x","type":"journal-article","created":{"date-parts":[[2006,5,26]],"date-time":"2006-05-26T09:48:54Z","timestamp":1148636934000},"page":"458-466","source":"Crossref","is-referenced-by-count":3,"title":["Comparison Between Intermittent and Continuous Measurement of Cardiac Output After Acute Normovolemic Hemodilution in Pigs"],"prefix":"10.1111","volume":"30","author":[{"given":"Denise A.","family":"Otsuki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernando A.","family":"Cardieri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9 P.","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcio","family":"Brudniewski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denise T.","family":"Fantoni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr","given":"Jos\u00e9 O.C.","family":"Auler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,5,26]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200310000-00036"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcnurse.2004.02.003"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/81.6.945"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-9441(98)90006-5"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199505000-00014"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02077635"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2000.40091054.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1992.32392213805.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1994.34394196628.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198803000-00017"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199907000-00008"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200301000-00007"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1186\/cc1453"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2003.03.003"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1994.tb03935.x"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198303000-00016"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197008272830902"},{"key":"e_1_2_6_19_2","first-page":"1001","article-title":"Reliability of the thermodilution method in the determination of cardiac output in clinical practice","volume":"126","author":"Stetz CW","year":"1982","journal-title":"Am Rev Respir Dis"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-0770(05)80095-3"},{"key":"e_1_2_6_21_2","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1007\/BF01700452","article-title":"Semi\u2010continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery","volume":"22","author":"Bottiger BW","year":"1996","journal-title":"Intensive Care Med"},{"key":"e_1_2_6_22_2","first-page":"52","article-title":"Continuous invasive cardiac output monitoring\u2014the Baxter\/Edwards Critical\u2010Care Swan Ganz IntelliCath inverted question mark and Viligance inverted question mark system","volume":"5","author":"Munro HM","year":"1994","journal-title":"Clin Intensive Care"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/1053-0770(92)90137-V"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199422120-00005"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001340050811"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198112000-00010"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199505000-00025"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/1053-0770(94)90200-3"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199908000-00011"},{"key":"e_1_2_6_30_2","first-page":"A398","article-title":"Accuracy, of continuous cardiac output determination with the heat filament catheter varies with infusion rates","volume":"85","author":"Greim C","year":"1996","journal-title":"Anesthesiology"},{"key":"e_1_2_6_31_2","first-page":"A473","article-title":"Continuous cardiac output may be more accurate than bolus thermodilution output during the use of an upper\u2010body warming\u2010blanket","volume":"79","author":"Spackman ER","year":"1993","journal-title":"Anesthesiology"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.152.6.8520741"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1997.079-az0077.x"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/76.1.81"},{"key":"e_1_2_6_35_2","first-page":"355","article-title":"Haemodilution in clinical anesthesia","volume":"67","author":"Auler JO","year":"2001","journal-title":"Minerva Anestesiol"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200005000-00012"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1988.tb02843.x"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.279.3.217"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200010000-00024"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-198206000-00007"},{"key":"e_1_2_6_41_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.98.4.954"},{"key":"e_1_2_6_42_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4615-3428-0_60"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2006.00242.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2006.00242.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T10:05:45Z","timestamp":1697105145000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2006.00242.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,5,26]]},"references-count":41,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2006,6]]}},"alternative-id":["10.1111\/j.1525-1594.2006.00242.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2006.00242.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,5,26]]}}}