{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T11:31:33Z","timestamp":1791199893724,"version":"4.2.0"},"reference-count":23,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2008,3,27]],"date-time":"2008-03-27T00:00:00Z","timestamp":1206576000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2008,4]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold> Powered orthosis is a special class of gait assist device that employs a mechanical or electromechanical actuator to enhance movement of hip, knee, or ankle articulations. Pneumatic artificial muscle (PAM) has been suggested as a pneumatic actuator because its performance is similar to biological muscle. The electromyography (EMG) signal interpretation is the most popular and simplest method to establish the patient voluntary control of the orthosis. However, this technique is not suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. For those cases, an alternative control strategy should be provided. The aim of the present study is to develop a gait assistance orthosis for lower limb powered by PAMs controlled by a voluntary activation method based on the angular behavior of hip joint. In the present study, an orthosis that has been molded in a patient was employed and, by taking her anthropometric parameters and movement constraints, the adaptation of the existing orthosis to the powered orthosis was planned. A control system was devised allowing voluntary control of a powered orthosis suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. A pilot clinical study was reported where a patient, victim of poliovirus, successfully tested a hip orthosis especially modified for the gait test evaluation in the parallel bar system. The hip orthosis design and the control circuitry parameters were able to be set to provide satisfactory and comfortable use of the orthosis during the gait cycle.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2008.00549.x","type":"journal-article","created":{"date-parts":[[2008,3,27]],"date-time":"2008-03-27T07:43:42Z","timestamp":1206603822000},"page":"317-322","source":"Crossref","is-referenced-by-count":39,"title":["Hip Orthosis Powered by Pneumatic Artificial Muscle: Voluntary Activation in Absence of Myoelectrical Signal"],"prefix":"10.1111","volume":"32","author":[{"given":"Breno Gontijo","family":"Do Nascimento","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claysson Bruno Santos","family":"Vimieiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danilo Alves Pinto","family":"Nagem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcos","family":"Pinotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,3,27]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2005.05.004"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.05.018"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.sc.3100462"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-9993(95)80534-6"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(06)85221-8"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/86.769402"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2003.823266"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/70.481753"},{"key":"e_1_2_6_10_2","first-page":"1776","article-title":"Fatigue characteristics of McKibben artificial muscle actuators","volume":"3","author":"Klute GK","year":"1998","journal-title":"IEEE\/RSJ International Conference on Intelligent Robots and Systems"},{"key":"e_1_2_6_11_2","first-page":"221","article-title":"McKibben artificial muscles: pneumatic actuators with biomechanical intelligence","volume":"1","author":"Klute GK","year":"1999","journal-title":"IEEE\/ASME International Conference on Advanced Intelligent Mechatronics"},{"key":"e_1_2_6_12_2","first-page":"289","volume-title":"Actuator 2000: 7th International Conference on New Actuators","author":"Klute GK","year":"2000"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1123\/jab.21.2.189"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00010-1"},{"key":"e_1_2_6_15_2","first-page":"283","article-title":"Myoelectric control of prostheses","volume":"13","author":"Parker PA","year":"1986","journal-title":"Crit Rev Biomed Eng"},{"key":"e_1_2_6_16_2","first-page":"205","article-title":"Developing intelligent control from a biological perspective to examine paradigms for activation utilizing pneumatic muscle actuators","volume":"1","author":"Repperger DW","year":"2000","journal-title":"IEEE International Symposium on Intelligent Control"},{"key":"e_1_2_6_17_2","first-page":"271","volume-title":"Atlas of Limb Prosthetics: Surgical and Prosthetic Principles","author":"Bowker JH","year":"1981"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(03)00005-5"},{"key":"e_1_2_6_19_2","first-page":"4","volume-title":"Proceedings of the 18th International Conference on Mechanical Engineering\u2014COBEM","author":"Nagem DAP","year":"2005"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00264-1"},{"key":"e_1_2_6_21_2","first-page":"301","article-title":"Research and clinical aspects of the late effects of poliomyelitis","volume":"23","author":"Halstead LS","year":"1987","journal-title":"Birth Defects"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1093\/aje\/136.7.769"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(02)00104-2"},{"key":"e_1_2_6_24_2","first-page":"367","article-title":"Symptoms and clinical impressions of patients seen in a postpolio clinic","volume":"70","author":"Agre JC","year":"1989","journal-title":"Arch Phys Med Rehabil"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2008.00549.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2008.00549.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T18:12:42Z","timestamp":1697393562000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2008.00549.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3,27]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["10.1111\/j.1525-1594.2008.00549.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2008.00549.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,3,27]]}}}