{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T15:19:43Z","timestamp":1774624783717,"version":"3.50.1"},"reference-count":26,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2010,9,26]],"date-time":"2010-09-26T00:00:00Z","timestamp":1285459200000},"content-version":"vor","delay-in-days":25,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2010,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A pulsatility\u2010based control algorithm with a self\u2010adapting pulsatility reference value is proposed for an implantable rotary blood pump and is to be tested in computer simulations. The only input signal is the pressure difference across the pump, which is deduced from measurements of the pump's magnetic bearing. A pulsatility index (PI) is calculated as the mean absolute deviation from the mean pressure difference. As a second characteristic, the gradient of the PI with respect to the pump speed is derived. This pulsatility gradient (GPI) is used as the controlled variable to adjust the operating point of the pump when physiological variables such as the systemic arterial pressure, left ventricular contractility, or heart rate change. Depending on the selected mode of operation, the controller is either a linear controller or an extremum\u2010seeking controller. A supervisory mechanism monitors the state of the system and projects the system into the region of convergence when necessary. The controller of the GPI continuously adjusts the reference value for PI. An underlying robust linear controller regulates the PI to the reference value in order to take into account changes in pulmonary venous return. As a means of reacting to sudden changes in the venous return, a suction detection mechanism was included. The control system is robustly stable within a wide range of physiological variables. All the clinician needs to do is to select between the two operating modes. No other adjustments are required. The algorithm showed promising results which encourage further testing in vitro and in vivo.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2010.01092.x","type":"journal-article","created":{"date-parts":[[2010,9,27]],"date-time":"2010-09-27T04:00:37Z","timestamp":1285560037000},"page":"726-735","source":"Crossref","is-referenced-by-count":30,"title":["Fully Autonomous Preload\u2010Sensitive Control of Implantable Rotary Blood Pumps"],"prefix":"10.1111","volume":"34","author":[{"given":"Andreas","family":"Arndt","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"N\u00fcsser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Lampe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,9,26]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa067758"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.03.055"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2009.08.014"},{"key":"e_1_2_6_5_2","unstructured":"Thoratec Corporation.Heartmate II LVAS Operating Manual 2008. Available at:http:\/\/www.thoratec.com. Accessed September 30 2008."},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2004.00011.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2006.00282.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2006.00283.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e318147e6a9"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2007.00409.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e3181aa2554"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2006.890288"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2005.02.004"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2005.09.008"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2007.00350.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2008.00628.x"},{"key":"e_1_2_6_17_2","doi-asserted-by":"crossref","unstructured":"ArndtA NuesserP LampeB MuellerJ.Physiological control of a rotary left ventricular assist device: robust control of pressure pulsatility with suction prevention and suppression. InWorld Congress on Medical Physics and Biomedical Engineering Munich Germany Volume 25\/7. IFMBE Proceedings September 7\u201312 2009. Berlin: Springer 2009;775\u20138.","DOI":"10.1007\/978-3-642-03885-3_215"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2009.00932.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"crossref","unstructured":"AntakiJF BostonJR SimaanMA.Control of heart assist devices. InProceedings of the 42nd Conference on Decision and Control Volume 4. IEEE December 9\u201312 2003 2003;4084\u20139.","DOI":"10.1109\/CDC.2003.1271791"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.919723"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2001.06859.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/0471669784"},{"key":"e_1_2_6_23_2","unstructured":"ArndtA.Physiological control of implantable rotary blood pumps for chronic left ventricular assistance. PhD thesis University of Rostock 2009."},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.2005960"},{"key":"e_1_2_6_25_2","first-page":"574","article-title":"Suction control for the Incor axial flow blood pump\u2014clinical results (abstract)","volume":"27","author":"Arndt A","year":"2004","journal-title":"Int J Artif Organs"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/87.918900"},{"key":"e_1_2_6_27_2","doi-asserted-by":"crossref","unstructured":"FerreiraA ChenS SimaanMA BostonJR AntakiJF.A discriminant\u2010analysis\u2010based suction detection system for rotary blood pumps. InProceedings of the 28th EMBS New York. IEEE Aug 30\u2013Sep 3 2006 2006;5382\u20135.","DOI":"10.1109\/IEMBS.2006.260621"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2010.01092.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2010.01092.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T02:27:39Z","timestamp":1740536859000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2010.01092.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["10.1111\/j.1525-1594.2010.01092.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2010.01092.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,9]]}}}