{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T06:30:59Z","timestamp":1771914659130,"version":"3.50.1"},"reference-count":17,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2011,3,15]],"date-time":"2011-03-15T00:00:00Z","timestamp":1300147200000},"content-version":"vor","delay-in-days":14,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2011,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A stimulator for neuromuscular electrical stimulation (NMES) was designed, especially suiting the requirements of elderly people with reduced cognitive abilities and diminished fine motor skills. The aging of skeletal muscle is characterized by a progressive decline in muscle mass, force, and condition. Muscle training with NMES reduces the degradation process. The discussed system is intended for evoked muscle training of the anterior and posterior thigh. The core of the stimulator is based on a microcontroller with two modular output stages. The system has two charge\u2010balanced biphasic voltage\u2010controlled stimulation channels. Additionally, the evoked myoelectric signal (M\u2010wave) and the myokinematic signal (surface acceleration) are measured. A central controller unit allows using the stimulator as a stand\u2010alone device. To set up the training sequences and to evaluate the compliance data, a personal computer is connected to the stimulator via a universal serial bus. To help elderly people handle the stimulator by themselves, the user interface is kept very simple. For safety reasons, the electrode impedance is monitored during stimulation. A comprehensive compliance management with included measurements of muscle activity and stimulation intensity enables a scientific use of the stimulator in clinical trials.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2011.01217.x","type":"journal-article","created":{"date-parts":[[2011,3,15]],"date-time":"2011-03-15T07:29:01Z","timestamp":1300174141000},"page":"253-256","source":"Crossref","is-referenced-by-count":16,"title":["Safe Neuromuscular Electrical Stimulator Designed for the Elderly"],"prefix":"10.1111","volume":"35","author":[{"given":"Matthias","family":"Krenn","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Haller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manfred","family":"Bijak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ewald","family":"Unger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Hofer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Kern","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Winfried","family":"Mayr","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,3,15]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00347.2003"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00246.2003"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-510X(88)90132-3"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1179\/016164110X12556180206310"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199907)22:7<831::AID-MUS4>3.0.CO;2-3"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-003-0991-3"},{"key":"e_1_2_6_8_2","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1093\/ptj\/74.1.71","article-title":"Effects of age and training on skeletal muscle physiology and performance","volume":"74","author":"Thompson LV","year":"1994","journal-title":"Phys Ther"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.2165\/00007256-200535030-00002"},{"key":"e_1_2_6_10_2","first-page":"640","article-title":"Short\u2010term effects of electrical stimulation superimposed on muscular voluntary contraction in postural control in elderly women","volume":"19","author":"Paillard T","year":"2005","journal-title":"J Strength Cond Res"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2002.06935.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2004.08.016"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2004.01.0041"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.1999.06370.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1163\/156855701321138969"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2009.06.006"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/ISCAS.2007.378401"},{"key":"e_1_2_6_18_2","first-page":"293","article-title":"Electrically evoked myoelectric signals","volume":"19","author":"Merletti R","year":"1992","journal-title":"Crit Rev Biomed Eng"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2011.01217.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2011.01217.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T00:52:36Z","timestamp":1697417556000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2011.01217.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,3]]}},"alternative-id":["10.1111\/j.1525-1594.2011.01217.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2011.01217.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,3]]}}}