{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T08:13:25Z","timestamp":1697444005515},"reference-count":31,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2011,8,15]],"date-time":"2011-08-15T00:00:00Z","timestamp":1313366400000},"content-version":"vor","delay-in-days":14,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2011,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Limited preload sensitivity of rotary left ventricular assist devices (LVADs) renders patients susceptible to harmful atrial or ventricular suction events. Active control systems may be used to rectify this problem; however, they usually depend on unreliable sensors or potentially inaccurate inferred data from, for example, motor current. This study aimed to characterize the performance of a collapsible inflow cannula reservoir as a passive control system to eliminate suction events in extracorporeal, rotary LVAD support. The reservoir was evaluated in a mock circulation loop against a rigid cannula under conditions of reduced preload and increased LVAD speed in both atrial and ventricular cannulation scenarios. Both cases demonstrated the ease with which chamber suction events can occur with a rigid cannula and confirm that the addition of the reservoir maintained positive chamber volumes with reduced preload and high LVAD speeds. Reservoir performance was dependent on height with respect to the cannulated chamber, with lower placement required in atrial cannulation due to reduced filling pressures. This study concluded that a collapsible inflow cannula is capable of minimizing suction events in extracorporeal, rotary LVAD support.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2011.01311.x","type":"journal-article","created":{"date-parts":[[2011,8,15]],"date-time":"2011-08-15T18:12:13Z","timestamp":1313431933000},"page":"765-772","source":"Crossref","is-referenced-by-count":10,"title":["In Vitro Evaluation of a Compliant Inflow Cannula Reservoir to Reduce Suction Events With Extracorporeal Rotary Ventricular Assist Device Support"],"prefix":"10.1111","volume":"35","author":[{"given":"Shaun David","family":"Gregory","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Timms","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas Richard","family":"Gaddum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"McDonald","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark John","family":"Pearcy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John F.","family":"Fraser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,8,15]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2010.01.011"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(71)90076-2"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa053063"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semtcvs.2008.08.001"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semtcvs.2008.08.002"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2008.01.027"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)01998-6"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(93)91174-L"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909938"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.07.086"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.09.001"},{"key":"e_1_2_7_13_2","doi-asserted-by":"crossref","first-page":"11","DOI":"10.15420\/usc.2010.7.2.11","article-title":"Use of echocardiography to optimize left ventricular assist devices","volume":"7","author":"Kirkpatrick JN","year":"2010","journal-title":"US Cardiology"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2010.01093.x"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e318142bfce"},{"key":"e_1_2_7_16_2","unstructured":"YuYC PorterJ.Mathematical modeling of ventricular suction induced by a rotary ventricular assist device.In Proceedings of the 2006 American Control Conference. Minneapolis Minnesota USA 2006."},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2007.00420.x"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2007.05.011"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12265-010-9216-4"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2010.01066.x"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e31815b2d1e"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e3181d2a56e"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2008.10.007"},{"key":"e_1_2_7_24_2","unstructured":"YiW.Physiological control of a rotary left ventricular assist device.In 26th Chinese Control Conference. Zhangjiajie Hunan China 2007."},{"issue":"2","key":"e_1_2_7_25_2","article-title":"Concepts of neonatal ECMO","volume":"1","author":"Thakar DR","year":"2001","journal-title":"The Internet Journal of Perfusionists"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139889401701204"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1057\/jos.2009.15"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2010.01088.x"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2010.02.012"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.03.055"},{"key":"e_1_2_7_31_2","first-page":"269","article-title":"Baroreceptor reflex in heart failure","volume":"56","author":"Wang W","year":"2004","journal-title":"Acta Physiol Sin"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.lfs.2006.01.045"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2011.01311.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2011.01311.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T21:51:42Z","timestamp":1697406702000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2011.01311.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2011,8]]}},"alternative-id":["10.1111\/j.1525-1594.2011.01311.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2011.01311.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,8]]}}}