{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:13:37Z","timestamp":1792613617024,"version":"4.5.0"},"reference-count":33,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2012,8,6]],"date-time":"2012-08-06T00:00:00Z","timestamp":1344211200000},"content-version":"vor","delay-in-days":5,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2012,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The Harboe spectrophotometric assay is regarded as one of the safest and most reproducible methods for measuring plasma free hemoglobin (pfHb). However, there is still some ambiguity in the application of the assay when assessing the hemolytic performance of ventricular assist devices (VADs). The purpose of this study was to reexamine and compare values of pfHb obtained using different concentrations of plasma diluent (Na<jats:sub>2<\/jats:sub>CO<jats:sub>3<\/jats:sub>) as cited by various studies such that a standard practice may be recommended for the application of the Harboe assay in the hemolytic evaluation of VADs, allowing reliable comparisons to be made between laboratories. As a means to examine the Harboe assay, a BioMedicus BPX\u201080 was tested using both whole blood and a washed suspension of red blood cells (RBCs). Results show that for whole blood, the pfHb may be underestimated by 13\u201323%, dependent upon the concentration of Na<jats:sub>2<\/jats:sub>CO<jats:sub>3<\/jats:sub> diluent solution. This trend was not observed for the washed suspension of RBCs. Furthermore, it is shown that the concentration of diluent influences the stability of a sample. The results of this study show that the problems associated with the incongruity of pfHb readings are a direct result of the precipitation of proteins from the plasma under alkaline conditions; as the molarity of the diluent controls pH, it becomes essential to use the appropriate concentration of Na<jats:sub>2<\/jats:sub>CO<jats:sub>3<\/jats:sub> diluent in order to avoid turbidity of the solution and the consequent misrepresentation of pfHb values. Such standardization is pertinent when measuring the very low levels of pfHb observed during the in vivo testing of modern ventricular assist devices.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2012.01515.x","type":"journal-article","created":{"date-parts":[[2012,8,6]],"date-time":"2012-08-06T09:08:40Z","timestamp":1344244120000},"page":"724-730","source":"Crossref","is-referenced-by-count":23,"title":["Reevaluation of the Harboe Assay as a Standardized Method of Assessment for the Hemolytic Performance of Ventricular Assist Devices"],"prefix":"10.1111","volume":"36","author":[{"given":"Chris H.H.","family":"Chan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Hilton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Graham","family":"Foster","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Hawkins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,8,6]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.4061\/2011\/290561"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1997.tb00369.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1995.tb02397.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2006.00256.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2006.00203.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2011.01243.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2008.00631.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1997.tb00486.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2003.07188.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2009.04.015"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e31822c4994"},{"key":"e_1_2_6_13_2","unstructured":"NCCLS.Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood; Approved Standard\u2014Third Edition.NCCLS document H15\u2010A3. Wayne PA: NCCLS 2000."},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.49.4.271"},{"key":"e_1_2_6_15_2","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1093\/clinchem\/23.4.749","article-title":"Use of tetramethylbenzidine in plasma hemoglobin assay","volume":"23","author":"Standefer JC","year":"1977","journal-title":"Clin Chem"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.3109\/00365515909060410"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/38.1.132"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.21.1.110"},{"key":"e_1_2_6_19_2","first-page":"126","article-title":"An evaluation of a spectrophotometric scanning technique for measurement of plasma hemoglobin","volume":"11","author":"Kahn SE","year":"1981","journal-title":"Ann Clin Lab Sci"},{"key":"e_1_2_6_20_2","first-page":"339","article-title":"Spectrophotometric method for quantitative plasma hemoglobin resulting from acute hemolysis","volume":"60","author":"Porter GA","year":"1962","journal-title":"J Lab Clin Med"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/24.6.696"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/85.3.342"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.2009.01249.x"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.2004.00566.x"},{"key":"e_1_2_6_25_2","unstructured":"FDA.Anticoagulant Citrate Dextrose Solution Formula A\u2014Approval Letter.2002."},{"key":"e_1_2_6_26_2","unstructured":"ASTM.F1841\u201097: Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps.2005."},{"key":"e_1_2_6_27_2","unstructured":"ASTM.F1830\u201097: Standard Practice for Selection of Blood for In Vitro Evaluation of Blood Pumps.2005."},{"key":"e_1_2_6_28_2","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1042\/bj0341460","article-title":"Estimation of oxyhaemoglobin and of methaemoglobin by a photoelectric method","volume":"34","author":"Szigeti B","year":"1940","journal-title":"Biochem J"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12275-010-0220-9"},{"key":"e_1_2_6_30_2","volume-title":"Essential Cell Biology: An Introduction to the Molecular Biology of the Cell","author":"Alberts B","year":"2003"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199808)41:2<312::AID-JBM17>3.0.CO;2-M"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2010.01051.x"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2007.00351.x"},{"key":"e_1_2_6_34_2","unstructured":"ChanHH FosterG HiltonA.Total blood function as indicated by haemolysis platelet activation and leukocyte death during in\u2010vitro testing. Paper presented at 19th Congress of the International Society for Rotary Blood Pumps Louisville KY USA September 8\u201310 2011."}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2012.01515.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2012.01515.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T02:19:54Z","timestamp":1697422794000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2012.01515.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8]]},"references-count":33,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["10.1111\/j.1525-1594.2012.01515.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2012.01515.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,8]]}}}