{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T14:56:56Z","timestamp":1785596216451,"version":"3.56.0"},"reference-count":29,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2012,9,26]],"date-time":"2012-09-26T00:00:00Z","timestamp":1348617600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2013,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We have designed a proximal\u2010fitting, anterolaterally flared, arc\u2010deposit hydroxyapatite\u2010coated anatomical femoral stem (FMS\u2010anatomic stem; KYOCERA Medical, Osaka, Japan) for cementless total hip arthroplasty (THA) for Japanese patients with dysplastic hip osteoarthritis, using a nonlinear three\u2010dimensional finite element analysis simulating loading conditions. The Anatomic Fit stem was modified in the region of the arc\u2010sprayed surface, to allow more proximal appearance of spot welds. The aim of the present study was to analyze the clinical and radiographic outcomes of patients who underwent THA using this stem. We reviewed 73 consecutive patients (79 hips; 13 men 16 hips; 60 women 63 hips; age at surgery, 57.6 years, range, 35\u201378) who underwent cementless THA using the Anatomic Fit stem, at a follow\u2010up period of 7.1 years (range, 5.1\u20139.4). Harris Hip score improved from 40.7\u2003\u00b1\u200317.1 before surgery to 91.0\u2003\u00b1\u20035.2 points at follow\u2010up. The 7.1\u2010year stem survival rate was 100%. Radiographs at follow\u2010up confirmed the stability of the femoral stems within the femoral canal in all cases, with sufficient bone ingrowth. None of the patients had subsidence of the stem exceeding 2.0\u2003mm within the femoral canal or changes in varus or valgus position of more than 2.0\u00b0. The Anatomic Fit stem provided excellent results. The nonlinear three\u2010dimensional finite element analysis demonstrated that the stem\u2010bone relative motion was 10\u2003\u00b5m at the proximal end of the stem and proximal load transfer. Our analysis confirmed reduced radiolucency around the stem, minimal subsidence, appropriate stress shielding, and promising medium\u2010term stability within the femoral canal.<\/jats:p>","DOI":"10.1111\/j.1525-1594.2012.01521.x","type":"journal-article","created":{"date-parts":[[2012,9,26]],"date-time":"2012-09-26T16:43:39Z","timestamp":1348677819000},"page":"175-182","source":"Crossref","is-referenced-by-count":12,"title":["Modified Metaphyseal\u2010Loading Anterolaterally Flared Anatomic Femoral Stem: Five\u2010 to Nine\u2010Year Prospective Follow\u2010Up Evaluation and Results of Three\u2010Dimensional Finite Element Analysis"],"prefix":"10.1111","volume":"37","author":[{"given":"Yasuo","family":"Kokubo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenzo","family":"Uchida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hisashi","family":"Oki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohei","family":"Negoro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kouki","family":"Nagamune","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shogo","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Takeno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takafumi","family":"Yayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideaki","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Sugita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ai","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hisatoshi","family":"Baba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,9,26]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"181","volume-title":"Basic Orthopaedic Biomechanics and Mechano\u2010Biology","author":"Mow VC","year":"2005"},{"key":"e_1_2_7_3_2","first-page":"927","volume-title":"Computer Assisted Radiology","author":"Bo A","year":"1995"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02488914"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-4-431-68529-6_20"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.1999.06214.x"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2009.00877.x"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2004.00017.x"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.10.014"},{"key":"e_1_2_7_10_2","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.2106\/00004623-200309000-00011","article-title":"Intermediate\u2010term results after hybrid total hip arthroplasty for the treatment of dysplastic hips","volume":"85","author":"Ito H","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-006-1099-5"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.00774"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002640000133"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199008000-00022"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200309000-00005"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2005.29065.x"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196951040-00012"},{"key":"e_1_2_7_18_2","first-page":"17","article-title":"\u201cModes of failure\u201d of cemented stem\u2010type femoral components: a radiographic analysis of loosening","volume":"141","author":"Gruen TA","year":"1979","journal-title":"Clin Orthop"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199506000-00012"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820270205"},{"key":"e_1_2_7_21_2","first-page":"27","article-title":"The various stress patterns of press\u2010fit, ingrown, and cemented femoral stems","volume":"261","author":"Huskies R","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453679308994602"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100140108"},{"key":"e_1_2_7_24_2","doi-asserted-by":"crossref","first-page":"104","DOI":"10.2106\/00004623-197153010-00009","article-title":"Sintered fiber metal composites as a basis for attachment of implants to bone","volume":"53","author":"Galante J","year":"1971","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199212000-00005"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198607000-00023"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199705000-00010"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(01)00204-4"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.10.038"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016470412331294365"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1525-1594.2012.01521.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1525-1594.2012.01521.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T10:26:56Z","timestamp":1698661616000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1525-1594.2012.01521.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,9,26]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["10.1111\/j.1525-1594.2012.01521.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1525-1594.2012.01521.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,9,26]]}}}