{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T16:59:38Z","timestamp":1762189178973,"version":"build-2065373602"},"reference-count":19,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2011,8,24]],"date-time":"2011-08-24T00:00:00Z","timestamp":1314144000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J American Geriatrics Society"],"published-print":{"date-parts":[[2011,9]]},"abstract":"<jats:p>\n                    <jats:bold>OBJECTIVES:<\/jats:bold>\n                    To estimate the potentially inappropriate use of implantable cardioverter\u2010defibrillator ICDs in older U.S. adults.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>DESIGN:<\/jats:bold>\n                    Retrospective study.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>SETTING:<\/jats:bold>\n                    The National Cardiovascular Data ICD Registry.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>PARTICIPANTS:<\/jats:bold>\n                    Forty\u2010four thousand eight hundred five individuals in the National Cardiovascular Data's ICD Registry\n                    <jats:sup>\u2122<\/jats:sup>\n                    who had received ICDs for primary prevention from January 2006 to December 2008. Individuals with a prior myocardial infarction and ejection fraction less than 30% were included.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>MEASUREMENTS:<\/jats:bold>\n                    Mortality risk was categorized using the Multicenter Automatic Defibrillator Implantation (MADIT) II risk\u2010stratification system. Low\u2010risk and very\u2010high\u2010risk individuals were considered potentially inappropriate recipients.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>RESULTS:<\/jats:bold>\n                    Of 44,805 individuals, 67% (n=29,893) were aged 65 and older, of whom 51% were aged 75 and older. A significant proportion of ICD recipients had a low risk of death (16%, n=6,969) or very high risk of nonarrhythmic death (8%, n=3,693). Potentially inappropriate ICD use was 10% in those aged 75 and older, much less than in younger groups (40%, &lt;65; 21%, 65\u201374,\n                    <jats:italic>P<\/jats:italic>\n                    &lt;.001). Although age was associated with a high risk of nonarrhythmic death, its influence was markedly attenuated after adjusting for comorbidities and timing of ICD implantation (odds ratio=1.02, 95% confidence interval=1.02\u20131.03,\n                    <jats:italic>P<\/jats:italic>\n                    &lt;.001).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>CONCLUSION:<\/jats:bold>\n                    Potentially inappropriate ICD use appears significantly less\u2014and at modest rates\u2014in older Americans than in younger age groups. Overall, almost one\u2010quarter of individuals may have received ICDs inappropriately based on their risk of death. Physicians appear to be conservatively referring older adults and wisely deferring those with high comorbid burden.\n                  <\/jats:p>","DOI":"10.1111\/j.1532-5415.2011.03542.x","type":"journal-article","created":{"date-parts":[[2011,8,31]],"date-time":"2011-08-31T20:56:57Z","timestamp":1314824217000},"page":"1589-1595","source":"Crossref","is-referenced-by-count":8,"title":["Age Differences in Primary Prevention Implantable Cardioverter\u2010Defibrillator Use in U.S. Individuals"],"prefix":"10.1111","volume":"59","author":[{"given":"Vivian","family":"Tsai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary K.","family":"Goldstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henry H.","family":"Hsia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongfei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeptha","family":"Curtis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul A.","family":"Heidenreich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"on behalf of the National Cardiovascular Data Registry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,8,24]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.04.010"},{"key":"e_1_2_7_3_2","first-page":"705","article-title":"Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States","volume":"33","author":"Kurtz SM","year":"2010","journal-title":"1993\u20132006"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2009.547"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2008.04.014"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2002.125501"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1542-474X.2005.00063.x"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCOUTCOMES.108.807123"},{"key":"e_1_2_7_9_2","unstructured":"About ICD Registry. National Cardiovascular Data Registry [on\u2010line]. Available athttp:\/\/www.ncdr.com\/WebNCDR\/ICD\/ABOUTICD.ASPXAccessed June 30 2011."},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2007.07.021"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01733-3"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013474"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2010.1915"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-7133.2009.00139.x"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2004.05.053"},{"key":"e_1_2_7_16_2","first-page":"398","article-title":"Left bundle\u2010branch block is associated with increased 1\u2010year sudden and total mortality rate in 5,517 outpatients with congestive heart failure","volume":"143","author":"Baldasseroni S","year":"2002","journal-title":"A report from the Italian Network on Congestive Heart Failure"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa043399"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCOUTCOMES.108.842369"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa033088"},{"key":"e_1_2_7_20_2","unstructured":"GarikiaptiNV ParuchuriVP AdhadukMet al. Risk Stratification of ICD Patients with Ischemic Cardiomyopathy: Do Clinical Trial Results Apply in the \u201cReal World\u201d? AHA Volume 122. Chicago IL: Circulation 2010 pp A16147."}],"container-title":["Journal of the American Geriatrics Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-5415.2011.03542.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/agsjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-5415.2011.03542.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T16:37:31Z","timestamp":1762187851000},"score":1,"resource":{"primary":{"URL":"https:\/\/agsjournals.onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-5415.2011.03542.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8,24]]},"references-count":19,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["10.1111\/j.1532-5415.2011.03542.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-5415.2011.03542.x","archive":["Portico"],"relation":{},"ISSN":["0002-8614","1532-5415"],"issn-type":[{"type":"print","value":"0002-8614"},{"type":"electronic","value":"1532-5415"}],"subject":[],"published":{"date-parts":[[2011,8,24]]}}}