{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T13:40:09Z","timestamp":1792590009566,"version":"4.5.0"},"reference-count":25,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2004,8,6]],"date-time":"2004-08-06T00:00:00Z","timestamp":1091750400000},"content-version":"vor","delay-in-days":1344,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2000,12]]},"abstract":"<jats:p><jats:bold><jats:styled-content>Purpose<\/jats:styled-content><\/jats:bold> The purpose of this study was to evaluate the influence of alloy surface microabrasion, silica coating, or microabrasion plus tin plating on the tensile bond strengths between a resin\u2010modified glass\u2010ionomer luting cement and a high\u2010noble alloy. Bond strength between the microabraded alloy specimens and conventional glass\u2010ionomer cement or resin cement were included for comparison.<\/jats:p><jats:p><jats:bold><jats:styled-content>Materials and Methods<\/jats:styled-content><\/jats:bold> One hundred twenty uniform size, disk\u2010shaped specimens were cast in a noble metal alloy and divided into 6 groups (n = 10 pairs\/group). The metal surfaces of the specimens in each group were treated and cemented as follows. Group 1: No surface treatment (as cast, control), cemented with a resin\u2010modified glass\u2010ionomer cement. Group 2: Microabrasion with 50\u2010\u03bcm aluminum oxide particles, resin\u2010modified glass\u2010ionomer cement. Group 3: A laboratory microabrasion and silica coating system, resin\u2010modified glass\u2010ionomer cement. Group 4: Microabrasion and tin\u2010plating, resin\u2010modified glass\u2010ionomer cement. Group 5: Microabrasion only, conventional glass\u2010ionomer cement. Group 6: Microabrasion and tin\u2010plating, conventional resin cement. The uniaxial tensile bond strength for each specimen pair was determined using an Instron Universal Testing Machine (Instron Corp, Canton, MA). Results were analyzed using a one\u2010way analysis of variance (\u03b1= 0.05) and a Tukey post\u2010hoc analysis.<\/jats:p><jats:p><jats:bold><jats:styled-content>Results<\/jats:styled-content><\/jats:bold> Mean bond strength: Group 1: 3.6 (\u00b11.5) MPa. Group 2: 4.2 (\u00b10.5) MPa. Group 3: 6.7 (\u00b10.9) MPa. Group 4: 10.6 (\u00b11.8) MPa. Group 5: 1.1 (\u00b10.4) MPa. Group 6: 14.6 (\u00b12.3) MPa. Group 6 was significantly stronger than Group 4. The bond strength of specimens cemented with the resin\u2010modified glass\u2010ionomer cement using microabrasion and tin\u2010plating (Group 4) was significantly stronger than all other groups except the resin cement with microabrasion and tin\u2010plating (Group 6).<\/jats:p><jats:p><jats:bold><jats:styled-content>Conclusion<\/jats:styled-content><\/jats:bold> Microabraded and tin\u2010plated alloy specimens luted with the resin\u2010modified glass\u2010ionomer cement resulted in the greatest mean tensile strengths for the resin\u2010modified glass\u2010ionomer cement groups. This strength was 73% of the mean tensile strength of microabraded specimens luted with resin cement.<\/jats:p>","DOI":"10.1111\/j.1532-849x.2000.00195.x","type":"journal-article","created":{"date-parts":[[2004,8,6]],"date-time":"2004-08-06T09:32:06Z","timestamp":1091784726000},"page":"195-200","source":"Crossref","is-referenced-by-count":9,"title":["Tensile bond strength of resin\u2010modified glass\u2010ionomer cement to microabraded and silica\u2010coated or tin\u2010plated high noble ceramic alloy"],"prefix":"10.1111","volume":"9","author":[{"given":"Jeffrey M.","family":"Swartz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard D.","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johnnie D.","family":"Overton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2004,8,6]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(92)90328-8"},{"key":"e_1_2_6_3_2","first-page":"55","article-title":"Evaluation of tin plating systems for a high\u2010noble alloy","volume":"6","author":"Imbery TA","year":"1993","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(05)80128-3"},{"key":"e_1_2_6_5_2","first-page":"59","article-title":"Tensile strength of three resin cements following two alloy surface treatments","volume":"5","author":"Imbery TA","year":"1992","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_6_2","first-page":"323","article-title":"Tensile bond strength of resin luting cement to a porcelain\u2010fusing noble alloy","volume":"9","author":"Stoknorm R","year":"1996","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(93)90232-D"},{"key":"e_1_2_6_8_2","first-page":"277","article-title":"A comparison of tensile bond strengths of resin\u2010retained prostheses made using five alloys","volume":"9","author":"Rubo JH","year":"1996","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_9_2","first-page":"192","volume-title":"Restorative Dental Materials","author":"Craig RG","year":"1997"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345970760081301"},{"key":"e_1_2_6_11_2","first-page":"587","article-title":"Proposed nomenclature for glass\u2010ionomer dental cements and related materials","volume":"25","author":"McLean JW","year":"1994","journal-title":"Quintessence Int"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(93)90283-T"},{"key":"e_1_2_6_13_2","volume-title":"R&D Department: Technical Data, Fuji Plus","author":"GC Corporation","year":"1995"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0109-5641(96)80066-2"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(98)70128-3"},{"key":"e_1_2_6_16_2","first-page":"481","volume-title":"Skinner's Science of Dental Materials, vol 1","author":"Phillips RW","year":"1991"},{"key":"e_1_2_6_17_2","first-page":"25","article-title":"Metal\u2010resin bonding","volume":"2","author":"Albers HF","year":"1991","journal-title":"Adept Report"},{"key":"e_1_2_6_18_2","first-page":"29","article-title":"A new method of attaching cast gold occlusal surfaces to acrylic resin denture teeth","volume":"24","author":"Imbery TA","year":"1993","journal-title":"Quintessence Int"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(94)90182-1"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(05)80070-8"},{"key":"e_1_2_6_21_2","first-page":"483","article-title":"Adhesive monomers for porcelain repair","volume":"2","author":"Bertolotti RL","year":"1989","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345880670020901"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.1992.tb00233.x"},{"key":"e_1_2_6_24_2","first-page":"53","article-title":"Trouble shooting etched cast restorations: Problems and solutions","volume":"3","author":"Wood M","year":"1983","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(96)90411-4"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(92)90050-K"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-849X.2000.00195.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-849X.2000.00195.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T05:40:28Z","timestamp":1697348428000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-849X.2000.00195.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,12]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2000,12]]}},"alternative-id":["10.1111\/j.1532-849X.2000.00195.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-849x.2000.00195.x","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,12]]}}}