{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T17:12:45Z","timestamp":1758474765073},"reference-count":28,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2004,8,6]],"date-time":"2004-08-06T00:00:00Z","timestamp":1091750400000},"content-version":"vor","delay-in-days":1254,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2001,3]]},"abstract":"<jats:p>Osseointegrated dental implants have been proven successful in the treatment of edentulism. The predictability of the implant\u2010supported prosthesis has also been established. Several techniques have been described for the successful restoration of the edentulous mandible: fixed\u2010detachable prostheses with either the original Br\u00e5nemark hybrid prosthesis design or conventional implant\u2010supported fixed partial dentures, implant\u2010retained overdentures, and implant\u2010supported overdentures. However, in cases of advanced ridge resorption in which facial tissue support is needed from the flanges of the prosthesis or when a removable type of prosthesis is preferred by the patient, an implant\u2010supported prosthesis is indicated. Electric discharge machining is often used in the fabrication of the bar for an implant\u2010supported overdenture. This procedure is very costly and technique sensitive. An alternative procedure to fabricate a milled\u2010bar implant\u2010supported overdenture is described. This procedure is simple and uses inexpensive equipment and materials. The milled\u2010bar minimizes lateral and rotational displacement. The overdenture incorporates attachments that provide retention, minimizing possible movement along the path of insertion. This type of prosthesis is available to a broad patient population, especially those with advanced ridge resorption, providing an excellent result at a reduced cost.<\/jats:p>","DOI":"10.1111\/j.1532-849x.2001.00046.x","type":"journal-article","created":{"date-parts":[[2004,8,6]],"date-time":"2004-08-06T09:37:11Z","timestamp":1091785031000},"page":"46-51","source":"Crossref","is-referenced-by-count":19,"title":["The implant\u2010supported milled\u2010bar mandibular overdenture"],"prefix":"10.1111","volume":"10","author":[{"given":"Daniel F.","family":"Galindo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,8,6]]},"reference":[{"key":"e_1_2_4_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-9785(81)80077-4"},{"key":"e_1_2_4_3_2","first-page":"211","article-title":"Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures","volume":"4","author":"Jemt T","year":"1989","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(90)90153-4"},{"key":"e_1_2_4_5_2","first-page":"43","article-title":"The cumulative failure rate of the Br\u00e5nemark system in the overdenture, the fixed partial, and the fixed full prosthesis design. A prospective study on 1273 fixtures","volume":"10","author":"Quirynen M","year":"1992","journal-title":"J Head Neck Pathol"},{"key":"e_1_2_4_6_2","first-page":"241","volume-title":"Tissue Integrated Prosthesis: Osseointegration in Clinical Dentistry","author":"Zarb GA","year":"1985"},{"key":"e_1_2_4_7_2","first-page":"347","article-title":"Long\u2010term follow\u2010up of osseointegrated implants in the treatment of totally edentulous jaws","volume":"5","author":"Adell R","year":"1990","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_8_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1998.090305.x"},{"key":"e_1_2_4_9_2","first-page":"253","article-title":"Implant\u2010supported overdentures: A longitudinal prospective study","volume":"13","author":"Bergendal T","year":"1998","journal-title":"J Oral Maxillofac Implants"},{"key":"e_1_2_4_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(97)70084-2"},{"key":"e_1_2_4_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(88)90355-1"},{"key":"e_1_2_4_12_2","first-page":"513","article-title":"A multicenter study of overdentures supported by Br\u00e5nemark implants","volume":"7","author":"Johns RB","year":"1992","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(91)90205-B"},{"key":"e_1_2_4_14_2","first-page":"203","article-title":"Overdentures: An alternative implant methodology for edentulous patients","volume":"6","author":"Mericske\u2010Stern R","year":"1993","journal-title":"Int J Prosthodont"},{"key":"e_1_2_4_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2000.00037.x"},{"key":"e_1_2_4_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(93)90186-R"},{"key":"e_1_2_4_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.1994.tb00161.x"},{"key":"e_1_2_4_18_2","first-page":"135","volume-title":"Contemporary Implant Dentistry","author":"Misch CE","year":"1999"},{"key":"e_1_2_4_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(00)70095-3"},{"key":"e_1_2_4_20_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1996.0032"},{"key":"e_1_2_4_21_2","first-page":"77","article-title":"The Swedish system of osseointegrated implants: Problems and complications encountered during a 4\u2010year trial period","volume":"2","author":"Worthington P","year":"1987","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_22_2","first-page":"62","article-title":"Biting force on overdenture and conventional denture patients","author":"Meng TR","year":"1983","journal-title":"J Dent Res"},{"key":"e_1_2_4_23_2","first-page":"101","article-title":"Maximum occlusal force levels in patients with osseointegrated oral implant prosthesis and patients with complete dentures","volume":"2","author":"Carr AB","year":"1987","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_24_2","first-page":"167","article-title":"Strategies to achieve fit in implant prosthodontics: A review of the literature","volume":"12","author":"Wee AG","year":"1999","journal-title":"Int J Prosthodont"},{"key":"e_1_2_4_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.1993.tb00387.x"},{"key":"e_1_2_4_26_2","first-page":"113","article-title":"Comparative accuracy of implant impression procedures","volume":"12","author":"Assif D","year":"1992","journal-title":"Int J Periodont Rest Dent"},{"key":"e_1_2_4_27_2","first-page":"216","article-title":"Accuracy of implant impression techniques","volume":"11","author":"Assif D","year":"1996","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_28_2","first-page":"885","article-title":"Accuracy of implant impression splinted techniques: Effect of splinting material","volume":"14","author":"Assif D","year":"1999","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_4_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(00)70136-3"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-849X.2001.00046.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-849X.2001.00046.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T13:18:43Z","timestamp":1697289523000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-849X.2001.00046.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,3]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2001,3]]}},"alternative-id":["10.1111\/j.1532-849X.2001.00046.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-849x.2001.00046.x","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,3]]}}}