{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T11:46:44Z","timestamp":1790077604237,"version":"4.0.1"},"reference-count":34,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2007,10,30]],"date-time":"2007-10-30T00:00:00Z","timestamp":1193702400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2008,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The reconstruction of maxillofacial bone defects by the intraoperative modeling of implants may reduce the predictability of the esthetic result, leading to more invasive surgery and increased surgical time. To improve the maxillofacial surgery outcome, modern manufacturing methods such as rapid prototyping (RP) technology and methods based on reverse engineering (RE) and medical imaging data are applicable to the manufacture of custom\u2010made maxillary prostheses. After acquisition of data, an individual computer\u2010based 3D model of the bony defect is generated. These data are transferred into RE software to create the prosthesis using a computer\u2010aided design (CAD) model, which is directed into the RP machine for the production of the physical model. The precise fit of the prosthesis is evaluated using the prosthesis and skull models. The prosthesis is then directly used in investment casting such as \u201cQuick Cast\u201d pattern to produce the titanium model. In the clinical reports presented here, reconstructions of two patients with large maxillary bone defects were performed using this new method. The custom prostheses perfectly fit the defects during the operations, and surgery time was reduced. These cases show that the prefabrication of a prosthesis using modern manufacturing technology is an effective method for maxillofacial defect reconstruction.<\/jats:p>","DOI":"10.1111\/j.1532-849x.2007.00266.x","type":"journal-article","created":{"date-parts":[[2007,10,30]],"date-time":"2007-10-30T18:25:22Z","timestamp":1193768722000},"page":"135-140","source":"Crossref","is-referenced-by-count":49,"title":["Individually Prefabricated Prosthesis for Maxilla Reconstruction"],"prefix":"10.1111","volume":"17","author":[{"given":"Sekou","family":"Singare","sequence":"first","affiliation":[{"name":"Key Laboratory of Biomedical Information Engineering of the Ministry of Education, and Institute of Biomedical Engineering, Xi'an Jiaotong University  Xi'an China"},{"name":"Department of Mechatronic Engineering, Dongguan University of Technology  Guangdong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaxiong","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Lab for Manufacturing Systems Engineering"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dichen","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Lab for Manufacturing Systems Engineering"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bingheng","family":"Lu","sequence":"additional","affiliation":[{"name":"State Key Lab for Manufacturing Systems Engineering"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanhu","family":"He","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, School of Stomatology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,10,9]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.scs.0000205981.44844.fd"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.PRS.0000160691.63029.74"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MLG.0000181512.55041.7D"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.SCS.0000157306.54667.68"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.oraloncology.2005.03.006"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.137.4.447"},{"key":"e_1_2_7_8_2","unstructured":"KahlerDM ZuraRD MallikK:Computer guided placement of iliosacral screws compared to standard fluoroscopic technique. 5th Symposium on CAOS Computer Assisted Orthopaedic Surgery.2002 Davos Switzerland"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-2391(96)90630-8"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(05)80869-0"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001665-200311000-00002"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2004.06.001"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1108\/13552540510589485"},{"key":"e_1_2_7_14_2","first-page":"79","article-title":"Integration of 3\u2010D medical imaging and rapid prototyping to create stereolithographic models","volume":"16","author":"Barker TM","year":"1993","journal-title":"Aust Phys Eng Sci Med"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01627975"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-5182(99)80007-9"},{"key":"e_1_2_7_17_2","first-page":"261","article-title":"Three dimensional imaging and computer\u2010designed prostheses in the evaluation and management of orbitocranial deformities","volume":"9","author":"Ellis DS","year":"1992","journal-title":"Adv Ophthalmic Plast Reconstr Surg"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-5182(05)80007-1"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-199808000-00002"},{"key":"e_1_2_7_20_2","first-page":"706","article-title":"Principles and applications of computer\u2010aided design and computer\u2010aided manufacturing (CAD\/CAM) technology in orthopaedics","volume":"19","author":"Goh JC","year":"1990","journal-title":"Ann Acad Med Singapore"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(98)80060-X"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1108\/13552540310477481"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(04)16935-3"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1080\/030919099294401"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2005.03.016"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.2176\/nmc.38.746"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0007-1226(94)90121-X"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(98)80059-3"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001665-200311000-00014"},{"key":"e_1_2_7_30_2","first-page":"854","article-title":"Iliac crest internal oblique osteomusculocutaneous free flap reconstruction of the postablative palatomaxillary defect","volume":"127","author":"Genden EM","year":"2001","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/0007-1226(90)90115-G"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.130.12.1388"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0194-59980300480-7"},{"key":"e_1_2_7_34_2","doi-asserted-by":"publisher","DOI":"10.1002\/hed.10181"},{"key":"e_1_2_7_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200102150-00012"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-849X.2007.00266.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-849X.2007.00266.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-849X.2007.00266.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T19:09:24Z","timestamp":1696187364000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-849X.2007.00266.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,2]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2008,2]]}},"alternative-id":["10.1111\/j.1532-849X.2007.00266.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-849x.2007.00266.x","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,2]]}}}