{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T19:45:15Z","timestamp":1780602315278,"version":"3.54.1"},"reference-count":31,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2010,11,5]],"date-time":"2010-11-05T00:00:00Z","timestamp":1288915200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Prosthodontics"],"published-print":{"date-parts":[[2010,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Prosthodontic rehabilitation of a patient with an atrophic edentulous mandible presents a significant challenge in restoring esthetics and function. The purpose of this clinical report is to describe fracture of an atrophic edentulous mandible opposing maxillary natural dentition in association with endosseous dental implants. The patient received two wide\u2010diameter implants in the anterior mandible for an implant\u2010assisted mandibular overdenture, in which the implants penetrated the inferior border of the mandible for bicortical stabilization. Three months following implant placement surgery, the patient experienced pain, swelling, and intraoral purulent drainage around the right implant. Panoramic radiograph revealed a fracture of the mandible through the right implant site and signs of infection around the left implant. The implants were removed surgically, and open reduction and fixation of the fracture site were undertaken using a titanium bone fixation plate. This clinical report demonstrates that placement of wide\u2010diameter implants in conjunction with bicortical penetration in a severely atrophic edentulous mandible can risk fracture of the mandible.<\/jats:p>","DOI":"10.1111\/j.1532-849x.2010.00646.x","type":"journal-article","created":{"date-parts":[[2010,11,7]],"date-time":"2010-11-07T11:01:16Z","timestamp":1289127676000},"page":"625-629","source":"Crossref","is-referenced-by-count":25,"title":["Mandibular Fracture in Conjunction with Bicortical Penetration, Using Wide\u2010Diameter Endosseous Dental Implants"],"prefix":"10.1111","volume":"19","author":[{"given":"Won\u2010suk","family":"Oh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleni D.","family":"Roumanas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Beumer III","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,11,5]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008505-199304000-00009"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0278-2391(95)90231-7"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-2391(00)90917-0"},{"key":"e_1_2_5_5_2","first-page":"563","article-title":"The extremely resorbed mandible: a comparative prospective study of 2\u2010year results with 3 treatment strategies","volume":"19","author":"Stellingsma K","year":"2004","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910708600315"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(99)70208-8"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910408300809"},{"key":"e_1_2_5_9_2","first-page":"275","article-title":"Influence of prosthetic parameters on the survival and complication rates of short implants","volume":"21","author":"Tawil G","year":"2006","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_10_2","first-page":"299","article-title":"Vertical distraction of the severely resorbed edentulous mandible: an assessment of treatment outcome","volume":"23","author":"Raghoebar GM","year":"2008","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0278-2391(90)90401-M"},{"key":"e_1_2_5_12_2","first-page":"427","article-title":"Management of mandibular fractures in patients with endosseous implants","volume":"6","author":"Tolman DE","year":"1991","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_13_2","first-page":"401","article-title":"Mandibular fracture through an endosseous implant","volume":"7","author":"Shonberg DC","year":"1992","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001665-199304000-00008"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.dmfr.4600541"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(94)90092-2"},{"key":"e_1_2_5_17_2","first-page":"609","article-title":"Quantification of bone resorption in the interforaminal region of the atrophic mandible","volume":"22","author":"Blahout RM","year":"2007","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_18_2","first-page":"186","article-title":"Heat generation during implant site preparation: an in vitro study","volume":"12","author":"Cordioli G","year":"1997","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_19_2","first-page":"536","article-title":"Oral implant surfaces: Part 1\u2013review focusing on topographic and chemical properties of different surfaces and in vivo responses to them","volume":"17","author":"Albrektsson T","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/039463200702001s06"},{"key":"e_1_2_5_21_2","first-page":"271","article-title":"A three\u2010dimensional finite element study on two versus four implants in an edentulous mandible","volume":"7","author":"Meijer HJ","year":"1994","journal-title":"Int J Prosthodont"},{"key":"e_1_2_5_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(96)90442-4"},{"key":"e_1_2_5_23_2","first-page":"111","article-title":"Stress and strain distribution behavior in the bone due to the effect of cancellous bone, dental implant material and the bone height","volume":"12","author":"Hedia HS","year":"2002","journal-title":"Biomed Mater Eng"},{"key":"e_1_2_5_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00113-1"},{"key":"e_1_2_5_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345940730010801"},{"key":"e_1_2_5_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(96)80036-1"},{"key":"e_1_2_5_27_2","first-page":"59","article-title":"Bicortically stabilized implant load transfer","volume":"18","author":"Jeong CM","year":"2003","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00208.x"},{"key":"e_1_2_5_29_2","doi-asserted-by":"publisher","DOI":"10.4012\/dmj.24.219"},{"key":"e_1_2_5_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2005.06.019"},{"key":"e_1_2_5_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2003.08.008"},{"key":"e_1_2_5_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2008.00322.x"}],"container-title":["Journal of Prosthodontics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-849X.2010.00646.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-849X.2010.00646.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T18:57:11Z","timestamp":1697309831000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-849X.2010.00646.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,5]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["10.1111\/j.1532-849X.2010.00646.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-849x.2010.00646.x","archive":["Portico"],"relation":{},"ISSN":["1059-941X","1532-849X"],"issn-type":[{"value":"1059-941X","type":"print"},{"value":"1532-849X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,5]]}}}