{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T02:22:17Z","timestamp":1783995737256,"version":"3.55.0"},"reference-count":15,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2004,4,29]],"date-time":"2004-04-29T00:00:00Z","timestamp":1083196800000},"content-version":"vor","delay-in-days":1702,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[1999,9]]},"abstract":"<jats:p><jats:bold>Objective<\/jats:bold>This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS).<\/jats:p><jats:p><jats:bold>Study Design<\/jats:bold>An<jats:italic>in vitro,<\/jats:italic>paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS.<\/jats:p><jats:p><jats:bold>Animal or Sample Population<\/jats:bold>Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges.<\/jats:p><jats:p><jats:bold>Methods<\/jats:bold>The two methods of repair and normal intact specimens were evaluated in single cycle\u2010to\u2010failure loading. Yield failure was defined to occur at the first notable discontinuity (&gt;50 N) in the load\u2010displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment\u2010fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement.<\/jats:p><jats:p><jats:bold>Results<\/jats:bold>Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW\u2010repaired than for the LS\u2010repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW\u2010repaired osteotomies.<\/jats:p><jats:p><jats:bold>Conclusions<\/jats:bold>Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load\u2010to\u2010failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.<\/jats:p><jats:p><jats:bold>Clinical Relevance<\/jats:bold>Our study indicates the initial strength of repair is greater following transfixation wiring than for lag screw fixation. Knowledge of the mechanical properties of these methods of fixation should aid the surgeon contemplating repair of mid\u2010body fractures of the proximal sesamoid bones.<\/jats:p>","DOI":"10.1111\/j.1532-950x.1999.00355.x","type":"journal-article","created":{"date-parts":[[2004,4,29]],"date-time":"2004-04-29T15:05:02Z","timestamp":1083251102000},"page":"355-367","source":"Crossref","is-referenced-by-count":7,"title":["An<i>In Vitro<\/i>Biomechanical Comparison of Two Fixation Methods for Transverse Osteotomies of the Medial Proximal Forelimb Sesamoid Bones in Horses"],"prefix":"10.1111","volume":"28","author":[{"given":"David A.","family":"Wilson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin G.","family":"Keegan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William L.","family":"Carson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2004,4,29]]},"reference":[{"issue":"11","key":"e_1_2_5_2_2","first-page":"16","article-title":"Fractures in Thoroughbred race horses","volume":"78","author":"Krook L","year":"1988","journal-title":"Cornell Vet"},{"key":"e_1_2_5_3_2","first-page":"267","article-title":"Injuries sustained during racing at racetracks in the U.S. in 1992","volume":"39","author":"Wilson JH","year":"1993","journal-title":"Proc Am Assoc Equine Practnr"},{"key":"e_1_2_5_4_2","doi-asserted-by":"crossref","first-page":"620","DOI":"10.2460\/javma.1994.204.04.620","article-title":"Prevalence of, and factors associated with, musculoskeletal racing injuries of Thoroughbreds","volume":"204","author":"Peloso JG","year":"1994","journal-title":"J Am Vet Med Assoc"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.1994.tb04395.x"},{"key":"e_1_2_5_6_2","first-page":"S684","article-title":"Proximal sesamoid bone fractures in horses: Current treatments and prognoses","volume":"7","author":"Bukowiecki CF","year":"1985","journal-title":"Comp Conint Educ Pract Vet"},{"key":"e_1_2_5_7_2","first-page":"163","volume-title":"Equine Fracture Repair","author":"Bertone AL","year":"1996"},{"key":"e_1_2_5_8_2","first-page":"32","article-title":"Compression screw fixation of proximal sesamoid fractures","volume":"2","author":"Fackelman GE","year":"1978","journal-title":"J Equine Med Surg"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1991.tb00299.x"},{"key":"e_1_2_5_10_2","doi-asserted-by":"crossref","first-page":"606","DOI":"10.2460\/javma.1991.199.05.606","article-title":"Lag screw and cancellous bone graft fixation of transverse proximal sesamoid bone fractures in horses: 25 cases (1983\u20131989)","volume":"199","author":"Henninger RW","year":"1991","journal-title":"J Am Vet Med Assoc"},{"key":"e_1_2_5_11_2","first-page":"536","volume-title":"Equine Exercise Physiology 2","author":"Seeherman HJ","year":"1987"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1159\/000147439"},{"key":"e_1_2_5_13_2","doi-asserted-by":"crossref","first-page":"675","DOI":"10.2460\/ajvr.1993.54.05.675","article-title":"External loads on the limbs of jumping horses at take\u2010off and landing","volume":"54","author":"Schamhardt HC","year":"1993","journal-title":"Am J Vet Res"},{"key":"e_1_2_5_14_2","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.2460\/ajvr.1992.53.7.1203","article-title":"Evaluation of support bandaging during measurement of proximal sesamoidean ligament strain in horses by use of a mercury strain gauge","volume":"53","author":"Keegan KG","year":"1992","journal-title":"Am J Vet Res"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1987.tb00923.x"},{"key":"e_1_2_5_16_2","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.2460\/ajvr.1991.52.08.1350","article-title":"Quantitative evaluation of the remodeling response of the proximal sesamoid bones to training\u2010related stimuli in Thoroughbreds","volume":"52","author":"Young DR","year":"1991","journal-title":"Am J Vet Res"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.1999.00355.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.1999.00355.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T07:35:39Z","timestamp":1734334539000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.1999.00355.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,9]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1999,9]]}},"alternative-id":["10.1111\/j.1532-950X.1999.00355.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.1999.00355.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,9]]}}}