{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T16:33:58Z","timestamp":1782491638624,"version":"3.54.5"},"reference-count":20,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,2,17]],"date-time":"2005-02-17T00:00:00Z","timestamp":1108598400000},"content-version":"vor","delay-in-days":47,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2005,1]]},"abstract":"<jats:p><jats:bold>Objective\u2014<\/jats:bold> To determine failure strength, stiffness, and failure mode of 4 suture materials in equine linea alba.<\/jats:p><jats:p><jats:bold>Study Design\u2014<\/jats:bold> Randomized complete block design.<\/jats:p><jats:p><jats:bold>Sample Population\u2014<\/jats:bold> Linea albas collected from 12 adult horses (mean weight, 475\u2003kg; mean age, 10 years).<\/jats:p><jats:p><jats:bold>Methods\u2014<\/jats:bold> The ventral abdominal fascia, including the linea alba, was collected and bisected along the linea alba into right and left halves. Each half was divided into four, 5\u2010cm sections extending from the umbilicus cranially, and randomly assigned to 1 of 4 suture materials: 2 polydioxanone (2 PD), 3 polyglactin 910 (3 PG), 6 polyglactin 910 (6 PG), and 7 polydioxanone (7 PD). A single cycle to failure test was performed on each specimen at a distraction rate of 100\u2003mm\/min. Differences in failure strength and stiffness for the materials were evaluated using a mixed linear model with significance set at <jats:italic>P<\/jats:italic>&lt;.05.<\/jats:p><jats:p><jats:bold>Results\u2014<\/jats:bold> In 94 of 96 test sections, constructs failed by suture failure. There were significant differences in failure strength (<jats:italic>P<\/jats:italic>&lt;.0001) and stiffness (<jats:italic>P<\/jats:italic>&lt;.001) among the suture\/tissue constructs. 7 PD had the highest breaking strength (316.8\u2003N) followed by 6 PG (281.3\u2003N), 3 PG (229.9\u2003N), and 2 PD (193.0\u2003N). Six PG had the largest stiffness (14\u2003N\/mm) followed by 3 PG (12.7\u2003N\/mm), 7 PD (10.1\u2003N\/mm), and 2 PD (7.2\u2003N\/mm). Suture breaking strength and stiffness were not affected by linea or fascia thickness, individual horse, half of the linea alba, or abdominal wall position. Eighty\u2010five (90.4%) suture loops failed adjacent the knot.<\/jats:p><jats:p><jats:bold>Conclusions\u2014<\/jats:bold> When tested in single cycle to failure, suture material was more likely to fail than the linea alba. Larger suture materials had higher breaking strengths than smaller suture materials and stiffness was also affected by suture material and size.<\/jats:p><jats:p><jats:bold>Clinical Relevance\u2014<\/jats:bold> Given its high initial breaking strength and its relatively longer in vivo strength retention, 7 PD seems an appropriate choice of suture material for closure of the equine linea alba when maximal short\u2010term failure strength is desired.<\/jats:p>","DOI":"10.1111\/j.1532-950x.2005.00004.x","type":"journal-article","created":{"date-parts":[[2005,2,17]],"date-time":"2005-02-17T20:13:53Z","timestamp":1108671233000},"page":"18-23","source":"Crossref","is-referenced-by-count":32,"title":["An In Vitro Biomechanical Comparison of the Breaking Strength and Stiffness of Polydioxanone (Sizes 2, 7) and Polyglactin 910 (Sizes 3, 6) in the Equine Linea Alba"],"prefix":"10.1111","volume":"34","author":[{"given":"Erin E.","family":"Fierheller","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David G.","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,2,17]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"435","article-title":"A study of the biomechanical properties of the adult equine linea alba","volume":"23","author":"Trostle SS","year":"1994","journal-title":"relationship of tissue bite size and suture material to breaking strength"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1992.tb01711.x"},{"key":"e_1_2_6_4_2","first-page":"507","article-title":"Sutures Part I. The purpose of sutures and available suture materials","volume":"4","author":"Bellenger CR","year":"1982","journal-title":"Compend Contin Educ Pract Vet"},{"key":"e_1_2_6_5_2","first-page":"587","article-title":"Sutures Part II. The use of sutures and alternative methods of closure","volume":"4","author":"Bellenger CR","year":"1982","journal-title":"Compend Contin Educ Pract Vet"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.1988.tb01559.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1999.00442.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2000.00145.x"},{"key":"e_1_2_6_9_2","first-page":"450","article-title":"Surgical and postoperative factors influencing short\u2010term survival of horses following small intestinal resection","volume":"34","author":"Morton J","year":"2002","journal-title":"92 cases (1994\u20132001)"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1995.tb01362.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1989.tb01100.x"},{"key":"e_1_2_6_12_2","first-page":"639","article-title":"Factors affecting incisional complication rates associated with colic surgery in horses","volume":"195","author":"Kobluk CN","year":"1989","journal-title":"78 cases (1983\u20131985)"},{"key":"e_1_2_6_13_2","first-page":"444","article-title":"Equine surgical colic","volume":"34","author":"French NP","year":"2002","journal-title":"risk factors for postoperative complications"},{"key":"e_1_2_6_14_2","first-page":"75","article-title":"Closure of the abdominal wall; how and why?","volume":"156","author":"Wadstr\u00f6m J","year":"1990","journal-title":"Acta Chir Scand"},{"key":"e_1_2_6_15_2","first-page":"91","volume-title":"Equine Surgery","author":"Blackford LW","year":"1999"},{"key":"e_1_2_6_16_2","first-page":"873","article-title":"The burst abdominal wound","volume":"63","author":"Jenkins TPN","year":"1976","journal-title":"a mechanical approach"},{"key":"e_1_2_6_17_2","first-page":"1","article-title":"Tensile strength of twelve types of knots employed in surgery using different suture materials","volume":"142","author":"Tera H","year":"1976","journal-title":"Acta Chir Scand"},{"key":"e_1_2_6_18_2","first-page":"366","article-title":"Current practice of abdominal fascial closure","volume":"44","author":"Hodgson NC","year":"2001","journal-title":"a survey of Ontario general surgeons"},{"key":"e_1_2_6_19_2","first-page":"421","article-title":"Closure of the abdominal midline fascia","volume":"67","author":"Rucinski J","year":"2001","journal-title":"meta-analysis delineates the optimal technique"},{"key":"e_1_2_6_20_2","first-page":"283","volume-title":"Biomechanics and biology of movement. Champagne, IL","author":"Anderson DD","year":"2000"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(90)90050-Z"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950x.2005.00004.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950x.2005.00004.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T05:50:57Z","timestamp":1697089857000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950x.2005.00004.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2005,1]]}},"alternative-id":["10.1111\/j.1532-950x.2005.00004.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2005.00004.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,1]]}}}