{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T19:45:47Z","timestamp":1794599147042,"version":"4.9.1"},"reference-count":19,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2008,7,31]],"date-time":"2008-07-31T00:00:00Z","timestamp":1217462400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2008,8]]},"abstract":"<jats:p><jats:bold>Objective\u2014<\/jats:bold>To compare biomechanical properties of 6 suture configurations using a large diameter polyester prosthesis in the muscular process (MP) of the arytenoid cartilage and to determine failure mode.<\/jats:p><jats:p><jats:bold>Study Design\u2014<\/jats:bold>Experimental study.<\/jats:p><jats:p><jats:bold>Sample Population\u2014<\/jats:bold>Cadaveric equine larynges (n=121).<\/jats:p><jats:p><jats:bold>Methods\u2014<\/jats:bold>Suture configurations (4 single, 2 double) were inserted, and then constructs were tested in a single\u2010cycle to failure at a 100\u2003mm\/min distraction. Load deformation curves were generated to assess the biomechanical properties of each construct. A 1\u2010way ANOVA was used to compare the mean differences in construct failure force, cricoarytenoid joint (CAJ) disarticulation force, and energy stored at failure. A 2\u2010sample t\u2010test was used to compare single versus double suture patterns and a Fisher's exact test was used to compare failure mode.<\/jats:p><jats:p><jats:bold>Results\u2014<\/jats:bold>Both construct and CAJ failure force were significantly greater (<jats:italic>P<\/jats:italic>&lt;.05) for double suture patterns compared with single suture patterns; however, there were no significant differences in energy stored at construct failure. Failure at the MP accounted for \u226550% of construct failures for 3 of the single suture patterns and 1 of the double suture patterns tested. The remaining 2 patterns had an increased frequency of clamp failures as well as failure of the cricoid cartilage.<\/jats:p><jats:p><jats:bold>Conclusions\u2014<\/jats:bold>Sutures that sufficiently engage the spine of the MP alone or in conjunction with a second suture were found to be biomechanically superior.<\/jats:p><jats:p><jats:bold>Clinical Relevance\u2014<\/jats:bold>Engaging the spine of the MP appears to result in the most biomechanically sound laryngeal construct.<\/jats:p>","DOI":"10.1111\/j.1532-950x.2008.00423.x","type":"journal-article","created":{"date-parts":[[2008,7,31]],"date-time":"2008-07-31T21:15:28Z","timestamp":1217538928000},"page":"580-587","source":"Crossref","is-referenced-by-count":27,"title":["Biomechanical Comparison of Six Suture Configurations Using a Large Diameter Polyester Prosthesis in the Muscular Process of the Equine Arytenoid Cartilage"],"prefix":"10.1111","volume":"37","author":[{"given":"JENNY R.","family":"KELLY","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JAMES","family":"CARMALT","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"STEVEN","family":"HENDRICK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DAVID G.","family":"WILSON","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"RYAN","family":"SHOEMAKER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,7,31]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"157","article-title":"Use of a prosthetic device for surgical correction of laryngeal hemiplegia in horses","volume":"157","author":"Marks D","year":"1970","journal-title":"J Am Vet Med Assoc"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/vr.150.15.481"},{"key":"e_1_2_6_4_2","first-page":"472","article-title":"The value of surgical treatment of laryngeal hemiplegia in horses","volume":"13","author":"Durcharme N","year":"1991","journal-title":"Compend Contin Educ Pract Vet"},{"key":"e_1_2_6_5_2","first-page":"77","volume-title":"Havemeyer Foundation Monograph Series No 11","author":"Derksen FJ","year":"2004"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-0813.1983.tb02812.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"crossref","first-page":"114","DOI":"10.2460\/ajvr.1990.51.01.114","article-title":"Effects of age and prosthesis material on in vitro cartilage retention of laryngoplasty prostheses in horses","volume":"51","author":"Dean PW","year":"1990","journal-title":"Am J Vet Res"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00111.x"},{"key":"e_1_2_6_9_2","first-page":"115","article-title":"Arytenoid cartilage retention of laryngoplasty in horses\u2014in vitro assessment of effect of age, placement site, and implantation technique","volume":"47","author":"Herde I","year":"2001","journal-title":"Proc Am Assoc Equine Pract"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.2746\/042516400777611991"},{"key":"e_1_2_6_11_2","unstructured":"GoodallCLM BirksEK SullinsKE et al: Nylon suture secured with a precision crimping device: an alternative for laryngoplasty prosthesis in Proceedings of the American College of Veterinary Surgeons Symposium Washington DC 2003 pp8\u20139"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00086.x"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/B1-41-600123-9\/50046-2"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-0739(02)00072-X"},{"key":"e_1_2_6_15_2","first-page":"63","volume-title":"Havemeyer Foundation Monograph Series No 11","author":"Dixon PM","year":"2004"},{"key":"e_1_2_6_16_2","first-page":"66","volume-title":"Havemeyer Foundation Monograph Series No 11","author":"Parente EJ","year":"2004"},{"key":"e_1_2_6_17_2","first-page":"191","article-title":"Biomechanical evaluation of suture pullout from canine arytenoids cartilages","volume":"33","author":"Matthews KG","year":"2004","journal-title":"effects of hole diameter, suture configuration, suture size, and distraction rate"},{"key":"e_1_2_6_18_2","unstructured":"ParenteEJ: Surgical variations of laryngoplasty in Proceedings of the American College of Veterinary Surgeons Symposium San Diego CA 2005 pp121\u2013122"},{"key":"e_1_2_6_19_2","unstructured":"BoswellJC SchrammeMC SchumacherJ et al: An in vitro study of two surgical variables for suture placement through the muscular process of the arytenoid cartilage for prosthetic laryngoplasty in the horse in Proceedings of the 9th Annual Scientific Meeting European College of Veterinary Surgeons Berne Switzerland 2000 pp168\u2013170"},{"key":"e_1_2_6_20_2","unstructured":"DucharmeNG: Review of laryngeal hemiplegia (RLN) treatments in Proceedings of the Western Canadian Association of Equine Practitioners Calgary Canada 2007 pp1\u201334"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2008.00423.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2008.00423.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T22:30:42Z","timestamp":1709159442000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2008.00423.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7,31]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008,8]]}},"alternative-id":["10.1111\/j.1532-950X.2008.00423.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2008.00423.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,7,31]]}}}