{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T11:41:44Z","timestamp":1784720504425,"version":"3.55.0"},"reference-count":30,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2009,1]]},"abstract":"<jats:p><jats:bold>Objective\u2014<\/jats:bold> To compare the axial compression stiffness of osteotomized canine tibiae stabilized with Slocum, Securos, or Synthes plates after a tibial plateau leveling osteotomy (TPLO) procedure.<\/jats:p><jats:p><jats:bold>Study Design\u2014<\/jats:bold> In vitro, paired comparison of cadaveric tibial constructs subjected to mechanical testing under an axial load.<\/jats:p><jats:p><jats:bold>Sample Population\u2014<\/jats:bold> Canine tibiae (n=16 pairs) from skeletally mature male and female dogs of various breeds (18\u201355\u2003kg).<\/jats:p><jats:p><jats:bold>Methods\u2014<\/jats:bold> Tibial pairs (n=16) were randomly assigned to 1 of 2 study cohorts (n=8 pairs\/cohort): cohort 1, tibial osteotomy stabilization with a Slocum or a Securos plate, or cohort 2, tibial osteotomy stabilization with a Slocum or a Synthes plate. One tibia from each pair was stabilized with 1 of each plate design assigned to the cohort after TPLO. A 3.2\u2003mm osteotomy gap was maintained during plate application in all constructs. Load and axial displacement were recorded while constructs were loaded to 2000\u2003N in axial compression. Failure loads were not reported because no distinct yield point or failure point was evident within the load range for many specimens. Failure modes were recorded for each construct, and photographs of typical failures were obtained. Stiffness (N\/mm) was calculated from load\u2013displacement curves. Paired comparisons of mean stiffness were performed within study groups using a paired t\u2010test. Significance was set at <jats:italic>P<\/jats:italic>&lt;.05.<\/jats:p><jats:p><jats:bold>Results\u2014<\/jats:bold> The mean construct stiffnesses for the Slocum (383\u00b1183\u2003N\/mm) and Securos (258\u00b164.1\u2003N\/mm) constructs were not significantly different (<jats:italic>P<\/jats:italic>=.164; power=0.566). The mean construct stiffness for the Synthes constructs (486\u00b191.0\u2003N\/mm) was significantly greater than that of the Slocum constructs (400\u00b1117\u2003N\/mm); <jats:italic>P<\/jats:italic>=.0468. Modes of failure for the Slocum (16\/16) and Securos (8\/8) constructs included plastic deformation of the implant with valgus deformity combined with fibular luxation (2\/16 Slocum; 1\/8 Securos) or fibular fracture (2\/16 Slocum; 4\/8 Securos). Most Synthes constructs underwent elastic deformation (7\/8). One Synthes construct fractured in the saggital plane through the tibial plateau depression at the point of load application.<\/jats:p><jats:p><jats:bold>Conclusions\u2014<\/jats:bold> The Slocum and Securos plate\/tibia construct have similar stiffness, whereas the Synthes\/tibia constructs are significantly stiffer than the Slocum\/tibia constructs. Modes of fixation failure observed in this model were consistent with TPLO fixation failures observed clinically.<\/jats:p><jats:p><jats:bold>Clinical relevance\u2014<\/jats:bold> Construct stiffness in axial load varies with implant type. Implants that confer higher stiffness to the construct may result in greater fixation stability in tibial metaphyseal osteotomies.<\/jats:p>","DOI":"10.1111\/j.1532-950x.2008.00464.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T12:07:38Z","timestamp":1230811658000},"page":"40-48","source":"Crossref","is-referenced-by-count":17,"title":["Biomechanical Comparison of Two Alternative Tibial Plateau Leveling Osteotomy Plates with the Original Standard in an Axially Loaded Gap Model: An In Vitro Study"],"prefix":"10.1111","volume":"38","author":[{"suffix":"II","given":"PAUL A.","family":"KLOC","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MICHAEL P.","family":"KOWALESKI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ALAN S.","family":"LITSKY","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"NANCY O.","family":"BROWN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KENNETH A.","family":"JOHNSON","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_6_2_2","volume-title":"Tibial Plateau Leveling Osteotomy Certification Course","author":"Slocum B","year":"2000"},{"key":"e_1_2_6_3_2","first-page":"278","article-title":"Effect of tibial plateau leveling on cranial and caudal tibial thrusts in canine cranial cruciate\u2010deficient stifles","volume":"30","author":"Warzee CC","year":"2001","journal-title":"an in vitro experimental study"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2006.00175.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2004.04066.x"},{"key":"e_1_2_6_6_2","first-page":"184","article-title":"Surgical and postoperative complications associated with tibial plateau leveling osteotomy in dogs with cranial cruciate ligament rupture","volume":"222","author":"Pacchiana PD","year":"2003","journal-title":"397 cases (1998\u20132001)"},{"key":"e_1_2_6_7_2","first-page":"1726","article-title":"Complications with and owner assessment of the outcome of tibial plateau leveling osteotomy for treatment of cranial cruciate ligament rupture in dogs","volume":"222","author":"Priddy NH","year":"2003","journal-title":"193 cases (1997\u20132001)"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.00893"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1632797"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.67.7.1258"},{"key":"e_1_2_6_11_2","first-page":"57","volume-title":"Standard Test Method for Static Bending Properties of Metallic Bone Plates, ASTM F382\u201086 in 1994 Annual Book of ASTM Standards","author":"American Society for Testing and Materials","year":"1994"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(03)00253-5"},{"key":"e_1_2_6_13_2","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1007\/978-3-642-60288-7","volume-title":"Manual of Internal Fixation in Small Animals","author":"Brinker WO","year":"1998"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.023"},{"key":"e_1_2_6_15_2","first-page":"50","article-title":"Locking plate technology","volume":"20","author":"Greiwe RM","year":"2007","journal-title":"current concepts"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200409000-00003"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(01)00127-9"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.020"},{"key":"e_1_2_6_19_2","doi-asserted-by":"crossref","first-page":"893","DOI":"10.2106\/00004623-199173060-00011","article-title":"The role of supplemental lag screw fixation for open fractures of the tibial shaft treated with external fixation","volume":"73","author":"Krettek C","year":"1991","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197111000-00026"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197658020-00005"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453677608991984"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100070203"},{"key":"e_1_2_6_24_2","first-page":"431","article-title":"Less rigid internal fixation plates","volume":"1","author":"Woo SL","year":"1984","journal-title":"historical perspectives and new concepts"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-198701040-00010"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200402000-00040"},{"key":"e_1_2_6_27_2","first-page":"540","article-title":"Unstable proximal extraarticular tibia fractures","volume":"18","author":"Peindl RD","year":"2004","journal-title":"a biomechanical evaluation of four methods of fixation"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2004.04.001"},{"key":"e_1_2_6_29_2","first-page":"358","article-title":"Biomechanical testing of the locking compression plate","volume":"38","author":"Ahmad M","year":"2007","journal-title":"when does the distance between bone and implant significantly reduce construct stability?"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199601000-00002"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00389.x"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2008.00464.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2008.00464.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T15:51:27Z","timestamp":1697557887000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2008.00464.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12,30]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,1]]}},"alternative-id":["10.1111\/j.1532-950X.2008.00464.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2008.00464.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,12,30]]}}}