{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:37:11Z","timestamp":1793407031339,"version":"4.5.0"},"reference-count":24,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2009,9,24]],"date-time":"2009-09-24T00:00:00Z","timestamp":1253750400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2009,10]]},"abstract":"<jats:p><jats:bold>Objective\u2014<\/jats:bold> To describe the use of a 3.5\/2.7\u2003mm CastLess Plate (CLP) for pancarpal arthrodesis (PCA) in dogs.<\/jats:p><jats:p><jats:bold>Study Design\u2014<\/jats:bold> Case series.<\/jats:p><jats:p><jats:bold>Animals\u2014<\/jats:bold> Dogs with traumatic\/degenerative carpal disease (n=11).<\/jats:p><jats:p><jats:bold>Methods\u2014<\/jats:bold> Records (September 2006\u2013July 2007) of dogs that had PCA using a 3.5\/2.7\u2003mm CLP were reviewed to determine intra\u2010 and postoperative complications and use of external coaptation. Follow\u2010up (\u226512 months) was obtained by telephone interview of owners.<\/jats:p><jats:p><jats:bold>Results\u2014<\/jats:bold> Thirteen PCA procedures were performed; 5 intraoperative complications occurred in 4 procedures and included iatrogenic metacarpal fissure fracture (2), inability to remove an alignment pin (1), and poor distal plate position (2). External coaptation was used in 4 dogs: concomitant or iatrogenic injuries (3), bilateral PCA (1), for 3\u20136 weeks. Clinical evaluation 6\u201324 weeks postoperatively revealed iatrogenic metacarpal fractures to have healed and that 1 postoperative complication (infection) developed. Telephone follow up for 10 dogs (mean, 14 months; range, 12\u201320 months) revealed no further problems.<\/jats:p><jats:p><jats:bold>Conclusion\u2014<\/jats:bold> PCA using a 3.5\/2.7\u2003mm CLP reduces the need for external coaptation and seemingly reduces postoperative morbidity associated with other internal fixation techniques.<\/jats:p><jats:p><jats:bold>Clinical Relevance\u2014<\/jats:bold> PCA can be performed safely and successfully using a 3.5\/2.7\u2003mm CLP, with low postoperative morbidity compared with other PCA techniques. Particular attention should be taken when applying the distal component of the plate.<\/jats:p>","DOI":"10.1111\/j.1532-950x.2009.00573.x","type":"journal-article","created":{"date-parts":[[2009,9,24]],"date-time":"2009-09-24T15:44:22Z","timestamp":1253807062000},"page":"852-860","source":"Crossref","is-referenced-by-count":34,"title":["Clinical Evaluation of Pancarpal Arthrodesis Using a CastLess Plate in 11 Dogs"],"prefix":"10.1111","volume":"38","author":[{"given":"STEPHEN P.","family":"CLARKE","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JOHN F.","family":"FERGUSON","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ANDREW","family":"MILLER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,9,24]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"2170","volume-title":"Textbook of small animal surgery","author":"Lesser AS","year":"2003"},{"key":"e_1_2_6_3_2","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1055\/s-0038-1632985","article-title":"Carpal derangement and associated carpal valgus in a dog","volume":"19","author":"Comerford EJ","year":"2006","journal-title":"Vet Comp Orthop Traumatol"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-0813.1980.tb02600.x"},{"key":"e_1_2_6_5_2","first-page":"35","article-title":"Pancarpal arthrodesis in the dog","volume":"10","author":"Parker RB","year":"1981","journal-title":"a review of forty-five cases"},{"key":"e_1_2_6_6_2","first-page":"177","article-title":"A Radiographic study of the effects of autologous cancellous bone grafts on bone healing after carpal arthrodesis","volume":"22","author":"Johnson KA","year":"1981","journal-title":"Vet Radiol"},{"key":"e_1_2_6_7_2","first-page":"329","article-title":"Partial carpal and pancarpal arthrodesis in the dog","volume":"32","author":"Denny HR","year":"1991","journal-title":"a review of 50 cases"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1053\/jvet.1999.0025"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1632474"},{"key":"e_1_2_6_10_2","first-page":"875","article-title":"Palmer surface plating for arthrodesis in the canine carpus","volume":"18","author":"Chambers JN","year":"1982","journal-title":"J Am Anim Hosp Assoc"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00025.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1136\/vr.107.6.126"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.2003.tb00129.x"},{"key":"e_1_2_6_14_2","first-page":"254","volume-title":"An Atlas of Surgical Approaches To The Bones and Joints of the Dog and Cat","author":"Piermattei DL","year":"2004"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(91)50081-4"},{"key":"e_1_2_6_16_2","first-page":"488","article-title":"Ischemic bandage injuries","volume":"29","author":"Anderson DM","year":"2000","journal-title":"a case series and review of the literature"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2006.00179.x"},{"key":"e_1_2_6_18_2","first-page":"105","article-title":"Treatment of carpometacarpal and middle carpal joint hyperextension injuries with partial carpal arthrodesis using a cross pin technique","volume":"16","author":"Haburjak JJ","year":"2003","journal-title":"21 cases"},{"key":"e_1_2_6_19_2","first-page":"1275","volume-title":"Current Techniques in Small Animal Surgery","author":"Turner TM","year":"1998"},{"key":"e_1_2_6_20_2","first-page":"450","volume-title":"AO Principles of Fracture Management in the Dog and Cat","author":"Johnson AL","year":"2005"},{"key":"e_1_2_6_21_2","first-page":"177","article-title":"An in vitro comparison of a 2.7\/3.5\u2003mm hybrid plate alone and combined with crossed K\u2010wires for canine pancarpal arthrodesis","volume":"21","author":"Arnott JL","year":"2008","journal-title":"Vet Comp Orthop Traumatol"},{"key":"e_1_2_6_22_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1055\/s-0038-1632665","article-title":"Extraction resistance of 2.7\u2003mm medio\u2010lateral placed cortical screws compared with 2.7\u2003mm and 3.5\u2003mm cranio\u2010caudal placed cortical screws in canine cadaver radii","volume":"14","author":"Linn LL","year":"2001","journal-title":"Vet Comp Orthop Traumatol"},{"key":"e_1_2_6_23_2","first-page":"305","article-title":"What is your diagnosis?","volume":"46","author":"Farrell M","year":"2005","journal-title":"J Small Anim Pract"},{"key":"e_1_2_6_24_2","first-page":"33","volume-title":"Manual of Internal Fixation in Small Animals","author":"Prieur WD","year":"1984"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2007.00326.x"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2009.00573.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2009.00573.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T16:03:17Z","timestamp":1697558597000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2009.00573.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9,24]]},"references-count":24,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["10.1111\/j.1532-950X.2009.00573.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2009.00573.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9,24]]}}}