{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T23:38:39Z","timestamp":1776469119172,"version":"3.51.2"},"reference-count":20,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2009,12,8]],"date-time":"2009-12-08T00:00:00Z","timestamp":1260230400000},"content-version":"vor","delay-in-days":7,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:p><jats:bold>Objective\u2014<\/jats:bold>To evaluate the fatigue life of partially stacked and fully stacked (1.5\/2.0 and 2.0\/2.7\u2003mm) veterinary cuttable plates (VCP) in a fracture gap model of the distal aspect of the radius.<\/jats:p><jats:p><jats:bold>Study Design\u2014<\/jats:bold>In vitro biomechanical study.<\/jats:p><jats:p><jats:bold>Methods\u2014<\/jats:bold>Constructs (n=4\/group) were assembled for each of 8 groups using 8\u2010hole plates (1.5\/2.0 and 2.0\/2.7\u2003mm VCP) in the following configurations: unstacked; 2\u2010hole stacked centered over the gap (COG); 4\u2010hole stacked COG; and fully stacked. Plate(s) were secured to 2 separate polyvinylchloride pipe lengths, mounted to a mechanical testing system with a custom jig, and were loaded in axial compression for 10<jats:sup>6<\/jats:sup>cycles at 10\u2003Hz or until failure at 6\u201360\u2003N for the 1.5\/2.0\u2003mm VCP and 10\u2013100\u2003N for the 2.0\/2.7\u2003mm VCP. Differences in number of cycles, stiffness, and failure mode were recorded.<\/jats:p><jats:p><jats:bold>Results\u2014<\/jats:bold>All construct failures occurred through a screw hole adjacent to the gap. Fully stacked and 4\u2010hole stacked 1.5\/2.0 and 2.0\/2.7\u2003mm VCP withstood 10<jats:sup>6<\/jats:sup>cycles. Fatigue life and stiffness of the 1.5\/2.0 or 2.0\/2.7\u2003mm unstacked constructs were significantly less than the other constructs. Differences were identified in stiffness among the 1.5\/2.0\u2003mm stacked constructs and in fatigue life among the 2.0\/2.7\u2003mm VCP stacked constructs.<\/jats:p><jats:p><jats:bold>Conclusion\u2014<\/jats:bold>Four\u2010hole partially stacked VCP (either 1.5\/2.0 or 2.0\/2.7\u2003mm) have comparable mechanical properties to fully stacked VCP.<\/jats:p><jats:p><jats:bold>Clinical Relevance\u2014<\/jats:bold>Partial stacking of 2 holes of VCP on both sides of the fracture gap may provide sufficient strength for healing, but this premise must be tested in vivo.<\/jats:p>","DOI":"10.1111\/j.1532-950x.2009.00587.x","type":"journal-article","created":{"date-parts":[[2009,12,8]],"date-time":"2009-12-08T23:14:05Z","timestamp":1260314045000},"page":"954-960","source":"Crossref","is-referenced-by-count":12,"title":["Biomechanical Analysis of Stacked Plating Techniques to Stabilize Distal Radial Fractures in Small Dogs"],"prefix":"10.1111","volume":"38","author":[{"given":"BRIAN W.","family":"ROSE","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. ELIZABETH","family":"PLUHAR","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ROBERTO E.","family":"NOVO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SCOTT","family":"LUNOS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,12,8]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.1979.tb06679.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.5326\/15473317-35-3-243"},{"key":"e_1_2_6_4_2","first-page":"217","article-title":"Treatment of radius\u2010ulna and tibia fractures with circular external skeletal fixator in 19 dogs","volume":"10","author":"Bilgili H","year":"2007","journal-title":"Pol J Vet Sci"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1632921"},{"key":"e_1_2_6_6_2","first-page":"791","article-title":"Management of a distal metaphyseal radial fracture in a dog with a mini T\u2010plate","volume":"161","author":"Lakshmi ND","year":"2007","journal-title":"Vet Rec"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ctsap.2004.09.005"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(92)50009-2"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00003.x"},{"key":"e_1_2_6_10_2","first-page":"57","article-title":"The intraosseous blood supply of the canine radius","volume":"26","author":"Welch JA","year":"1997","journal-title":"implications for healing of distal fractures in small dogs"},{"key":"e_1_2_6_11_2","first-page":"10","article-title":"Mechanical analysis of the veterinary cuttable plate","volume":"4","author":"Fructer AM","year":"1991","journal-title":"Vet Comp Orthop Traumatol"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(80)80044-1"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2006.00191.x"},{"key":"e_1_2_6_14_2","unstructured":"Mini Fragment System Technique Guide. Synthes Vet 2008."},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200802000-00009"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198305000-00047"},{"key":"e_1_2_6_17_2","doi-asserted-by":"crossref","first-page":"915","DOI":"10.2460\/ajvr.1987.48.06.915","article-title":"Force plate analysis of the walking gait in healthy dogs","volume":"48","author":"Budsberg SC","year":"1987","journal-title":"Am J Vet Res"},{"key":"e_1_2_6_18_2","first-page":"11","article-title":"Evaluation of a canine total\u2010elbow arthroplasty system","volume":"30","author":"Conzemius MG","year":"2001","journal-title":"a preliminary study in normal dogs"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2004.65.1497"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2007.00311.x"},{"key":"e_1_2_6_21_2","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.2460\/ajvr.1993.54.09.1523","article-title":"Effects of subject velocity on force plate\u2010measured ground reaction forces in healthy greyhounds at the trot","volume":"54","author":"Riggs CM","year":"1993","journal-title":"Am J Vet Res"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2009.00587.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2009.00587.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T18:39:33Z","timestamp":1739471973000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2009.00587.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["10.1111\/j.1532-950X.2009.00587.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2009.00587.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}