{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:01:08Z","timestamp":1787014868109,"version":"build-2736575974"},"reference-count":31,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2011,1,18]],"date-time":"2011-01-18T00:00:00Z","timestamp":1295308800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2011,4]]},"abstract":"<jats:p>\n                    <jats:bold>Objective:<\/jats:bold>\n                    To identify a method of composite application for maxillomandibular fixation (MMF) in cats that ensures the material will remain bonded during convalescence but be easy to remove with a low complication rate.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Study Design:<\/jats:bold>\n                    Experimental study\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Sample Population:<\/jats:bold>\n                    Feline cadavers (n=88).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:<\/jats:bold>\n                    MMF was applied using composite to 4 groups of 22 feline cadaver heads each. The protocols were: group CR: acid etch and composite resin; group CR+: acid etch, bonding agent, and composite resin; group FR50: partial surface acid etch and flowable composite resin; group FR100: complete surface acid etch and flowable composite resin. Removal time and complication rate were noted. Load to failure was determined by tensile loading.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    Load to failure was similar for groups CR and CR+ and for groups FR50 and FR100; however, load to failure for groups FR50 and FR100 was higher than groups CR and CR+ (\n                    <jats:italic>P<\/jats:italic>\n                    &lt;.01). Time for material removal for group FR100 was longer (\n                    <jats:italic>P<\/jats:italic>\n                    &lt;.01) and the complication rate was higher (\n                    <jats:italic>P<\/jats:italic>\n                    &lt;.01) compared with the groups CR, CR+, and FR50, with no significant differences in removal times and complication rate between the latter groups. The most frequent complication during material removal in group FR100 was crown fracture.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:<\/jats:bold>\n                    Partial coronal surface acid etch before use of flowable composite maintained a strong bond, yet resulted in easy material removal with a low complication rate.\n                  <\/jats:p>","DOI":"10.1111\/j.1532-950x.2010.00782.x","type":"journal-article","created":{"date-parts":[[2011,1,18]],"date-time":"2011-01-18T16:59:18Z","timestamp":1295369958000},"page":"357-368","source":"Crossref","is-referenced-by-count":19,"title":["Evaluation of Composite Resin Materials for Maxillomandibular Fixation in Cats for Treatment of Jaw Fractures and Temporomandibular Joint Luxations"],"prefix":"10.1111","volume":"40","author":[{"given":"Melissa","family":"Hoffer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Manfra Marretta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kurath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominique","family":"Griffon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Schaeffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald","family":"Pijanowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Przywara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,1,18]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1988.tb01028.x"},{"key":"e_1_2_6_3_2","first-page":"220","article-title":"Problems associated with the management and treatment of jaw fractures","volume":"2","author":"Manfra Marretta S","year":"1990","journal-title":"Probs Vet Med"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1994.tb00471.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cvsm.2005.03.003"},{"key":"e_1_2_6_6_2","first-page":"102","article-title":"Diseases of the temporomandibular joint and associated structures","volume":"12","author":"Robins G","year":"1982","journal-title":"Aust Vet Pract"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/089875640702400312"},{"key":"e_1_2_6_8_2","volume-title":"Veterinary dental techniques for the small animal practitioner","author":"Holmstrom S","year":"2004"},{"key":"e_1_2_6_9_2","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1055\/s-0038-1633078","article-title":"Dental trauma caused by screws in internal fixation of mandibular osteotomies in the dog","volume":"5","author":"Verstraete FM","year":"1992","journal-title":"Vet Comp Orth Traumatol"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.1991.tb00559.x"},{"key":"e_1_2_6_11_2","first-page":"555","article-title":"Treatment of caudal mandibular fractures","volume":"17","author":"Nibley W","year":"1981","journal-title":"a preliminary report"},{"key":"e_1_2_6_12_2","first-page":"16","article-title":"Interarcade wiring","volume":"1","author":"Umphlet R","year":"1987","journal-title":"a method for stabilization of caudal mandibular fractures and temporomandibular joint luxations in the cat"},{"key":"e_1_2_6_13_2","first-page":"5","article-title":"Treatment of jaw fractures in cats with parapulpal pins for composite bridge","volume":"32","author":"Zetner K","year":"1987","journal-title":"Kleintierpraxis"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(92)50138-3"},{"key":"e_1_2_6_15_2","volume-title":"Introduction to dental naterials","author":"Van Noort R","year":"1994"},{"key":"e_1_2_6_16_2","volume-title":"Phillips' science of dental materials","author":"Anusavice K","year":"1996"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345550340060801"},{"key":"e_1_2_6_18_2","unstructured":"MulliganTWThe use of dental acrylics in mandibular fracture repair.Proceedings American Animal Hospital Association Toronto 1991 pp 319\u2013322"},{"key":"e_1_2_6_19_2","volume-title":"Dental biomaterials","author":"Combe E","year":"1999"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1615\/JLongTermEffMedImplants.v15.i6.70"},{"key":"e_1_2_6_21_2","volume-title":"Protemp 3 garant temporization material technical product profile","author":"3M ESPE","year":"2007"},{"key":"e_1_2_6_22_2","first-page":"571","article-title":"Dental biomaterials","volume":"69","author":"Bayne S","year":"2005","journal-title":"where are we and where are we going?"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1177\/089875640402100302"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(95)50108-1"},{"key":"e_1_2_6_25_2","first-page":"284","volume-title":"Geometry for dummies","author":"Ryan M","year":"2008"},{"key":"e_1_2_6_26_2","first-page":"26S","article-title":"The spectrum of composites","volume":"131","author":"Fortin D","year":"2000","journal-title":"new techniques and materials"},{"key":"e_1_2_6_27_2","first-page":"E215","article-title":"Composite resins. A review of the materials and clinical indications","volume":"11","author":"Hervas\u2010Garcia A","year":"2006","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"e_1_2_6_28_2","first-page":"64, 66","article-title":"Liners, bases, and cements","volume":"24","author":"Weiner R","year":"2005","journal-title":"material selection and clinical applications"},{"key":"e_1_2_6_29_2","first-page":"299","article-title":"The microtensile bond test","volume":"1","author":"Pashley D","year":"1999","journal-title":"a review"},{"key":"e_1_2_6_30_2","first-page":"118","article-title":"A critical review of the durability of adhesion to tooth tissue","volume":"84","author":"Demunk J","year":"2005","journal-title":"methods and results"},{"key":"e_1_2_6_31_2","first-page":"17","volume-title":"Module 30 composites. In ME330 behavior of engineering materials","author":"Kurath P","year":"2006"},{"key":"e_1_2_6_32_2","first-page":"2","volume-title":"Basic biomechanics of the musculoskeletal system","author":"Frankel V","year":"2001"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2010.00782.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2010.00782.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T02:08:55Z","timestamp":1698718135000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2010.00782.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,18]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,4]]}},"alternative-id":["10.1111\/j.1532-950X.2010.00782.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2010.00782.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,18]]}}}