{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T03:03:21Z","timestamp":1788491001498,"version":"build-2803163510"},"reference-count":19,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2011,9,16]],"date-time":"2011-09-16T00:00:00Z","timestamp":1316131200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2011,10]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To compare the holding strength of a conventional plate\u2010screw construct with a locking plate\u2010screw construct in the thin cortical bone of the canine mandibular ramus.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study design<\/jats:title><jats:p>Mechanical study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Animals<\/jats:title><jats:p>Paired cadaveric canine mandibles (n = 10 pairs).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Perpendicular pull\u2010out testing was performed on 2.0\u2010mm limited\u2010contact dynamic compression plate (LC\u2010DCP)\u2010screw constructs and 2.0\u2010mm string\u2010of\u2010pearls (SOP) plate\u2010screw constructs applied to the ramus of the canine mandible. Pull\u2010out force was applied perpendicular to the long axis of the plates. Construct stiffness and load at failure were determined from load\u2010displacement curves and method of failure was determined from high speed digital video recordings. A paired t\u2010test was used to compare mean construct stiffness and load at failure between groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>SOP plate\u2010screw constructs had a significantly higher mean construct stiffness and load at failure than did LC\u2010DCP\u2010screw constructs. LC\u2010DCP constructs failed by screw pull\u2010out while bone slicing and fracture were prominent mechanisms of failure for SOP constructs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>SOP plate\u2010screw constructs sustained a significantly higher perpendicular load at failure than did LC\u2010DCP\u2010screw constructs.<\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1532-950x.2011.00893.x","type":"journal-article","created":{"date-parts":[[2011,9,16]],"date-time":"2011-09-16T21:58:24Z","timestamp":1316210304000},"page":"870-874","source":"Crossref","is-referenced-by-count":7,"title":["Perpendicular Pull\u2010Out Force of Locking Versus Non\u2010Locking Plates in Thin Cortical Bone Using a Canine Mandibular Ramus Model"],"prefix":"10.1111","volume":"40","author":[{"given":"Emily I.","family":"Miller","sequence":"first","affiliation":[{"name":"Department of Veterinary Clinical Sciences Dr. W. Eugene and Linda Lloyd Veterinary Medical Center College of Veterinary Medicine Iowa State University  Ames IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony E.","family":"Acquaviva","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences Dr. W. Eugene and Linda Lloyd Veterinary Medical Center College of Veterinary Medicine Iowa State University  Ames IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Eisenmann","sequence":"additional","affiliation":[{"name":"Iowa State University Center for Nondestructive Evaluation  Ames IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard T.","family":"Stone","sequence":"additional","affiliation":[{"name":"Department of Industrial and Manufacturing Systems Engineering Iowa State University  Ames IA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl H.","family":"Kraus","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences Dr. W. Eugene and Linda Lloyd Veterinary Medical Center College of Veterinary Medicine Iowa State University  Ames IA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,9,16]]},"reference":[{"key":"e_1_2_5_2_1","first-page":"2190","volume-title":"Textbook of small animal surgery","author":"Verstraete FJ","year":"2003"},{"key":"e_1_2_5_3_1","first-page":"973","volume-title":"Current techniques in small animal surgery","author":"Dixon BC","year":"1998"},{"key":"e_1_2_5_4_1","first-page":"999","volume-title":"Current techniques in small animal surgery","author":"Willer R","year":"1998"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(95)50108-1"},{"key":"e_1_2_5_6_1","first-page":"717","volume-title":"Brinker, Piermattei, and Flo's handbook of small animal orthopedics and fracture repair","author":"Piermatti D","year":"2006"},{"key":"e_1_2_5_7_1","first-page":"pp 128","volume-title":"Complications in small animal surgery: diagnosis, management, prevention","author":"Lipowitz A","year":"1996"},{"key":"e_1_2_5_8_1","first-page":"1327","article-title":"Plating of canine scapular fractures","volume":"39","author":"Mbogwa S","year":"1978","journal-title":"Am J Vet Res"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.026"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2007.08.009"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2006.09.009"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.01.003"},{"key":"e_1_2_5_13_1","volume-title":"Standard operating procedures for SOP fixation of fractures version 1.4","author":"Kraus KH","year":"2007"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2004.04.001"},{"key":"e_1_2_5_15_1","first-page":"283","article-title":"Holding power of orthopedic screws in bone","volume":"72","author":"Koranyi B","year":"1970","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200303000-00005"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0030-1248022"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200409000-00003"},{"key":"e_1_2_5_19_1","unstructured":"KowaleskiM:Locking plate systems: SOP and ALPS.Proc Spring Scientific Meeting of the British Veterinary Orthopaedic Association Birmingham UK 2009 pp4\u20139"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2007.06.016"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1532-950X.2011.00893.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1532-950X.2011.00893.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T14:39:14Z","timestamp":1700491154000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1532-950X.2011.00893.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9,16]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["10.1111\/j.1532-950X.2011.00893.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1532-950x.2011.00893.x","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9,16]]}}}