{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T07:45:53Z","timestamp":1794469553517,"version":"4.9.1"},"reference-count":19,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2008,3,19]],"date-time":"2008-03-19T00:00:00Z","timestamp":1205884800000},"content-version":"vor","delay-in-days":18,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pain Practice"],"published-print":{"date-parts":[[2008,3]]},"abstract":"<jats:title>\u25aa\u2002Abstract<\/jats:title><jats:p><jats:bold>Background:\u2003<\/jats:bold> Spinal cord stimulation (SCS) is increasingly utilized for inoperable, intractable chest pain because of ischemia. Because patients with ischemic heart disease commonly have permanent cardiac pacemakers (PPM) or automated implantable cardio\u2010defibrillators (AICD), concurrent use of SCS and PPM or AICD may grow. Interference between SCS and PPM or AICD devices is potentially dangerous and has been previously reported.<\/jats:p><jats:p><jats:bold>Case report:\u2003<\/jats:bold> A 51\u2010year\u2010old woman who underwent multiple catheter\u2010based cardiac ablations for a variety of tachy\u2010atrial arrhythmias. These procedures included atrioventricular node destruction, which left her PPM\u2010dependent (third degree heart block with an intrinsic heart rate in the 30s). During the course of her cardiac treatment, she developed chest pain which was not amenable to cardiac intervention and was refractory to medical management. The patient was evaluated for consideration of SCS and ultimately underwent implantation. Procedures evaluating SCS\u2013PPM compatibility were followed and are described. Immediately after SCS implantation and at 6\u2003months follow\u2010up, the patient experienced improved pain relief.<\/jats:p><jats:p><jats:bold>Discussion:\u2003<\/jats:bold> Others have reported SCS implantation in patients with PPM. This is the first report to describe safe and effective use of an Advanced Bionics\u00ae SCS in a patient with a Guidant\u00ae PPM. In addition, we speculate that this patient's cardiac pain may have been other than ischemic in origin. As such, this case may represent a unique clinical scenario. Despite many cases series and case reports demonstrating safety of concurrent SCS and PPM or AICD, the complexity of these technologies requires continued demonstration of device compatibility in novel contexts.\u2002\u25aa<\/jats:p>","DOI":"10.1111\/j.1533-2500.2008.00178.x","type":"journal-article","created":{"date-parts":[[2008,3,19]],"date-time":"2008-03-19T12:02:43Z","timestamp":1205928163000},"page":"110-113","source":"Crossref","is-referenced-by-count":12,"title":["Thoracic Spinal Cord Stimulation for Post\u2010Ablation Cardiac Pain in a Patient with Permanent Pacemaker"],"prefix":"10.1111","volume":"8","author":[{"given":"Bryan C.","family":"Hoelzer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abram H.","family":"Burgher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc A.","family":"Huntoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,3,19]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-196707000-00025"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000166502.05449.a8"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejpain.2004.09.003"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/ejvs.2002.1876"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(98)70171-1"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.05.096"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2003.08.003"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02070.x"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01033.x"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0304-3959(97)00171-1"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00045.x"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00074.x"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(03)00110-3"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2003.00332.x"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1099-5129(03)00086-2"},{"key":"e_1_2_5_17_2","first-page":"249","article-title":"Feasibility of spinal cord stimulation in a patient with a cardiac pacemaker","volume":"9","author":"Kosharskyy B","year":"2006","journal-title":"Pain Physician."},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2006.04.066"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00027.x"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00521.x"}],"container-title":["Pain Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1533-2500.2008.00178.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1533-2500.2008.00178.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T12:07:21Z","timestamp":1697112441000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1533-2500.2008.00178.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2008,3]]}},"alternative-id":["10.1111\/j.1533-2500.2008.00178.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1533-2500.2008.00178.x","archive":["Portico"],"relation":{},"ISSN":["1530-7085","1533-2500"],"issn-type":[{"value":"1530-7085","type":"print"},{"value":"1533-2500","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,3]]}}}