{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T12:17:26Z","timestamp":1778933846304,"version":"3.51.4"},"reference-count":25,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2005,5,3]],"date-time":"2005-05-03T00:00:00Z","timestamp":1115078400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[2005,6]]},"abstract":"<jats:p><jats:bold>BACKGROUND:<\/jats:bold> The major problem with long\u2010term cord blood (CB) banking is the required storage space. In this sense, many studies have been performed to establish techniques for volume reduction of CB units.<\/jats:p><jats:p><jats:bold>STUDY DESIGN AND METHODS:<\/jats:bold> We compared two different methods for CB volume reduction in both development and routine phases: hydroxyethyl starch (HES) sedimentation and top\u2010and\u2010bottom fractionation with the Optipress\u2003II (Baxter Healthcare). Monitoring the total nucleated cell (TNC) count, lymphocytes, CD34+ cells, and colony\u2010forming unit (CFU) content in both preprocess and postprocess CB units assessed the volume reduction process.<\/jats:p><jats:p><jats:bold>RESULTS:<\/jats:bold> The CB units processed in both groups had comparable volume and cells counts before and after volume reduction, except for number of red blood cells (RBCs), which was significantly greater for the Optipress II group. Recoveries of CD34+ and RBC depletion were significantly better for the HES group. For routine processing, TNC and lymphocyte recoveries were significantly better for CB units processed by the Optipress II system. There was, however, significantly less depletion of RBCs for this group. The time required for CB processing with the Optipress II was significantly shorter than the time needed for volume reduction by addition of HES (25\u2003\u00b1\u20035\u2003min vs. 55\u2003\u00b1\u200310\u2003min).<\/jats:p><jats:p><jats:bold>CONCLUSION:<\/jats:bold> The volume reduction method with the Optipress\u2003II is a closed time\u2010saving system that allows good cell recoveries. In contrast, the main advantage of the HES method is the higher RBC depletion that influences CFU content. Reducing RBC content must be the object of further improvements for volume reduction using the Optipress II method.<\/jats:p>","DOI":"10.1111\/j.1537-2995.2005.04357.x","type":"journal-article","created":{"date-parts":[[2005,6,20]],"date-time":"2005-06-20T23:21:15Z","timestamp":1119309675000},"page":"867-873","source":"Crossref","is-referenced-by-count":32,"title":["Red blood cell depletion with a semiautomated system or hydroxyethyl starch sedimentation for routine cord blood banking: a comparative study"],"prefix":"10.1111","volume":"45","author":[{"given":"Pilar","family":"Solves","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vicente","family":"Mirabet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dolores","family":"Planelles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ignacio","family":"Blasco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alfredo","family":"Perales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco","family":"Carbonell\u2010Uberos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. Angeles","family":"Soler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Roig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,5,31]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198910263211707"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-472X(00)00540-3"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.leu.2402688"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2001.00039.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1006\/cryo.1995.1052"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00282-999-0001-2"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.1999.7640237.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-472X(98)00016-2"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2001.41030344.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2003.00276.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bmt.1701591"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1080\/146532400539387"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2003.00398.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2002.00259.x"},{"key":"e_1_2_6_16_2","first-page":"587","article-title":"Unrelated placental blood for bone marrow reconstitution: organization of the placental blood program","volume":"20","author":"Rubinstein P","year":"1994","journal-title":"Blood Cells"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1089\/scd.1.1996.5.213"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2003.00486.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2002-01-0294"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1182\/blood.V96.8.2717"},{"key":"e_1_2_6_21_2","first-page":"390","article-title":"Quality analysis of blood components obtained by automated buffy\u2010coat layer removal with top & bottom system (Optipress II)","volume":"85","author":"Hurtado C","year":"2000","journal-title":"Haematologica"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bmt.1701881"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2141.2004.04923.x"},{"key":"e_1_2_6_24_2","first-page":"S14","article-title":"Volume reduction of cord blood by hetastarch for long\u2010term stem cell banking","volume":"22","author":"Kogler G","year":"1998","journal-title":"Bone Marrow Transplant"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1089\/152581601317210890"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2002.00133.x"}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1537-2995.2005.04357.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1537-2995.2005.04357.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T11:58:11Z","timestamp":1695902291000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1537-2995.2005.04357.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,5,31]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["10.1111\/j.1537-2995.2005.04357.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1537-2995.2005.04357.x","archive":["Portico"],"relation":{},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,5,31]]}}}