{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T23:44:55Z","timestamp":1792107895754,"version":"4.4.0"},"reference-count":28,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2007,5,2]],"date-time":"2007-05-02T00:00:00Z","timestamp":1178064000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[2007,7]]},"abstract":"<jats:p><jats:bold>BACKGROUND:<\/jats:bold> Compatibility testing is the standard protocol that identifies suitable blood for patients requiring transfusion. If the antibody screen is negative or no clinically significant antibodies are detected, BCSH guidelines and AABB standards allow an immediate\u2010spin crossmatch (IS XM) or even electronic issue. The testing requirement is less clear where autoantibodies or non\u2013clinically significant alloantibodies compromise the indirect antiglobulin test crossmatch (IAT XM). Performing an IAT XM will give a mismatched result anyway, delays the supply of blood to the patient, and provides no additional benefit or safety.<\/jats:p><jats:p><jats:bold>STUDY DESIGN AND METHODS:<\/jats:bold> From January 2002 to April 2006, the provision of blood for autoimmune hemolytic anemia (AIHA) patients with autoantibodies and no alloantibodies as well as patients with alloantibodies that exhibited a \u201chigh\u2010titer, low\u2010avidity\u201d (HTLA) mode of reactivity was reviewed.<\/jats:p><jats:p><jats:bold>RESULTS:<\/jats:bold> A total of 222 AIHA patients (428 samples) with autoantibodies had 1585\u2003units of red cells supplied after IAT XM; 1308 (82.5%) were mismatched. In 50 patients (80 samples) with HTLA\u2010like antibodies, 286\u2003units of 328 (87.2%) were mismatched by IAT XM.<\/jats:p><jats:p><jats:bold>CONCLUSION:<\/jats:bold> No adverse reactions were reported for the study groups where \u201csuitable\u201d blood was provided after a serologically mismatched IAT XM. No additional benefit for these patients can be claimed by performing an IAT XM over an IS XM, as a check of ABO match. The IAT XM is both costly and time\u2010consuming. It is proposed that for these study group patients, a reduction to an IS XM can be applied and can be beneficial.<\/jats:p>","DOI":"10.1111\/j.1537-2995.2007.01272.x","type":"journal-article","created":{"date-parts":[[2007,5,9]],"date-time":"2007-05-09T01:39:46Z","timestamp":1178674786000},"page":"1290-1295","source":"Crossref","is-referenced-by-count":6,"title":["Do patients with autoantibodies or clinically insignificant alloantibodies require an indirect antiglobulin test crossmatch?"],"prefix":"10.1111","volume":"47","author":[{"given":"Edmond","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Redman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gordon","family":"Burgess","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nay","family":"Win","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,5,2]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1999.39199116888.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.21307\/immunohematology-2019-404"},{"key":"e_1_2_6_4_2","first-page":"28","article-title":"High\u2010titre, low\u2010avidity (HTLA) antibodies and antigens: a review","volume":"11","author":"Rolih SD","year":"1989","journal-title":"Transfus Med Rev"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.1988.tb03893.x"},{"key":"e_1_2_6_6_2","volume-title":"Methods in immunohematology","author":"Judd J","year":"1994"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/78.2.161"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1981.21682085750.x"},{"key":"e_1_2_6_9_2","first-page":"134","article-title":"Development in pertransfusion testing and compatibility testing","volume":"40","author":"Oberman HA","year":"2000","journal-title":"Transfusion"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1997.37597293889.x"},{"key":"e_1_2_6_11_2","first-page":"63","article-title":"The type and screen: a safe alternative and supplement in selected surgical procedures","volume":"7","author":"Boral LI","year":"1977","journal-title":"Transfusion"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03015236"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1979.19680104105.x"},{"key":"e_1_2_6_14_2","volume-title":"Standards for blood banks and transfusion services.","year":"1984"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0958-7578.2004.00482.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-3148.2002.00399.x"},{"key":"e_1_2_6_17_2","volume-title":"Standards for blood banks and transfusion services.","year":"2005"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1999.39199116889.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2000.78302003.x"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1982.22182154207.x"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1978.18278160574.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/86.4.511"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1988.28488265261.x"},{"key":"e_1_2_6_24_2","volume-title":"Standards for blood banks and transfusion services.","year":"1993"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1994.34294143935.x"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.1998.tb05450.x"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-3148.2000.00274.x"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.53.9.673"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2000.7820113.x"}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1537-2995.2007.01272.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1537-2995.2007.01272.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T00:33:26Z","timestamp":1695947606000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1537-2995.2007.01272.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,5,2]]},"references-count":28,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2007,7]]}},"alternative-id":["10.1111\/j.1537-2995.2007.01272.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1537-2995.2007.01272.x","archive":["Portico"],"relation":{},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,5,2]]}}}