{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T02:08:51Z","timestamp":1789697331058,"version":"4.0.1"},"reference-count":18,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2009,4,28]],"date-time":"2009-04-28T00:00:00Z","timestamp":1240876800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[2009,8]]},"abstract":"<jats:p><jats:bold>BACKGROUND:<\/jats:bold> Massive transfusion of D\u2212 trauma patients in the combat setting involves the use of D+ red blood cells (RBCs) or whole blood along with suboptimal pretransfusion test result documentation. This presents challenges to the transfusion service of tertiary care military hospitals who ultimately receive these casualties because initial D typing results may only reflect the transfused RBCs. After patients are stabilized, mixed\u2010field reaction results on D typing indicate the patient's true inherited D phenotype. This case series illustrates the utility of automated gel column agglutination in detecting mixed\u2010field reactions in these patients.<\/jats:p><jats:p><jats:bold>STUDY DESIGN AND METHODS:<\/jats:bold> The transfusion service test results, including the automated gel column agglutination D typing results, of four massively transfused D\u2212 patients transfused D+ RBCs is presented. To test the sensitivity of the automated gel column agglutination method in detecting mixed\u2010field agglutination reactions, a comparative analysis of three automated technologies using predetermined mixtures of D+ and D\u2212 RBCs is also presented.<\/jats:p><jats:p><jats:bold>RESULTS:<\/jats:bold> The automated gel column agglutination method detected mixed\u2010field agglutination in D typing in all four patients and in the three prepared control specimens. The automated microwell tube method identified one of the three prepared control specimens as indeterminate, which was subsequently manually confirmed as a mixed\u2010field reaction. The automated solid\u2010phase method was unable to detect any mixed fields.<\/jats:p><jats:p><jats:bold>CONCLUSION:<\/jats:bold> The automated gel column agglutination method provides a sensitive means for detecting mixed\u2010field agglutination reactions in the determination of the true inherited D phenotype of combat casualties transfused massive amounts of D+ RBCs.<\/jats:p>","DOI":"10.1111\/j.1537-2995.2009.02194.x","type":"journal-article","created":{"date-parts":[[2009,4,28]],"date-time":"2009-04-28T15:21:12Z","timestamp":1240932072000},"page":"1672-1677","source":"Crossref","is-referenced-by-count":4,"title":["The value of automated gel column agglutination technology in the identification of true inherited D blood types in massively transfused patients"],"prefix":"10.1111","volume":"49","author":[{"given":"Thomas","family":"Summers Jr","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viviana V.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John P.","family":"Stephan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gloria J.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Leonard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,7,30]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00062752-200111000-00014"},{"key":"e_1_2_7_3_2","doi-asserted-by":"crossref","first-page":"984","DOI":"10.5858\/2005-129-984-NAPTPR","article-title":"North American pretransfusion testing practices, 2001\u20102004: results from the College of American Pathologists interlaboratory comparison program survey data, 2001\u20102004","volume":"129","author":"Shulman IA","year":"2005","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_2_7_4_2","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1093\/labmed\/28.4.258","article-title":"New technologies in transfusion medicine","volume":"28","author":"Walker PS","year":"1997","journal-title":"Lab Med"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1985.25185116495.x"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1990.30290162895.x"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/82.6.719"},{"key":"e_1_2_7_8_2","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1093\/labmed\/16.12.766","article-title":"Solid phase adherence assays: alternatives to conventional blood bank tests","volume":"16","author":"Rolih SD","year":"1985","journal-title":"Lab Med"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0887-7963(92)70153-9"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1990.30290162894.x"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1998.381098440861.x"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/labmed\/25.2.81"},{"key":"e_1_2_7_13_2","first-page":"S311","article-title":"Use of the gel test to follow up chimerism in ABO mismatched bone marrow","volume":"88","author":"Lumkul R","year":"2005","journal-title":"J Med Assoc Thai"},{"key":"e_1_2_7_14_2","doi-asserted-by":"crossref","first-page":"63","DOI":"10.21307\/immunohematology-2019-662","article-title":"Comparison of tube and gel red blood cell agglutination techniques in detecting chimeras after major ABO\u2010mismatched allogeneic hematopoietic stem cell transplantation","volume":"14","author":"Kupferman MJ","year":"1998","journal-title":"Immunohematology"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2005.04304.x"},{"key":"e_1_2_7_16_2","first-page":"129","article-title":"Comparative study of blood cross matching using conventional tube and gel method","volume":"64","author":"Swarup D","year":"2008","journal-title":"MJAFI"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-3148.2006.00693_52.x"},{"key":"e_1_2_7_18_2","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1093\/ajcp\/71.3.286","article-title":"Quality assurance in the blood bank: studies of technologist performance","volume":"71","author":"Greendyke RM","year":"1979","journal-title":"Am J Clin Pathol"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1978.18478251234.x"}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1537-2995.2009.02194.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1537-2995.2009.02194.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T01:36:30Z","timestamp":1697247390000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1537-2995.2009.02194.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7,30]]},"references-count":18,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2009,8]]}},"alternative-id":["10.1111\/j.1537-2995.2009.02194.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1537-2995.2009.02194.x","archive":["Portico"],"relation":{},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,7,30]]}}}