{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T19:19:29Z","timestamp":1793474369793,"version":"4.5.0"},"reference-count":26,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2011,5,20]],"date-time":"2011-05-20T00:00:00Z","timestamp":1305849600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[2011,11]]},"abstract":"<jats:p>\n                    <jats:bold>BACKGROUND:<\/jats:bold>\n                    The blood product administration process has been subject to various quality improvement initiatives aimed at reducing errors, including blood product labels that are missing, inaccessible, unreadable, or mismatched to orders and\/or patients. This article reports the results of a formal simulation\u2010based usability test of two comparable technologies designed to reduce blood product administration errors.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>STUDY DESIGN AND METHODS:<\/jats:bold>\n                    Nineteen nurses and three anesthesia providers evaluated one of the two products during simulated use in realistic scenarios during 90\u2010minute test sessions. Both products required additional learning despite 15 minutes of dedicated vendor\u2010provided pretest training.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>RESULTS:<\/jats:bold>\n                    There were significant effectiveness differences between the two products, but use of both devices was less efficient than manual checking. Usability issues included poor access to subtasks, lack of process feedback, inadequate error messaging, and confusing device interactions.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>CONCLUSION:<\/jats:bold>\n                    While clinicians' subjective ratings of both devices were similarly high, both products had significant usability issues likely to lead to clinician frustration and workarounds during actual use. This study suggests that usability testing is a valuable and more effective method than preference surveys of determining the ability of blood administration products to meet clinicians' needs in the complex world of patient care.\n                  <\/jats:p>","DOI":"10.1111\/j.1537-2995.2011.03185.x","type":"journal-article","created":{"date-parts":[[2011,5,20]],"date-time":"2011-05-20T12:58:38Z","timestamp":1305896318000},"page":"2311-2318","source":"Crossref","is-referenced-by-count":14,"title":["Blood product positive patient identification: comparative simulation\u2010based usability test of two commercial products"],"prefix":"10.1111","volume":"51","author":[{"given":"Shilo","family":"Anders","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Miller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peggy","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiercy","family":"Fortenberry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcella","family":"Woods","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ray","family":"Booker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Slaughter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew B.","family":"Weinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"France","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,5,20]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199902113400606"},{"key":"e_1_2_8_3_2","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2008-07-077370"},{"key":"e_1_2_8_4_2","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.5858\/2006-130-1662-PSITCL","article-title":"Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors","volume":"130","author":"Wagar EA","year":"2006","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0887-7963(03)00017-8"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1997.37111298088047.x"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-009-9180-0"},{"key":"e_1_2_8_8_2","doi-asserted-by":"crossref","first-page":"563","DOI":"10.5858\/1999-123-0563-EITM","article-title":"Errors in transfusion medicine: scope of the problem","volume":"123","author":"Linden JV","year":"1998","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_2_8_9_2","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.5858\/2009-0674-CP.1","article-title":"Blood bank safety practices: mislabeled samples and wrong blood in tube\u2014a Q\u2010probes analysis of 122 clinical laboratories","volume":"134","author":"Grimm E","year":"2010","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_2_8_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.tmrv.2006.08.007"},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.2008.01049.x"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2006.00729.x"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2008.01668.x"},{"key":"e_1_2_8_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccell.2010.03.002"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.moh.0000142801.38087.e5"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1309\/QNR1B7310H7376MP"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-144-7-200604040-00010"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1197\/jamia.M1061"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1518\/001872006776412234"},{"key":"e_1_2_8_20_2","unstructured":"International Organization for Standardization.ISO9241:11 Ergonomic requirements for office work with visual display terminals (VDTs)\u2014Guidance on usability.1998. Geneva: International Organization for Standardization."},{"key":"e_1_2_8_21_2","unstructured":"Association for the Advancement of Medical Instrumentation.ANSI\/AAMI HE75: human factors engineering\u2014design of medical devices.2009. Arlington VA: Association for the Advancement of Medical Instrumentation."},{"key":"e_1_2_8_22_2","volume-title":"Interaction design: beyond human\u2010computer interaction","author":"Preece J","year":"2007"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1145\/259963.260531"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.2307\/3150446"},{"key":"e_1_2_8_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00302458"},{"key":"e_1_2_8_26_2","volume-title":"About face 3: the essentials of interaction design","author":"Cooper A","year":"2007"},{"key":"e_1_2_8_27_2","volume-title":"Handbook of human factors in medical device design","author":"Weinger MB","year":"2011"}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1537-2995.2011.03185.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1537-2995.2011.03185.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T12:02:48Z","timestamp":1697284968000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1537-2995.2011.03185.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,20]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2011,11]]}},"alternative-id":["10.1111\/j.1537-2995.2011.03185.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1537-2995.2011.03185.x","archive":["Portico"],"relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.13762956.15184056","asserted-by":"object"}]},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,20]]}}}