{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T09:57:36Z","timestamp":1777543056629,"version":"3.51.4"},"reference-count":22,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":8703,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1982,9]]},"abstract":"<jats:p>Recent developments in pacemaker technology led us to report our initial and follow\u2010up assessment of atrioventricular (A\u2010V) sequential systems in 50 consecutive patients. Primary indications for pacing were sinus node dysfunction or A\u2010V block. Leads were introduced through the subclavian vein. Atrial J\u2010tined leads (27 silicone, 19 urethane) were positioned in the atrial appendage or stump in 46 patients, and coronary sinus or Bisping leads were placed in 4 patients; all 50 patients had tined ventricular leads. A Medtroric 5992 generator was placed in 35 patients and an Intermedics 259\u201301 generator in 15. Median implantation time was 105 minutes. Complications requiring reoperdtion in 409 patient\u2010nnonths of follow\u2010up included lead retraction (one patient), phrenic nerve stimulation (one), pseudofracture (one), and atrial lead\u2010induced \u201ccross talk\u201d (one). Monthly telephone transmission confirmed atrial capture in 35 patients and loss of capturein 1; the remainder had no identifiable P wave. Ventricular capture was confirmed in all. Postimplant and follow\u2010up checks showed good stability of lead positions. We conch de that these systems have a low incidence of problems in short\u2010term followup. (PACE, Vol. 5, September\u2010October, 1982)<\/jats:p>","DOI":"10.1111\/j.1540-8159.1982.tb02307.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T04:53:04Z","timestamp":1151815984000},"page":"694-699","source":"Crossref","is-referenced-by-count":7,"title":["Early Follow\u2010Up of Lead Performance in Atrioventricular Sequential Systems"],"prefix":"10.1111","volume":"5","author":[{"given":"RICK A.","family":"NISHIMURA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"RONALD E.","family":"VLIETSTRA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JAMES D.","family":"MALONEY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOHN","family":"MERIDETH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1152\/ajplegacy.1911.29.1.32","article-title":"Auricular systole and its relation to ventricular output","volume":"29","author":"Gesell R.A.","year":"1911","journal-title":"Am J. Pbysiol"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1980.tb05247.x"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(66)90154-2"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197003122821101"},{"key":"e_1_2_1_6_2","first-page":"888","article-title":"A critical look at temporary ventricular pacing following cardiac surgery","volume":"82","author":"Curtis J.J.","year":"1977","journal-title":"Surgery"},{"key":"e_1_2_1_7_2","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/S0022-5223(19)39776-4","article-title":"Surgical experience with emporary or permanent A\u2010V sequential demand pacing","volume":"66","author":"Fields J.","year":"1973","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"3","key":"e_1_2_1_8_2","article-title":"Bifocal demand pacemaker","volume":"39","author":"Berkovits B.V.","year":"1969","journal-title":"Circulation"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.63.5.783"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.40.6.589"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.42.5.595"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.73.2.193"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.57.1.103"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.57.1.98"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1980.tb05251.x"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1979.tb05197.x"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)61638-4"},{"key":"e_1_2_1_18_2","first-page":"309","article-title":"Permanent transvenous pacemaker implantation via the subclavian vein","volume":"55","author":"Miller F.A.","year":"1980","journal-title":"Mayo Clin. Proc"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(77)90013-3"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1978.tb03435.x"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-70-5-885"},{"issue":"3","key":"e_1_2_1_22_2","first-page":"58","article-title":"Oxygen cost of atrial and ventricular pacing in the intact conscious dog","volume":"42","author":"Sharma G.V.R.K.","year":"1970","journal-title":"Circulation"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1980.tb05248.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1982.tb02307.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1982.tb02307.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T15:55:15Z","timestamp":1698854115000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1982.tb02307.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1982,9]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1982,9]]}},"alternative-id":["10.1111\/j.1540-8159.1982.tb02307.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1982.tb02307.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1982,9]]}}}