{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T05:21:52Z","timestamp":1698124912653},"reference-count":15,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":5904,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1990,5]]},"abstract":"<jats:p>Two types of pacing leads with different insulation material, polyurethane, and polyethylene, were followed for 44 months with respect to their electrophysiological characteristics and complications. In 48 patients, 32 polyurethane leads (Lifeline 493\u201303) and 16 polyethylene leads (EMT 588 D) were implanted and connected in all cases to the same type of programmable ventricular inhibited (VVI) pulse generator (Programalith, Pacesetter). There was a significant fall during the follow\u2010up in lead impedance with the polyurethane leads (495 \u00b1 62 to 444 \u00b1 58 ohms, P &lt; 0.01), whereas the corresponding measurements for the polyethylene leads were essentially unchanged (360 \u00b1 58 to 378 \u00b1 71 ohm, ns). The energy of the stimulation threshold tended to increase in the polyurethane group, whereas an opposite tendency was observed in the polyethylene group. Pacing and\/or lead failures were not observed in any case. The observed fall in impedance with the polyurethane leads was seemingly of no clinical significance.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1990.tb02072.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T12:27:05Z","timestamp":1151843225000},"page":"583-587","source":"Crossref","is-referenced-by-count":0,"title":["Long\u2010Term Comparison of the Electrical Characteristics of Polyurethane and Polyethylene Insulated Ventricular Leads"],"prefix":"10.1111","volume":"13","author":[{"given":"G\u00d6STA","family":"BLUHM","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FLEMMING F.","family":"LARSEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ROLF","family":"NORDLANDER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. KENNETH","family":"PEHRSSON","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-72367-4_45"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04389.x"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb06688.x"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04388.x"},{"key":"e_1_2_1_6_2","volume-title":"In vivo degradation of a polyurethane","author":"Parins DJ","year":"1981"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04390.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb06687.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1978.tb03436.x"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1984.tb04923.x"},{"key":"e_1_2_1_11_2","first-page":"256","article-title":"Polyurethane cardiac pacing leads\u2014six years experience","volume":"6","author":"Davis M","year":"1984","journal-title":"Eur Rev Biomed Tech"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb05427.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb05408.x"},{"key":"e_1_2_1_14_2","first-page":"122","article-title":"Factors influencing survival of patients with permanent cardiac pacemakers","volume":"185","author":"Nolan SP","year":"1977","journal-title":"Am Surg"},{"key":"e_1_2_1_15_2","first-page":"189","volume-title":"The Artificial Cardiac Pacemaker","author":"Thalen HJT","year":"1969"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(71)90032-1"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1990.tb02072.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1990.tb02072.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T07:44:03Z","timestamp":1698047043000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1990.tb02072.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1990,5]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1990,5]]}},"alternative-id":["10.1111\/j.1540-8159.1990.tb02072.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1990.tb02072.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1990,5]]}}}