{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T17:30:39Z","timestamp":1770831039173,"version":"3.50.1"},"reference-count":12,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":5843,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1990,7]]},"abstract":"<jats:p>The purpose of this study was to determine the relationship between ventricular excitability and the extrasfimulus (S<jats:sub>2<\/jats:sub>) coupling interval in early diastole in humans. The influence of the electrode configuration during bipolar stimulation was examined. Ventricular strength\u2010interval curves were constructed using an eight beat drive train at a cycle length of 600 msec, 2\u2010msec decrements in the S<jats:sub>2<\/jats:sub> coupling interval, and 0.2\u2010mA increments in the current intensity of S<jats:sub>2<\/jats:sub> at each coupling interval. A transient dip in the excitation threshold was observed in early diastole during bipolar pacing when the distal electrode was the anode in six of 17 patients (35%). In contrast, this type of dip was not observed when the distal electrode was the cathode. The excitation threshold at the trough of the dip ranged from 1.0 to 2.2 mA. Unipolar strength\u2010interval curves indicated that a dip occurred with anodal but not cathodal pacing. We postulated that the dip might interfere with the accurate determination of the ventricular effective refractory period by resulting in transient loss of ventricular capture during decremental scanning of diastole with S<jats:sub>2<\/jats:sub>. A gap in ventricular capture was produced in all six patients who demonstrated a dip in the bipolar strength\u2010interval curve by selecting an S<jats:sub>2<\/jats:sub> current intensity that fell within the dip. In conclusion, the bipolar strength\u2010interval curve may display an early diastolic dip in the excitation threshold, depending on the electrode configuration. During determination of the ventricular effective refractory period, if the stimulus intensity falls within the range of current intensities encompassed by the dip, a transient early diastolic gap in ventricular capture will be observed as diastole is scanned with S<jats:sub>2<\/jats:sub>. If this type of gap is not recognized, the ventricular effective refractory period may be overestimated.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1990.tb02124.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T12:34:52Z","timestamp":1151843692000},"page":"875-881","source":"Crossref","is-referenced-by-count":3,"title":["The Ventricular Excitability\u2010Interval Relationship in Early Diastole in Humans: The Influence of the Electrode Configuration During Bipolar Stimulation"],"prefix":"10.1111","volume":"13","author":[{"given":"LAURI K.","family":"TOIVONEN","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALAN H.","family":"KADISH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"WILLIAM H.","family":"KOU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FRED","family":"MORADY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1152\/ajplegacy.1950.163.2.272","article-title":"Excitability of the mammalian ventricle throughout the cardiac cycle","volume":"163","author":"Orias O","year":"1950","journal-title":"Am J Physiol"},{"key":"e_1_2_1_3_2","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1152\/ajplegacy.1951.167.1.88","article-title":"Vulnerability to fibrillation and the ventricular\u2010excitability curve","volume":"167","author":"Hoffman BF","year":"1951","journal-title":"Am J Physiol"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(81)90393-3"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.4.2.196"},{"key":"e_1_2_1_6_2","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1152\/ajplegacy.1957.190.2.383","article-title":"Anodal excitation of cardiac muscle","volume":"190","author":"Cranefield PF","year":"1957","journal-title":"Am J Physiol"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-0736(77)80026-5"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.41.4.468"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(86)90839-8"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.41.2.159"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(85)80259-X"},{"key":"e_1_2_1_12_2","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1152\/ajplegacy.1969.217.4.1236","article-title":"Membrane excitability of the frog ventricle examined by long pulses","volume":"217","author":"Goto M.","year":"1969","journal-title":"Am J Physiol"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.27.5.811"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1990.tb02124.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1990.tb02124.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,22]],"date-time":"2023-10-22T21:03:07Z","timestamp":1698008587000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1990.tb02124.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1990,7]]},"references-count":12,"journal-issue":{"issue":"7","published-print":{"date-parts":[[1990,7]]}},"alternative-id":["10.1111\/j.1540-8159.1990.tb02124.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1990.tb02124.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1990,7]]}}}