{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T17:43:59Z","timestamp":1771263839723,"version":"3.50.1"},"reference-count":19,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":5263,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1992,2]]},"abstract":"<jats:p>Ten patients underwent implantation of a rate adaptive ventricular pacing system with a new pulse generator and lead. The unipolar lead has a steroid eluting tip and a pressure sensor. The first derivative of the signal from this sensor, dP\/dt, is determined and the pacemaker rate is varied in response to changes in the right ventricular dP\/dt<jats:sub>MAx<\/jats:sub>. During implantation, dP\/dt values were in the range of 180\u2013720 mm Hg\/sec, The autothreshold for pacing at 2.5 V remained unchanged 1 month after implantation (0.065 \u00b1 0.045 msec, range 0.05\u20132.00 msec) and only slightly increased after 3 months (0.075 \u00b1 0.045 msec, range 0.05\u20132.00 msec). A significant correlation existed between the dP\/dt measured during implantation and the right ventricular pressure measured by telemetry at follow\u2010up visits (r = 0.93, P = 0.0001). Initial pacemaker programming was performed on the second day after implantation following a short walk and was adjusted subsequent to follow\u2010up visits according to the patient's subjective assessment and in accordance with the results of exercise tests and Holter monitoring. Exercise and Holter tests did not significantly change initial programming. There was a significant correlation between right ventricular systolic pressure and the rate response setting (r = \u2010 0.66, P &lt; 0.05). During dP\/dt pacing, all patients felt well, and eight of these reported an improvement compared to non rate adaptive pacing. The heart rate response to effort and recovery was appropriate. It was concluded that: (1) right ventricular dP\/dt is a suitable parameter for controlling the pacing rate; (2) appropriate programming of the dP\/dt pacemaker results in a suitable heart rate response to exercise and recovery.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1992.tb03065.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T13:41:55Z","timestamp":1151847715000},"page":"211-218","source":"Crossref","is-referenced-by-count":19,"title":["First Derivative of Right Ventricular Pressure, dP\/dt, as a Sensor for a Rate Adaptive VVI Pacemaker: Initial Experience"],"prefix":"10.1111","volume":"15","author":[{"given":"ILYA","family":"OVSYSHCHER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"VICTOR","family":"GUETTA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHAVA","family":"BONDY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"AVI","family":"PORATH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01882.x"},{"key":"e_1_2_1_3_2","first-page":"97","volume-title":"Heart Disease","author":"Personnel V","year":"1989"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1172\/JCI104469"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.53.2.293"},{"key":"e_1_2_1_6_2","first-page":"359","article-title":"Inotropic changes in the left ventricle. The effect of changes in heart rate, aortic pressure and end\u2010diastolic pressure","volume":"211","author":"Furnival CM","year":"1970","journal-title":"J Appl Physiol"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.ph.34.030172.000403"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb06021.x"},{"key":"e_1_2_1_9_2","first-page":"1228","article-title":"The effects of ventricular pacing on right ventricular maximum positive dP\/dt: Implications for a rate\u2010responsive pacing system based on this parameter","volume":"10","author":"Sharma AD","year":"1987","journal-title":"PACE"},{"key":"e_1_2_1_10_2","first-page":"1230","article-title":"Right atrial pressure, right ventricular pressure and dP\/dt: New parameters for regulation rate response in pacemaker","volume":"10","author":"Stangl K","year":"1987","journal-title":"PACE"},{"key":"e_1_2_1_11_2","first-page":"1230","article-title":"First\u2010derivative of right ventricular pressure as a sensor for an implantable rate responsive VVI pacemaker","volume":"10","author":"Sutton R","year":"1987","journal-title":"PACE"},{"key":"e_1_2_1_12_2","first-page":"393","article-title":"Rate responsive pacing used dynamic right ventricular pressure in heart blocked dogs","volume":"5","author":"Bennett TD","year":"1985","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_13_2","first-page":"577","volume-title":"Cardiac Pacing","author":"Bennett TD","year":"1985"},{"key":"e_1_2_1_14_2","first-page":"3A","article-title":"Physiologic pacing based on beat\u2010to\u2010beat measurement of right ventricular dP\/dtMAx: Initial feasibility studies in man","volume":"7","author":"Sharma A","year":"1986","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_15_2","first-page":"515","article-title":"Initial experience with a new rate responsive pacemaker","volume":"13","author":"Ovsyshcher J","year":"1990","journal-title":"PACE"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960130809"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06886.x"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(70)90136-5"},{"key":"e_1_2_1_19_2","first-page":"509","article-title":"He\u2010modynamic response to postural changes in patients with VVI versus DDD pacing","volume":"13","author":"Guetta V","year":"1990","journal-title":"PACE"},{"key":"e_1_2_1_20_2","first-page":"733","article-title":"Postural hemodynamic changes during ventricular pacing: Potential prediction of VVI mode intolerance","volume":"14","author":"Ovsyshcher I","year":"1991","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1992.tb03065.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1992.tb03065.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T15:41:31Z","timestamp":1698075691000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1992.tb03065.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,2]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1992,2]]}},"alternative-id":["10.1111\/j.1540-8159.1992.tb03065.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1992.tb03065.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1992,2]]}}}