{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T13:15:45Z","timestamp":1756991745012},"reference-count":10,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":4959,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1992,12]]},"abstract":"<jats:p>An accelerometer\u2010based rate adaptive generator (EXCEL(tm) VR) has been introduced. A preclinical group of 22 subjects with strap\u2010on devices was observed and reported. A clinical protocol including observation of rate adaptive response to typical daily activities and incremental exercise on a treadmill was administered in seven implanted patients. Indications for implantation in these patients was either second\u2010 or third\u2010degree atrioventricular block (five patients, VVIR pacing mode) and sick sinus syndrome (two patients, AAIR pacing mode). Mean pacing rates were 50 ppm (supine), 56 ppm (standing), 77 ppm (descending the stairs), 81 ppm (slow walk), 83 ppm (slow stair climb), 91 ppm (fast walk), and 92 ppm (fast stair climb). When the arm proximal to the pulse generator was exercised, the rate rose to 92 ppm. When the distal arm was strained, the rate was 63 ppm. During treadmill testing, rates between 82 ppm (2 km\/hour) and 104 ppm (5 km\/hour) were observed. This accelerometer\u2010based rate adaptive pulse generator provided a proportional response to graded activities of treadmill exercise and daily living in these groups of preclinical and clinical subjects.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1992.tb04167.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T13:34:57Z","timestamp":1151847297000},"page":"2245-2249","source":"Crossref","is-referenced-by-count":5,"title":["New Concept in Activity\u2010Controlled Pacemakers: Clinical Results With an Accelerometer\u2010Based Rate Adaptive Pacing System"],"prefix":"10.1111","volume":"15","author":[{"given":"EVA","family":"ERDELITSCH\u2010REISER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HEINER","family":"LANGENFELD","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JAY","family":"MILLERHAGEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KURT","family":"KOCHSIEK","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"108","volume-title":"Physiologie, Technologie, klinische Ergebnisse","author":"Stangl K","year":"1990"},{"key":"e_1_2_1_3_2","first-page":"68","article-title":"Frequenzver\u2010halten des Schrittmachers Activitrax\u2014eine Probandenstudie","volume":"6","author":"Langenfeld H","year":"1986","journal-title":"Herschrittmacher"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb04535.x"},{"key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1111\/pace.1989.12.p1.102","article-title":"Physical movement sensitive pacing: Comparison of two \u201cactivity\u201d\u2010triggered pacing systems","volume":"12","author":"Stangl K","year":"1989","journal-title":"PACE"},{"key":"e_1_2_1_6_2","first-page":"A\u2013110","article-title":"Sensing internal and external body activities","volume":"8","author":"Bunge T","year":"1985","journal-title":"PACE"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01846.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb03992.x"},{"key":"e_1_2_1_9_2","first-page":"1204","article-title":"An accelerometer based adaptive rate pacing system","volume":"13","author":"Millerhagen J","year":"1990","journal-title":"PACE"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1989.tb01549.x"},{"key":"e_1_2_1_11_2","first-page":"1210","article-title":"Distinctive characteristics of EXCELTM VR rate adaptive pacemaker with an innovative activity sensor","volume":"13","author":"Silvermint EH","year":"1990","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1992.tb04167.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1992.tb04167.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T13:50:25Z","timestamp":1698069025000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1992.tb04167.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,12]]},"references-count":10,"journal-issue":{"issue":"12","published-print":{"date-parts":[[1992,12]]}},"alternative-id":["10.1111\/j.1540-8159.1992.tb04167.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1992.tb04167.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1992,12]]}}}