{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:01:48Z","timestamp":1787014908103,"version":"build-2736575974"},"reference-count":11,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":4198,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:p>External defibrillation is widely used for the termination of various atrial and ventricular tachyarrhythmias, including pacemaker patients. Our study was intended to evaluate the effects of DC shocks in 36 patients with unipolar pacemakers implanted in the right pectoral region (25 DDD, 10 VVI, 3 AAI). The shocks were delivered with paddles on the anterior surface of the thorax, as far as possible away from the pacemaker. The pacing output was programmed at 0.5 msec and 5 V (25 patients), 4 V (1 patient), and 2.5 V (10 patients). Transient loss of capture occurred in 18 patients (50%). These patients, compared with those without capture failure, received higher peak and cumulative shock energies, respectively, 216 \u00b1 99 versus 123 \u00b1 50 joules (P &lt; 0.002) and 352 \u00b1 62 versus 147 \u00b1 98 joules (P &lt; 0.004) and had a lower pacemaker pulse amplitude (4.0 \u00b1 1.2 vs 4.6 \u00b1 1.0 V, P = 0.11). Failure to capture lasted from 5 seconds to 30 minutes (mean 157 sec). In 15 patients the ventricular stimulation threshold was measured before and serially after cardioversion. A six\u2010fold threshold increase was observed 3 minutes after the shock (P &lt; 0.004) with gradual recovery to nearly baseline values at 24 hours. Transient sensing failure occurred in 7 of the 17 patients in whom it could be evaluated (41%). Furthermore, three cases of shock induced pacemaker malfunctions were observed requiring replacement of the stimulator in two patients. In conclusion, the incidence of loss of capture in pacemaker patients subjected to electrical cardioversion\/defibrillation is high. The phenomenon is due to an abrupt rise in stimulation threshold, caused by the electrical shock, and may represent a serious hazard in pacemaker dependent patients. The risk of pacing failure could be reduced by utilizing low shock energies when possible, and by programming the pacemaker at its maximal output before cardioversion.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1995.tb02503.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T11:57:30Z","timestamp":1151841450000},"page":"194-198","source":"Crossref","is-referenced-by-count":51,"title":["Transthoracic DC Shock May Represent a Serious Hazard in Pacemaker Dependent Patients"],"prefix":"10.1111","volume":"18","author":[{"given":"GIULIANO","family":"ALTAMURA","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LEOPOLDO","family":"BIANCONI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FRANCESCO","family":"LO BIANCO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"SALVATORE","family":"TOSCANO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FABRIZIO","family":"AMMIRATI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"CLAUDIO","family":"PANDOZI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ANTONIO","family":"CASTRO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MARIO","family":"CARDINALE","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MAURO","family":"MENNUNI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MASSIMO","family":"SANTINI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(69)90073-3"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1979.tb05222.x"},{"key":"e_1_2_1_4_2","first-page":"2571","article-title":"Failure of the pacemaker in electric cardioversion of atrial fibrillation","volume":"154","author":"Nielsen\u2010Kuds JE","year":"1992","journal-title":"Ugeskrift for laeger"},{"key":"e_1_2_1_5_2","first-page":"875","volume-title":"Modern Cardiac Pacing","author":"Levine PA.","year":"1985"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1981.tb06215.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(83)80044-8"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1978.tb03514.x"},{"key":"e_1_2_1_9_2","first-page":"35","volume-title":"Cardiac Pacing: Proceedings of the 6th World Symposium on Cardiac Pacing","author":"Hauser RG","year":"1978"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1981.tb06539.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1981.tb06230.x"},{"key":"e_1_2_1_12_2","first-page":"840","article-title":"Abnormal pacing following defibrillation\u2010exit block after microdislocation of the electrode","volume":"12","author":"Weher M","year":"1980","journal-title":"Z Kardiol"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1995.tb02503.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1995.tb02503.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,26]],"date-time":"2023-10-26T20:31:54Z","timestamp":1698352314000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1995.tb02503.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.1111\/j.1540-8159.1995.tb02503.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1995.tb02503.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,1]]}}}