{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T17:53:44Z","timestamp":1758477224815},"reference-count":27,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":3681,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1996,6]]},"abstract":"<jats:p>Rate adaptive pacing has been shown to improve hemodynamic performance and exercise tolerance during acute testing. However, there remain concerns about its benefit in daily life and possible complications incurred by unnecessary pacing. This double\u2010blind crossover study compared the benefit of rate adaptive (SSIR) versus fixed rate (SSI) pacing under laboratory and daily life conditions in 20 rate incompetent patients with minute ventilation single chamber pacemakers (META II). The heart rate (HR) response during three different exercise tests (treadmill, bicycle ergomctry, walking test) was correlated with the Holler findings during daily life in either pacing mode. The maximal HR was significantly higher in the SSIR\u2010mode compared to the SSI\u2010mode, both during laboratory testing (treadmill: 123 \u00b1 15 vs 93 \u00b1 29 beats\/min: ergometry: 118 \u00b1 15 vs 89 \u00b1 27 beats\/min; walking test: 127 \u00b1 9 vs 95 \u00b1 26 beats\/min, all P values &lt; 0.01) as well as during daily life (Holter: 126 \u00b1 13 vs 103 \u00b1 24 beats\/min, P &lt; 0.01). On Holter, the average HR (71 \u00b1 14 vs 71 \u00b1 8 beats\/min) and the percentage of paced rhythm (54 % vs 62%, SSI\u2010 vs SSIR\u2010mode, P = NS) were not different in either mode. However, despite a 30% rate gain in the SSIR\u2010mode, the exercise capacity remained unchanged, and only 38% of patients preferred the SSIR\u2010mode. Minute ventilation pacemakers provide a physiological rate response to exercise. Irrespective of the protocol used, the findings of laboratory testing are comparable to those during daily life. However, patient selection for rate adaptive single chamber pacing should be made with caution, since the objective benefit of restoring normal chronotropy may subjectively be negligible for most patients.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1996.tb03384.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T17:14:35Z","timestamp":1151860475000},"page":"890-898","source":"Crossref","is-referenced-by-count":7,"title":["Benefits and Limitations of Rate Adaptive Pacing Under Laboratory and Daily Life Conditions in Patients with Minute Ventilation Single Chamber Pacemakers"],"prefix":"10.1111","volume":"19","author":[{"given":"STEFAN","family":"OSSWALD","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTOPH","family":"LEIGGENER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PETER T.","family":"BUSER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MATTHIAS E.","family":"PFISTERER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DIETER","family":"BURCKHARDT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FELIX","family":"BURKART","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.75.1.184"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90143-4"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb05087.x"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1985.tb05723.x"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90052-0"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb02665.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb06321.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(93)90819-U"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1992.tb03112.x"},{"key":"e_1_2_1_11_2","first-page":"269","article-title":"Adjustment of heart rate response of activity\u2010sensing pacemakers by an exercise protocol mimicking daily activities","volume":"3","author":"Osswald S","year":"1993","journal-title":"Eur JCPE"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb04535.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960120907"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb05091.x"},{"key":"e_1_2_1_15_2","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1093\/oxfordjournals.eurheartj.a060291","article-title":"Ventricular rate\u2010adaptive pacing in the elderly","volume":"13","author":"Lau CP","year":"1992","journal-title":"Eur Heart J"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02004.x"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-107-5-714"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.72.5.1037"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06900.x"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(10)80186-X"},{"key":"e_1_2_1_21_2","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1093\/oxfordjournals.eurheartj.a060292","article-title":"Comparison of DDD and \u201cVVI\u2010R like\u201d pacing during moderate exercise: Echo\u2010Doppler study","volume":"13","author":"Lascault G","year":"1992","journal-title":"Eur Heart J"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1987.tb05971.x"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90671-1"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(88)90891-0"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01877.x"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.79.4.845"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(84)90691-X"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb01370.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1996.tb03384.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1996.tb03384.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T07:11:51Z","timestamp":1698390711000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1996.tb03384.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,6]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1996,6]]}},"alternative-id":["10.1111\/j.1540-8159.1996.tb03384.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1996.tb03384.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,6]]}}}