{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T08:03:30Z","timestamp":1770278610015,"version":"3.49.0"},"reference-count":25,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":3833,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1996,1]]},"abstract":"<jats:p>The extraction of chronically implanted and infected pacemaker and defibrillator leads is an important issue. This article describes the experience gathered between 1990 and 1994 by seven European centers regarding a locking stylet that is uniformly applicable for a wide variety of internal pacing coil diameters. This interventional locking stylet for lead extraction has an outer diameter of 0.4 mm (0.016 inches). The stylet consists of a hollow shaft in which an inner traction wire is embedded. At the tip of the inner traction wire an anchoring mechanism, which can be opened by retraction, is applied. Removal attempts were made for 150 leads, 110 in ventricular and 40 in atrial positions. <jats:italic>Results<\/jats:italic>: Complete removal was possible in 122 cases (81 %). Partial removal was possible in 18 cases (12%). Failure to remove the lead with the extraction stylet was experienced in 10 cases (7%). In seven patients, the leads were removed by cardiothoracic surgery; 3 defective leads were left in place. There were no serious complications associated with the procedure. None of the patients died. <jats:italic>Conclusion<\/jats:italic>: The experience with this extraction stylet for lead removal has shown good results. Despite a low complication rate thus far, each case for lead removal should be judged on the individual basis of benefit\u2010to\u2010risk ratio.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1996.tb04786.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T16:41:01Z","timestamp":1151858461000},"page":"18-25","source":"Crossref","is-referenced-by-count":44,"title":["<b>Three\u2010Year Experience with a Stylet for Lead Extraction<\/b>: A Multicenter Study"],"prefix":"10.1111","volume":"19","author":[{"given":"ECKHARD","family":"ALT","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00d6RG","family":"NEUZNER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LUDWIG","family":"BINNER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KONRAD","family":"G\u00d6HL","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOHAN C.J.","family":"RES","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ULF\u2010HEINRICH","family":"KNABE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MANFRED","family":"ZEHENDER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00d6RG","family":"REINHARDT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(84)80248-X"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(69)90195-1"},{"key":"e_1_2_1_4_2","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/S0022-5223(19)41358-5","article-title":"Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode","volume":"74","author":"Lee M","year":"1977","journal-title":"J Thorac Cardivasc Surg"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(79)90284-9"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)36193-8"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1070922"},{"key":"e_1_2_1_8_2","first-page":"393","article-title":"Sepsis hei infiziertem Schrittmachersystem: Entfernung der endokardialen Sonde mit Hilfe der extrakorporalen Zirkulation","volume":"26","author":"Beyer J","year":"1978","journal-title":"Thoraxchirurgie"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb02348.x"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01581.x"},{"key":"e_1_2_1_11_2","first-page":"50","article-title":"Development of a technique for explantation of chronic transvenous pacemaker leads: Five initial case studies","volume":"25","author":"Goode LB","year":"1991","journal-title":"Biomed Instr Tech"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06905.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06906.x"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(90)90934-S"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb02345.x"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb04063.x"},{"key":"e_1_2_1_17_2","first-page":"A29","article-title":"Removal of electrode fragments by a transvenous snareloop catheter, (abstract)","volume":"4","author":"Alt E","year":"1981","journal-title":"PACE"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb02347.x"},{"key":"e_1_2_1_19_2","first-page":"29","volume-title":"New Perspectives in Cardiac Pacing","author":"Byrd CL","year":"1993"},{"key":"e_1_2_1_20_2","first-page":"513","article-title":"Intravascular lead extraction: Multicenter update for 523 patients, (abstract)","volume":"15","author":"Wilkoff BL","year":"1992","journal-title":"PACE"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02159.x"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(91)90203-T"},{"key":"e_1_2_1_23_2","first-page":"513","article-title":"Intravascular extraction of chronic pacing leads: The effect of physician experience, (abstract)","volume":"15","author":"Smith HJ","year":"1992","journal-title":"PACE"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb02325.x"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)36615-2"},{"key":"e_1_2_1_26_2","first-page":"3","article-title":"Warich\u2010Eitel S. Ausripfestigkeit von Schrittmacherelektroden aus dem Endomyocard","volume":"44","author":"Brunner P","year":"1992","journal-title":"Versicherungsmedizin"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1996.tb04786.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1996.tb04786.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,26]],"date-time":"2023-10-26T16:51:53Z","timestamp":1698339113000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1996.tb04786.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1996,1]]}},"alternative-id":["10.1111\/j.1540-8159.1996.tb04786.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1996.tb04786.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,1]]}}}