{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T12:15:58Z","timestamp":1763036158723},"reference-count":34,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":3286,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1997,7]]},"abstract":"<jats:p>A new type of endocardial bipolar pacing lead has been designed to overcome the potential drawbacks of the conventional coaxial bipolar pacing had. We prospectively evaluated the new co\u2010radial bipolar pacing leads (Intermedics Thin Line), which are thinner (5 Fr vs 6\u20148 Fr) than standard coaxial bipolar leads. X\u2010ray visibility and lead handling were subjectively assessed (excellent, good, adequate, or poor) at implant; lead impedance, sensitivity threshold, and pacing threshold were measured at implant, then at 1, 3. 6, 12, and 18 months. The results were as follows: 103 patients (51 M; age 63.8 \u00b1 17.4 years) received 71 atrial (A) and 89 ventricular (V) leads. X\u2010ray visibility was excellent in 59\/103; good in 23\/103; adequate in 11\/103; and poor in 10\/103. Overall handling was excellent in 56\/71 A and 69\/89 V; good in 11\/71 A and 18\/89 V; adequate in 3\/71 A and 1\/89 V; poor in 1\/71 A and 1\/89 V. There were two perioperative complications. At implant: impedance in A and V were 370.1 \u00b1 74.7 and 501.5 \u00b1 124.4 \u03a9, sensing thresholds in A and V were 3.0 \u00b1 1.5 and 9.9 \u00b1 5.0 mV, pacing thresholds at 0.45 ms in A and V were 0.59 \u00b1 0.21 and 0.41 \u00b1 0.15 volt, respectively. At 1, 3, 6. 12, and 18 months of follow\u2010up: no pacing lead related complications were reported; pacing lead characteristics remained outstanding and stable. This new lead appears to have significant clinical advantages over the conventional coaxial bipolar pacing lead. Long\u2010term follow\u2010up is required to confirm its reliability and chronic performance characteristics.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1997.tb03570.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T18:17:21Z","timestamp":1151864241000},"page":"1800-1807","source":"Crossref","is-referenced-by-count":15,"title":["Initial Experience with a Co\u2010Radial Bipolar Pacing Lead"],"prefix":"10.1111","volume":"20","author":[{"given":"CHUEN","family":"TANG","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOHN A.","family":"YEUNG\u2010LAI\u2010WAH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANZHEN","family":"QI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PAULINE","family":"MILLS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JACQUELINE","family":"CLARK","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FRANK","family":"TYERS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb02887.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb05300.x"},{"key":"e_1_2_1_4_2","first-page":"107","article-title":"High threshold exit block with stiff bipolar ventricular pacing leads","volume":"12","author":"Kertes P","year":"1990","journal-title":"Cardiostim 90, Nice, RBM"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06916.x"},{"key":"e_1_2_1_6_2","first-page":"748","article-title":"A possible new complication of subclavian stick: Conductor fracture","volume":"10","author":"Stokes K","year":"1987","journal-title":"PACE"},{"key":"e_1_2_1_7_2","first-page":"510","article-title":"Anatomic evaluation of pacemaker lead compression","volume":"15","author":"Fink AS","year":"1992","journal-title":"PACE"},{"key":"e_1_2_1_8_2","first-page":"571","article-title":"Does the venous route used for lead placement effect the incidence of lead failure","volume":"15","author":"Irwin M","year":"1992","journal-title":"(abstract) PACE"},{"key":"e_1_2_1_9_2","first-page":"572","article-title":"Malfunction of a coaxial bipolar pacing lead","volume":"15","author":"Zimmern S","year":"1992","journal-title":"PACE"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb01351.x"},{"key":"e_1_2_1_11_2","first-page":"27","volume-title":"Medtronic News XVI","author":"Subclavian puncture may result in lead conductor fracture","year":"1986"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1992.tb03007.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(68)90078-4"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)40179-7"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/13.7.383"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.56.5.750"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1985.tb05750.x"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1982.tb02185.x"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.36.1.77"},{"key":"e_1_2_1_20_2","first-page":"678","article-title":"Bipolar and unipolar permanent pacing leads\u2014which is superior","volume":"12","author":"Mond H","year":"1989","journal-title":"(abstract) PACE"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1984.tb05680.x"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb06912.x"},{"issue":"3","key":"e_1_2_1_23_2","first-page":"145","article-title":"Long term performance of silicone insulated and poly\u2010urethane insulated cardiac pacing leads","volume":"44","author":"Sethi KK","year":"1991","journal-title":"Indian Heart Journal"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0733-8651(18)30650-7"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04383.x"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1979.tb05216.x"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1982.tb02273.x"},{"key":"e_1_2_1_28_2","first-page":"47","article-title":"Clinical performance of a pacing lead with a platinized target\u2010tip electrode","volume":"7","author":"Heinemann F","year":"1984","journal-title":"PACE"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1979.tb05174.x"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1982.tb02193.x"},{"key":"e_1_2_1_31_2","first-page":"A","article-title":"Chronic thresholds with carbon tip endocardial leads","volume":"4","author":"Beck\u2010Junsen P.","year":"1981","journal-title":"PACE"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04385.x"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb06697.x"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb06304.x"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01709.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1997.tb03570.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1997.tb03570.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T03:18:01Z","timestamp":1698463081000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1997.tb03570.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,7]]},"references-count":34,"journal-issue":{"issue":"7","published-print":{"date-parts":[[1997,7]]}},"alternative-id":["10.1111\/j.1540-8159.1997.tb03570.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1997.tb03570.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,7]]}}}