{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T15:13:16Z","timestamp":1698505996293},"reference-count":15,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":3224,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1997,9]]},"abstract":"<jats:p>The relationship between the pacemaker sensitivity safety factor (PSSF) and atrial under\u2010 or oversensing as documented by 24\u2010hour Holter monitoring was examined. Our study comprised 78 transvenous fixed atrial leads implanted between 1983\u20131995 in 71 children. Overall, 210 Holter reports identified 143 (68%) Holters with normal atrial sensing function, 31 (15%) with undersensing, 32 (15%) with oversensing, and 4 (2%) with both problems. From 161 Holter reports in which the PSSF was available, the incidence of undersensing at a PSSF of 2.0 (range 1.5\u20132.4) was 25% (14\/57). There was a dramatic decline in undersensing when the PSSF was  3 (3%) compared to a FSSF &lt; 3 (21 %) (P &lt; 0.001). A PSSF cut\u2010off point of 2.0 best predicted occurrence of undersensing with a sensitivity of 79% and a specificity of 67%. Other variable were also examined by multiple logistic regression analysis, but only PSSF remained highly associated with undersensing (odds ratio [OR] = 0.6, P = 0.03). In contrast, PSSF did not have a significant role in predicting oversensing, but presence of sick sinus syndrome (OR = 10.5) or unipolar lead (OR = 5.6) were significantly associated with oversensing (P = 0.0001). The majority of undersensing problems can be avoided by routinely allowing for at least a threefold or more programmed sensitivity margin. Other factors may increase the risk of oversensing, regardless of the PSSF.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1997.tb04232.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T18:24:06Z","timestamp":1151864646000},"page":"2163-2170","source":"Crossref","is-referenced-by-count":4,"title":["Impact of Programmed Sensitivity Safety Factor on Atrial Sensing in Children"],"prefix":"10.1111","volume":"20","author":[{"given":"CHRISTINE C.","family":"CHIU","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ROBERT M.","family":"GOW","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"BRIAN W.","family":"McCRINDLE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ROBERT M.","family":"HAMILTON","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb02823.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90615-T"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1982.tb02262.x"},{"issue":"1","key":"e_1_2_1_5_2","first-page":"l","article-title":"Stimulation and sensing thresholds for cardiac pacing; Electrophysiologic and technical aspects","volume":"24","author":"Barold SS","year":"1981","journal-title":"Progr Cardiovasc Dis"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03767.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb03929.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1985.tb05877.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(88)90215-X"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb06479.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01866.x"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03766.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03761.x"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(85)80222-9"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(94)90641-6"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb05069.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1997.tb04232.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1997.tb04232.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T18:37:53Z","timestamp":1698431873000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1997.tb04232.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,9]]},"references-count":15,"journal-issue":{"issue":"9","published-print":{"date-parts":[[1997,9]]}},"alternative-id":["10.1111\/j.1540-8159.1997.tb04232.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1997.tb04232.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,9]]}}}