{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T16:16:39Z","timestamp":1772036199251,"version":"3.50.1"},"reference-count":26,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,6,14]],"date-time":"2006-06-14T00:00:00Z","timestamp":1150243200000},"content-version":"vor","delay-in-days":3451,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1997,1]]},"abstract":"<jats:p>The ICD has become a standard treatment for patients with malignant arrhythmias. Despite its benefits it may cause additional discomfort to the patients. Thus, quality\u2010of\u2010life needs to be assessed in these patients. Previous studies have used only small samples or unstandardized measures of quality\u2010of\u2010life that do not allow comparisons with other patient groups. The present study used standardized questionnaires for a cross\u2010sectional assessment of psychological well\u2010being and quality\u2010of\u2010life in ICD patients and to compare them to a similar group of coronary artery disease (CAD) patients without ICD. Overall, quality\u2010of life did not differ between both groups, ICD patients being less anxious than the CAD group. With increasing numbers of ICD shocks, however, the percentage of psychologically distressed ICD patients rose from 10% to &gt; 50%. Psychologically distressed patients had significantly worse scores on most of the quality\u2010of\u2010life subscales, showed less treatment satisfaction, and more negative attitudes. It is concluded that ICD patients have an acceptable mean quality\u2010of\u2010life and low mean anxiety. However, a relevant subgroup of about 15%, especially patients with frequent shocks, experience psychological distress and reduced quality\u2010of\u2010life and should receive special care.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1997.tb04817.x","type":"journal-article","created":{"date-parts":[[2006,6,14]],"date-time":"2006-06-14T10:08:02Z","timestamp":1150279682000},"page":"95-103","source":"Crossref","is-referenced-by-count":110,"title":["Standardized Assessment of Psychological Well\u2010Being and Quality\u2010of\u2010Life in Patients with Implanted Defibrillators"],"prefix":"10.1111","volume":"20","author":[{"given":"CHRISTOPH","family":"HERRMANN","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FRIEDERIKE","family":"von zur M\u00dcHEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANSELM","family":"SCHAUMANN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ULLRICH","family":"BUSS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SYLKE","family":"KEMPER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTIAN","family":"WANTZEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"BERND\u2010DIETER","family":"GONSKA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,14]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(89)90457-2"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb02670.x"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.3949\/ccjm.57.5.441"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb05088.x"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1059327"},{"issue":"3","key":"e_1_2_1_7_2","first-page":"32","article-title":"Angstverhalten bei Patienten mit implantierbarem Kardioverter\u2010Defibrillator. (abstract)","volume":"82","author":"Jung W","year":"1993","journal-title":"Z Kardiol"},{"key":"e_1_2_1_8_2","first-page":"I\u2010499","article-title":"Quality of life in ICD Recipients","volume":"90","author":"Jung W","year":"1994","journal-title":"Circulation"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01816.x"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(94)90107-4"},{"key":"e_1_2_1_11_2","first-page":"927","article-title":"Acceptance and quality of life after implantation of the automatic cardioverter defibrillator","volume":"83","author":"Sch\u00f6hl W","year":"1994","journal-title":"Z Kardiol"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0447.1983.tb09716.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(85)90805-0"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.69.5.382"},{"key":"e_1_2_1_15_2","first-page":"264","article-title":"Relationships of cardiological findings and standardized psychological self\u2010ratings to clinical symptoms in 3.705 patients referred for exercise testing","volume":"83","author":"Herrmann Ch","year":"1994","journal-title":"Z Kardiol"},{"key":"e_1_2_1_16_2","first-page":"864","article-title":"A randomized crossover study to assess the efficacy of group counselling in patients with implantable cardioverter defibrillators","volume":"17","author":"Barakat K","year":"1994","journal-title":"PACE"},{"key":"e_1_2_1_17_2","first-page":"353","article-title":"Ein Fragebogen zur Erfassung der Lebensqualit\u00e4t\u2010erste teststatistische Ergebnisse am Beispiel von Hypertonikern","volume":"36","author":"Junge A","year":"1990","journal-title":"Diagnostica"},{"key":"e_1_2_1_18_2","unstructured":"SiegristJ 3 September 1991 personal communication."},{"key":"e_1_2_1_19_2","volume-title":"Profil der Leben\u2010squalit\u00e4t Chronischkranker (PLC) Testhandbuch","author":"Siegrist J","year":"1995"},{"issue":"1","key":"e_1_2_1_20_2","article-title":"Vorhersage der Lebensqualit\u00e4t m\u00e4nnlicher Postinfarktpatienten mit koronarer 3\u2010Gef\u00e4\u2010Erkrankung","volume":"84","author":"Herrmann C","year":"1995","journal-title":"Z Kardiol"},{"key":"e_1_2_1_21_2","volume-title":"Leben\u2010squalit\u00e4t bei kardiovaskul\u00e4ren Erkrankungen","author":"Bullinger M","year":"1991"},{"key":"e_1_2_1_22_2","first-page":"238","article-title":"Observations of a support group for automatic implantable cardioverter\u2010defibrillator recipients and their spouses","volume":"18","author":"Badger JM","year":"1989","journal-title":"Heart Lung"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005082-199002000-00006"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3999(90)90080-N"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0033-3182(93)71821-6"},{"key":"e_1_2_1_26_2","first-page":"35","article-title":"Role of antitachycardia pacing in patients with third\u2010generation cardioverter\u2010defibrillators","volume":"84","author":"Trappe HJ","year":"1995","journal-title":"Z Kardiol"},{"key":"e_1_2_1_27_2","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1111\/j.1540-8159.1995.tb02603.x","article-title":"The impact of the implantable cardioverter defibrillator on quality\u2010of\u2010life","volume":"18","author":"May CD","year":"1995","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1997.tb04817.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1997.tb04817.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T16:21:56Z","timestamp":1698423716000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1997.tb04817.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,1]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1997,1]]}},"alternative-id":["10.1111\/j.1540-8159.1997.tb04817.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1997.tb04817.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,1]]}}}