{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:31:04Z","timestamp":1761561064221},"reference-count":28,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,6,14]],"date-time":"2006-06-14T00:00:00Z","timestamp":1150243200000},"content-version":"vor","delay-in-days":3451,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1997,1]]},"abstract":"<jats:p>Recent studies have shown that internal cardioversion of atrial fibrillation is safe and effective. In this randomized prospective study, we have tried to evaluate the influence of different waveforms on the perception of pain during internal cardioversion in patients with chronic atrial fibrillation. Methods: Internal cardioversion was performed with minimal or no sedation in 31 consecutive patients, R wave triggered, biphasic shocks of 6 ms\/6 ms or 3 ms\/3 ms duration (randomly selected) and approximately 65% tilt were used starting with a 50\u2010V test shock. The shock intensity was increased in 40\u2010V steps up to a maximum voltage of 520 V. Shocks were applied via two custom\u2010made catheters (Elecath, Rahway, NJ). In 16 patients (3 females, age 61 \u00b1 11 years, left atrium diameter 58 \u00b1 5 mm, duration of atrial fibrillation 4 \u00b1 4 months), 6\/6 waveforms were used, and in 15 patients (1 female, age 62 \u00b1 5 years, left atrium diameter 59 \u00b1 4 mm, duration of atrial fibrillation 5 \u00b1 2 months), 3\/3 waveforms were used. After cardioversion, each patient was asked to quantify their pain on a scale from 0\u201310 (0 = no pain, 10 = intolerable). Fourteen of the 15 patients in the 3\/3 ms and 15 of the 16 patients in the 6\/6 ms group were successfully cardioverted. Patients from the 6\/6 waveform group were cardioverted with a lower mean voltage of 254\/92 versus 355\/127 V (P &lt; 0.02), at lower pain score 1.8 \u00b1 1.3 versus 4.2 \u00b1 2.2 (P &lt; 0.05) with equivalent energy (6.8 \u00b1 2.8 versus 6.2 \u00b1 1.5 J, n.s.) and required lower doses of midazolam of 2.2 \u00b1 1.9 versus 4.0 \u00b1 1.8 mg IV (P &lt; 0.02). The waveform used in internal cardioversion seems to have a major impact on the patients\u2019 perception of pain. These results imply that energy determines the success of a shock, but voltage determines the pain perceived by the patient. The use of waveforms that deliver greater energy at lower peak voltages offers the possibility of internal cardioversion with less sedation and greater patient tolerance.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1997.tb04849.x","type":"journal-article","created":{"date-parts":[[2006,6,14]],"date-time":"2006-06-14T10:08:02Z","timestamp":1150279682000},"page":"230-236","source":"Crossref","is-referenced-by-count":44,"title":["Pain Threshold for Low Energy Intracardiac Cardioversion of Atrial Fibrillation with Low or No Sedation"],"prefix":"10.1111","volume":"20","author":[{"given":"RICHARD","family":"AMMER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ECKHARD","family":"ALT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GREGORY","family":"AYERS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CLAUS","family":"SCHMITT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JAY","family":"PASQUANTONIO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MATTHIAS","family":"SCHMIDT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KATJA","family":"P\u00dcTTER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALBERT","family":"SCH\u00d6MIG","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,14]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198204293061703"},{"key":"e_1_2_1_3_2","first-page":"41A","article-title":"Hospitalization for arrhythmias in the United States: Importance of atrial Fibrillation","volume":"19","author":"Bialy D","year":"1992","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199412013312211"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.82.4.1106"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.80.6.1557"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.82.6.1932"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0954-6820.1988.tb15764.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-65-2-216"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.86.5.1415"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.52.4.377"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)90610-2"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.87.5.1673"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90028-L"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb01462.x"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.89.1.413"},{"key":"e_1_2_1_17_2","first-page":"I\u201014","article-title":"Safety of low energy transvenous atrial defibrillation\u2010world experience","volume":"90","author":"Murgatroyd F","year":"1994","journal-title":"Circulation"},{"key":"e_1_2_1_18_2","first-page":"60","article-title":"Intracardiac low energy conversion of atrial fibrillation compared to external conversion: Results and follow\u2010up","volume":"18","author":"Alt E","year":"1995","journal-title":"PACE"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(96)00274-4"},{"key":"e_1_2_1_20_2","first-page":"633","article-title":"Effect of different right atrial lead locations on the efficacy and tolerability of low energy transvenous atrial defibrillation with an implantable lead system, (abstract)","volume":"19","author":"Lok NS","year":"1996","journal-title":"PACE"},{"key":"e_1_2_1_21_2","first-page":"911","article-title":"Comparison of pulmonary artery vs. coronary sinus lead position for low energy conversion of atrial fibrillation. (abstract)","volume":"65","author":"Alt E","year":"1995","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.81.4.1252"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.92.6.1627"},{"key":"e_1_2_1_24_2","first-page":"125A","article-title":"Clinical efficacy and safety of atrial defibrillation using current nonthoracotomy endocardial lead configurations: A prospective randomized study, (abstract)","volume":"23","author":"Saksena S","year":"1994","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_25_2","first-page":"211","volume-title":"Atrial fibrillation: Mechanisms and Therapeutic Strategies","author":"Waldo AL","year":"1994"},{"key":"e_1_2_1_26_2","first-page":"125A","article-title":"Successful atrial defibrillation using temporary pericardial electrodes. (abstract)","volume":"23","author":"Ortiz J","year":"1994","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_27_2","unstructured":"SchmittC PlewanA KarchM et al.Intraatrial defibrillation for cardioversion of atrial fibrillation complicating radiofrequency ablation of accessory pathways(data on file)."},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.87.5.1769"},{"key":"e_1_2_1_29_2","first-page":"769","article-title":"An implantable atrial defibrillator: Initial animal experience with a novel device, (abstract)","volume":"17","author":"Ayers GM","year":"1994","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1997.tb04849.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1997.tb04849.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T16:23:12Z","timestamp":1698423792000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1997.tb04849.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,1]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1997,1]]}},"alternative-id":["10.1111\/j.1540-8159.1997.tb04849.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1997.tb04849.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,1]]}}}