{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T05:04:02Z","timestamp":1698555842121},"reference-count":6,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T00:00:00Z","timestamp":1151625600000},"content-version":"vor","delay-in-days":3102,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[1998,1]]},"abstract":"<jats:p>Malfunction of a pacing system can be life\u2010threatening for a pacemaker\u2010dependent patient. It would be desirable for implantable pulse generators to have a built\u2010in automatic warning system capable of alerting the patient m soon as a potentially dangerous disorder is detected. In this study, seven patients (mean age, 72.6 \u00b1 10.7 years) with slow, chronic atrial fibrillation underwent implantation of a dual\u2010chamber pulse generator with a atstom\u2010made \u201calert electrode\u201d connected to the atrial port of the pulse generator to stimulate the underlying pectoral muscle. The muscle was temporarily stimulated while the pacemaker was in VVIR mode. The lowest amplitude sufficient to alert the patient (perception threshold) was 1.6 \u00b1 0.58 V at 0.45 ms during implantation and 1.2 \u00b1 0.5 V at 0.45 ms chronically. In a second phase, alerts outside of the office were issued using a special software routine capable of delivering stimuli at programmable date and time.<\/jats:p>","DOI":"10.1111\/j.1540-8159.1998.tb01099.x","type":"journal-article","created":{"date-parts":[[2006,7,2]],"date-time":"2006-07-02T18:36:07Z","timestamp":1151865367000},"page":"256-259","source":"Crossref","is-referenced-by-count":2,"title":["The Patient Alert System \u2010 Pilot Study of Built\u2010in Warning Systems for Pacemakers"],"prefix":"10.1111","volume":"21","author":[{"given":"THOMAS","family":"FAHRAEUS","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LARRY","family":"STOTTS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DAVID","family":"PRUTCHI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"STEVEN","family":"MAERTENS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DRURY","family":"WOODSON","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DANIEL","family":"COOKE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1995.tb04740.x"},{"key":"e_1_2_1_3_2","unstructured":"Medtronic.Product Performance Report. Spring1996 p.6\u20137."},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1992.tb03008.x"},{"key":"e_1_2_1_5_2","unstructured":"Danish Pacemaker Register1995 p.17."},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01918.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1996.tb03232.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.1998.tb01099.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.1998.tb01099.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T13:37:07Z","timestamp":1698500227000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.1998.tb01099.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,1]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1998,1]]}},"alternative-id":["10.1111\/j.1540-8159.1998.tb01099.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.1998.tb01099.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[1998,1]]}}}