{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:57:37Z","timestamp":1778824657268,"version":"3.51.4"},"reference-count":14,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2339,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,2]]},"abstract":"<jats:p>Because oxygen uptake (VO<jats:sub>2<\/jats:sub>) increases linearly with heart rate during exercise, the oxygen pulse reserve (OPR) method (VO<jats:sub>2<\/jats:sub> reserve divided by heart rate reserve) may provide a valid guide for rate responsive parameter tailoring. Using custom\u2010made software (Pacing Rate Profile Software [PRPS]) it is possible to predict the exercise pacing rate profile with significant accuracy, according to the patient's functional class when ergospirometry apparatus is not available for a cardiopulmonary stress test (CPX). PRPS for Windows is based on the OPR method and some known workload\/metabolic cost of exercise relationships during effort. The present study had two aims; first, to evaluate the reliability of PRPS in accurately predicting pacing rate profiles; and second, the suitability of activity and metabolic rate responsive sensors in supplying pacing rates sufficiently near to those predicted using CPX or PRPS. To test the reliability of PRPS we studied 244 patients, NYHA Class I\u2010II, under two different stress test protocols. In one, the bicycle protocol (25 W, 2\u2010minute steps), we tested 137 normal patients (94 men and 43 women, mean age 67 \u00b1 15 years). Sixty\u2010eight of these were simultaneously CPX tested. PRPS predicted pacing rates were matched against the patients' sinus rhythms or their theoretical CPX measured VO<jats:sub>2<\/jats:sub> heart rates (OPR method). Linear regression analysis was highly significant (r = 0.93 and r = 0.97, respectively). The other, the treadmill protocol, consisted of three different protocols. (1) Speed Incremental Treadmill Stress Test (SITST): 57 patients underwent CPX (33 men and 24 women, mean age 67 \u00b1 15 years, NYHA Class I\u2010II). All had been pacemaker implanted for SSS and\/or advanced atrioventricular block (AVB). PRPS pacing rates were matched against CPX VO<jats:sub>2<\/jats:sub> OPR calculated heart rates (r = 0.93), (linear regression analysis). (2) CAEP: 30 patients underwent CPX (26 men and 4 women, mean age 61 \u00b1 11 years, NYHA Class I\u2010II). Thirteen of them had been pacemaker implanted for SSS and\/or advanced AVB. In all 30 patients the PRPS rates were matched against CPX VO<jats:sub>2<\/jats:sub> calculated rates (r = 0.90). In the 17 normal nonimplanted patients, the PRPS rates were also matched against sinus rhythms, (r = 0.80). (3) Weber: 20 patients underwent CPX (16 men and 4 women, mean age 68 \u00b1 8 years, NYHA Class I\u2010II). As above, in six normal nonimplanted patients, statistical analysis between PRPS rates and sinus rhythms was performed (r = 0.89). The comparison between PRPS theoretical pacing rates and VO<jats:sub>2<\/jats:sub> predicted rates in all 20 patients was also statistically significant (r = 0.93). Finally, to test the reliability of PRPS also in NYHA Class III\u2010IV patients, we tested 22 implanted patients (15 men and 7 women, mean age 70 \u00b1 9 years) and compared PRPS predicted rates against VO<jats:sub>2<\/jats:sub> CPX measured rates (r = 0.92). To determine if the wide variety of RR pacers were able to supply pacing rates near to those predicted, whether by means of CPX or PRPS, we studied a total of 89 patients: 49 of these (26 men and 23 women, mean age 66 \u00b1 12 years) had been implanted with activity sensors; 12 patients (11 men and one woman, mean age 70 \u00b1 7 years) had been implanted with metabolic sensors, and finally 28 patients (19 men and 9 women, mean age 70 \u00b1 12 years) had been implanted with dual sensors (activity + QT or minute ventilation). Linear regression analysis showed r = 0.93 for activity sensors, r = 0.94 for metabolic sensors, and r = 0.92 for dual sensor. In conclusion, when rate responsive pacing causes symptoms or functional impairment, physicians must provide a personalized rate response tailoring derived from precise, simple physiological testing. OPR is an easy physiological method for tailoring rate response settings, suitable for activity and metabolic sensors. When ergospirometry apparatus is not available, PRPS can successfully replace CPX testing for tailoring.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00797.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:24:17Z","timestamp":1151508257000},"page":"165-173","source":"Crossref","is-referenced-by-count":6,"title":["How to Program Rate Responsive Pacemakers"],"prefix":"10.1111","volume":"23","author":[{"given":"ENRICO MARIA","family":"GRECO","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SILVIA","family":"GUARDINI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARCO","family":"FERRARIO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SALVATORE","family":"ROMANO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-72367-4_39"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04478.x"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04398.x"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1984.tb05691.x"},{"key":"e_1_2_1_6_2","first-page":"244","article-title":"Reliability of right ventricular impedance as a biological sensor in dual chamber rate responsive pacing","volume":"3","author":"Occhetta E","year":"1993","journal-title":"Eur JCPE"},{"key":"e_1_2_1_7_2","volume-title":"Exercise Physiology: Theory and Application to Fitness and Performance","author":"Powers SG","year":"1990"},{"key":"e_1_2_1_8_2","first-page":"29","article-title":"Determinants and detection of anaerobic threshold and consequences of exercise above it","volume":"76","author":"Wasserman K.","year":"1987","journal-title":"Circulation"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/140.5.1373"},{"key":"e_1_2_1_10_2","first-page":"72","article-title":"La riabili\u2010tazione cardiologica nel paziente anziano porta\u2010tore di pacemaker rate responsive","author":"Greco EM","year":"1995","journal-title":"Giornale di ri-abilitazione"},{"key":"e_1_2_1_11_2","first-page":"152","volume-title":"Cardiopulmonary Exercise Testing: Physiologic Principles and Clinical Application","author":"Weber KT","year":"1986"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1989.tb01549.x"},{"key":"e_1_2_1_13_2","volume-title":"Guidelines for Exercise Stress Testing and Prescription","year":"1986"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb01895.x"},{"key":"e_1_2_1_15_2","first-page":"1301","article-title":"Is accurate rate response programming necessary","volume":"3","author":"Sulke N","year":"1990","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00797.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00797.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T07:50:27Z","timestamp":1698565827000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00797.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,2]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2000,2]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00797.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00797.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,2]]}}}